Short Dental Implants versus Standard Dental Implants Placed in The Posterior Jaws

Esam Eshaweirf, Abdesalam Sougei
{"title":"Short Dental Implants versus Standard Dental Implants Placed in The Posterior Jaws","authors":"Esam Eshaweirf, Abdesalam Sougei","doi":"10.21608/ijma.2023.227855.1767","DOIUrl":null,"url":null,"abstract":"Article information Background: Recent studies have revealed that the utilization of shorter dental implants generally represents the optimal approach for addressing the majority of instances involving bone loss in the posterior region of the oral cavity. Short implants have superior performance and exhibit a reduced incidence of complications compared to lengthier implants. Aim of the work: The aim of this study is to conduct a comparative analysis of smaller dental implants and standard dental implants specifically employed in the posterior region of the oral cavity. Patients and Methods: A research study was conducted at an affiliated dental clinic, focusing on adult patients. The study utilized Biomimetic Ocean implants with internal hex connections manufactured by Avinent Implant System, Spain. Two sizes of implants were used, regular implants measuring 10 mm and short implants measuring 7 mm. The sample size was 60 Patients. A total of 29 standard implants and 17 short implants were put. The methods involved comprehensive ethical considerations, obtaining informed consent from participants, and thorough examinations at multiple time points. Surgical and prosthetic procedures were performed, and clinical examinations, radiographic measurements, and stability assessments were conducted. Statistical analysis was employed to analyze the collected data. Results: The results indicate that all of the implants in both groups were effective. Following the surgical procedure, it was observed that the Standard Implants Group exhibited a comparatively higher mean initial stability quotient [ISQ] score of 77.1 ± 65, whereas the Short Implants Group displayed a mean ISQ score of 71.7 ± 81. This discrepancy in ISQ values between the two groups during the visit is noteworthy. Both groups had comparable mean ISQ values during the subsequent surgical procedure. Conclusion: The findings of this study indicate that shorter implants demonstrate","PeriodicalId":53130,"journal":{"name":"International Journal of Medical Arts","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Arts","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/ijma.2023.227855.1767","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Article information Background: Recent studies have revealed that the utilization of shorter dental implants generally represents the optimal approach for addressing the majority of instances involving bone loss in the posterior region of the oral cavity. Short implants have superior performance and exhibit a reduced incidence of complications compared to lengthier implants. Aim of the work: The aim of this study is to conduct a comparative analysis of smaller dental implants and standard dental implants specifically employed in the posterior region of the oral cavity. Patients and Methods: A research study was conducted at an affiliated dental clinic, focusing on adult patients. The study utilized Biomimetic Ocean implants with internal hex connections manufactured by Avinent Implant System, Spain. Two sizes of implants were used, regular implants measuring 10 mm and short implants measuring 7 mm. The sample size was 60 Patients. A total of 29 standard implants and 17 short implants were put. The methods involved comprehensive ethical considerations, obtaining informed consent from participants, and thorough examinations at multiple time points. Surgical and prosthetic procedures were performed, and clinical examinations, radiographic measurements, and stability assessments were conducted. Statistical analysis was employed to analyze the collected data. Results: The results indicate that all of the implants in both groups were effective. Following the surgical procedure, it was observed that the Standard Implants Group exhibited a comparatively higher mean initial stability quotient [ISQ] score of 77.1 ± 65, whereas the Short Implants Group displayed a mean ISQ score of 71.7 ± 81. This discrepancy in ISQ values between the two groups during the visit is noteworthy. Both groups had comparable mean ISQ values during the subsequent surgical procedure. Conclusion: The findings of this study indicate that shorter implants demonstrate
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
短牙种植体与后颌标准牙种植体的比较
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
85
审稿时长
12 weeks
期刊最新文献
Unilateral Stereotactic Radiofrequency Thalamotomy for Tremors in Parkinson’s Patients Study of Early versus Delayed Oral Fluid and Food after Cesarean Section Comparative Study Between the Outcomes of Laparoscopic Sleeve Gastrectomy and Mini Gastric Bypass for Morbidly Obese Patients Effect of Resistance Training on Physical Performance in Underweight Females Efficacy of Topical Latanoprost Versus Topical Minoxidil In the Treatment of Alopecia Areata: Clinical and Dermoscopic Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1