German Vasilevich Pachurin, Nikolay Aleksandrovich Kuzmin, Maria Vadimovna Mochalina, Alexey Aleksandrovich Filippov
{"title":"Effect Produced by the Treatment Type on the Performance of the Artificial Heart Valve Welded Frame","authors":"German Vasilevich Pachurin, Nikolay Aleksandrovich Kuzmin, Maria Vadimovna Mochalina, Alexey Aleksandrovich Filippov","doi":"10.2174/2405520416666230809124226","DOIUrl":null,"url":null,"abstract":"Background: The welded joint loss of performance is largely determined by the heterogeneity of the structural state of the heat-affected zones. The basic materials from which the artificial heart valve welded frames are made are technically pure titanium grade VT1-OS and alloy grade 40 KHNM with the required biomedical properties. Objective: The study of the structural state, and changes in mechanical characteristics under static and cyclic loading of welded joints made of pure titanium grade VT1-OS and alloy grade 40 KHNM. Method: The paper investigates structural changes and mechanical characteristics under static and cyclic loading in Ringer-Locke saline solution of welded T-shaped joints made of pure titanium grade VT1-OS and alloy grade 40 KHNM, simulating the nodes of an artificial heart valve subject to maximum cyclic loads during operation. Result: It is revealed that the structural and mechanical heterogeneity along the length of the welded joints of the studied materials determines a loss of mechanical performance, both under static and cyclic loading. Conclusion: Experimental batches of welded elements of artificial heart valve assemblies made of VT1-OS titanium and 40 KHNM alloy according to the established optimal modes have successfully passed full-scale tests on physiological and biological stands in conditions as close as possible to the operational ones.","PeriodicalId":38021,"journal":{"name":"Recent Innovations in Chemical Engineering","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Recent Innovations in Chemical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/2405520416666230809124226","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Chemical Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The welded joint loss of performance is largely determined by the heterogeneity of the structural state of the heat-affected zones. The basic materials from which the artificial heart valve welded frames are made are technically pure titanium grade VT1-OS and alloy grade 40 KHNM with the required biomedical properties. Objective: The study of the structural state, and changes in mechanical characteristics under static and cyclic loading of welded joints made of pure titanium grade VT1-OS and alloy grade 40 KHNM. Method: The paper investigates structural changes and mechanical characteristics under static and cyclic loading in Ringer-Locke saline solution of welded T-shaped joints made of pure titanium grade VT1-OS and alloy grade 40 KHNM, simulating the nodes of an artificial heart valve subject to maximum cyclic loads during operation. Result: It is revealed that the structural and mechanical heterogeneity along the length of the welded joints of the studied materials determines a loss of mechanical performance, both under static and cyclic loading. Conclusion: Experimental batches of welded elements of artificial heart valve assemblies made of VT1-OS titanium and 40 KHNM alloy according to the established optimal modes have successfully passed full-scale tests on physiological and biological stands in conditions as close as possible to the operational ones.