COMPARISON OF IMMUNOCHROMATOGRAPHIC TEST NEGATIVE HEPATITIS B VIRUS AND HEPATITIS C VIRUS BLOOD DONATIONS WITH ELISA IN PUBLIC AND PRIVATE BLOOD BANKS OF LAHORE - PAKISTAN

{"title":"COMPARISON OF IMMUNOCHROMATOGRAPHIC TEST NEGATIVE HEPATITIS B VIRUS AND HEPATITIS C VIRUS BLOOD DONATIONS WITH ELISA IN PUBLIC AND PRIVATE BLOOD BANKS OF LAHORE - PAKISTAN","authors":"","doi":"10.54079/jpmi.37.3.3200","DOIUrl":null,"url":null,"abstract":"Objectives: To determine the frequency of immunochromatographic test for false negative HBV and HCV testing among healthy blood donors in Lahore - Pakistan. Methodology: This was 18 months cross sectional pilot study, conducted in private and public blood banks of city Lahore. After taking formal consent from head of selected Hospital and in charge blood bank/ donors, blood bags screened as HBs Ag and Anti HCV negative by immune-chromatographic (ICT) method, 3-5 ml blood was transferred to coded tube and later transferred to ex-PHRC research Centre NHRC Lahore, where plasma was separated through centrifugation and stored at -40/-20C. Collected samples from this Centre sent to ex-PHRC Research Centre Khyber Medical College Peshawar in cold chain for ELISA testing. Results: Study found that among 385 HBs Ag and anti HCV ICT negative Labeled blood bags 0.8 % was positive for HBs Ag and 2.1% blood bags was positive for anti HCV antibody on ELISA testing. Frequency of AB –ive and A-ive blood bags availability were very rare, 1 % for both types. False negative testing rate of blood bags was comparatively high in public sectors hospitals (1 % for HBs Ag and 3.2% for anti HCV) than private sector hospitals (0.5% for HBs Ag and 1% for anti HCV. False negative ICT testing rate was observed high among blood group B +ive (0.8% for HBV and 4.1% for HCV) than all other blood groups. Conclusion: Study found that 0.8% blood bags were screened falsely negative by immuno-chromatographic method (ICT) for HBs Ag and 2.1% for anti HCV.","PeriodicalId":16878,"journal":{"name":"Journal of Postgraduate Medical Institute","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Postgraduate Medical Institute","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54079/jpmi.37.3.3200","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To determine the frequency of immunochromatographic test for false negative HBV and HCV testing among healthy blood donors in Lahore - Pakistan. Methodology: This was 18 months cross sectional pilot study, conducted in private and public blood banks of city Lahore. After taking formal consent from head of selected Hospital and in charge blood bank/ donors, blood bags screened as HBs Ag and Anti HCV negative by immune-chromatographic (ICT) method, 3-5 ml blood was transferred to coded tube and later transferred to ex-PHRC research Centre NHRC Lahore, where plasma was separated through centrifugation and stored at -40/-20C. Collected samples from this Centre sent to ex-PHRC Research Centre Khyber Medical College Peshawar in cold chain for ELISA testing. Results: Study found that among 385 HBs Ag and anti HCV ICT negative Labeled blood bags 0.8 % was positive for HBs Ag and 2.1% blood bags was positive for anti HCV antibody on ELISA testing. Frequency of AB –ive and A-ive blood bags availability were very rare, 1 % for both types. False negative testing rate of blood bags was comparatively high in public sectors hospitals (1 % for HBs Ag and 3.2% for anti HCV) than private sector hospitals (0.5% for HBs Ag and 1% for anti HCV. False negative ICT testing rate was observed high among blood group B +ive (0.8% for HBV and 4.1% for HCV) than all other blood groups. Conclusion: Study found that 0.8% blood bags were screened falsely negative by immuno-chromatographic method (ICT) for HBs Ag and 2.1% for anti HCV.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
巴基斯坦拉合尔市公私血库免疫层析试验阴性乙型肝炎病毒和丙型肝炎病毒献血elisa比较
目的:了解巴基斯坦拉合尔健康献血者中HBV和HCV假阴性免疫层析检测的频率。方法:这是一项为期18个月的横断面试点研究,在拉合尔市的私人和公共血库进行。经选定医院负责人和主管血库/献血者的正式同意后,经免疫层析(ICT)方法筛选为HBs Ag和抗HCV阴性的血袋,将3-5 ml血液转移到编码管中,然后转移到前phrc研究中心NHRC拉合尔,在那里通过离心分离血浆并在-40/-20℃下保存。从该中心收集的样本经冷链送往前phrc研究中心白沙瓦开伯尔医学院进行酶联免疫吸附试验。结果:研究发现385例HBs Ag和抗HCV ICT阴性标记血袋中,ELISA检测HBs Ag阳性的占0.8%,抗HCV抗体阳性的占2.1%。AB -ive和A-ive血袋可用性的频率非常罕见,两种类型均为1%。公立医院血袋假阴性率(HBs抗原为1%,抗HCV为3.2%)高于私立医院(HBs抗原为0.5%,抗HCV为1%)。B +ive血型的ICT假阴性率(HBV为0.8%,HCV为4.1%)高于其他所有血型。结论:研究发现,HBs抗原免疫层析法(ICT)假阴性血袋检出率为0.8%,抗HCV检出率为2.1%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
37
期刊介绍: Information not localized
期刊最新文献
SITUS INVERSUS TOTALIS WITH UNILATERAL UNDESCENDED TESTIS: A CASE REPORT EPIDERMAL GROWTH FACTOR RECEPTOR OVEREXPRESSION IN TRIPLE NEGATIVE BREAST CANCER NON-ALCOHOLIC FATTY LIVER DISEASE IN OBESE CHILDREN: FREQUENCY, METABOLIC PROFILES, AND ASSOCIATED RISK FACTORS SPIRITUAL HEALING - A COMPETING OR CO-EXISTING SYSTEM TO ALLOPATHIC MEDICINE ROLE OF ASCORBIC ACID IN IMPROVING MOOD IN PATIENTS WITH DEPRESSION: A RANDOMIZED CONTROLLED TRIAL
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1