Prognostic Value of Jugular Venous Diameters and Compliance in Patients with Exacerbation of Chronic Obstructive Pulmonary Disease

IF 0.9 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Medical Ultrasound Pub Date : 2023-11-10 DOI:10.4103/jmu.jmu_83_23
Kutlu Barış Teke, Nurettin Özgür Doğan, İbrahim Ulaş Özturan, Serkan Yılmaz, Elif Yaka, Murat Pekdemir
{"title":"Prognostic Value of Jugular Venous Diameters and Compliance in Patients with Exacerbation of Chronic Obstructive Pulmonary Disease","authors":"Kutlu Barış Teke, Nurettin Özgür Doğan, İbrahim Ulaş Özturan, Serkan Yılmaz, Elif Yaka, Murat Pekdemir","doi":"10.4103/jmu.jmu_83_23","DOIUrl":null,"url":null,"abstract":"Abstract Background: Chronic obstructive pulmonary disease (COPD) exacerbations constitute a significant proportion of patients presenting to the emergency department (ED). It has been suggested that measurement of jugular venous diameter and compliance may have prognostic value in patients with heart failure. We hypothesized that these measurements may also be valuable in patients with advanced COPD. Methods: This study was a single-center, prospective, and cross-sectional study conducted in a university hospital between November 2020 and November 2021. In the study, internal jugular vein (IJV) diameters (inspiration, forced expiration, and rest) and jugular venous compliance were measured with ultrasound in patients who presented to the ED with COPD exacerbation. One month later, data about mortality, intensive care unit (ICU) admission, and any hospitalization were obtained and evaluated together with a range of laboratory parameters. Results: Data from a total of 93 patients were analyzed. Of these, 17 (18.2%) died, 19 (20.4%) were admitted to the ICU, and 36 (38.7%) were hospitalized at the end of the 1-month period. Consequently, a total of 44 patients (47.3%) were in the good outcome group and 49 patients (52.7%) were in the poor outcome group. In terms of mortality, inspiratory IJV diameter was 5.6 ± 2.9 mm in the survived group ( n = 76) and 7.6 ± 3.9 mm in the deceased group ( n = 17) ( P = 0.031). There was no difference between the venous compliance values and other diameter measurements of the patients. In the analysis performed with the subgroup with high N-terminal prohormone brain natriuretic peptide values, it was shown that both resting and inspiration diameter measurements were higher in the group with poor outcomes. Conclusion: There was no difference between the jugular vein compliance values in terms of mortality in patients admitted to the ED with COPD exacerbation. However, these measurements may have prognostic value in patients with COPD exacerbations complicated by heart failure.","PeriodicalId":45466,"journal":{"name":"Journal of Medical Ultrasound","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jmu.jmu_83_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background: Chronic obstructive pulmonary disease (COPD) exacerbations constitute a significant proportion of patients presenting to the emergency department (ED). It has been suggested that measurement of jugular venous diameter and compliance may have prognostic value in patients with heart failure. We hypothesized that these measurements may also be valuable in patients with advanced COPD. Methods: This study was a single-center, prospective, and cross-sectional study conducted in a university hospital between November 2020 and November 2021. In the study, internal jugular vein (IJV) diameters (inspiration, forced expiration, and rest) and jugular venous compliance were measured with ultrasound in patients who presented to the ED with COPD exacerbation. One month later, data about mortality, intensive care unit (ICU) admission, and any hospitalization were obtained and evaluated together with a range of laboratory parameters. Results: Data from a total of 93 patients were analyzed. Of these, 17 (18.2%) died, 19 (20.4%) were admitted to the ICU, and 36 (38.7%) were hospitalized at the end of the 1-month period. Consequently, a total of 44 patients (47.3%) were in the good outcome group and 49 patients (52.7%) were in the poor outcome group. In terms of mortality, inspiratory IJV diameter was 5.6 ± 2.9 mm in the survived group ( n = 76) and 7.6 ± 3.9 mm in the deceased group ( n = 17) ( P = 0.031). There was no difference between the venous compliance values and other diameter measurements of the patients. In the analysis performed with the subgroup with high N-terminal prohormone brain natriuretic peptide values, it was shown that both resting and inspiration diameter measurements were higher in the group with poor outcomes. Conclusion: There was no difference between the jugular vein compliance values in terms of mortality in patients admitted to the ED with COPD exacerbation. However, these measurements may have prognostic value in patients with COPD exacerbations complicated by heart failure.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
慢性阻塞性肺疾病加重患者颈静脉直径和顺应性的预后价值
背景:慢性阻塞性肺疾病(COPD)急性加重在急诊科(ED)就诊的患者中占很大比例。有人认为,测量颈静脉直径和依从性可能对心力衰竭患者的预后有价值。我们假设这些测量对晚期COPD患者也有价值。方法:本研究是一项单中心、前瞻性、横断面研究,于2020年11月至2021年11月在某大学医院进行。在这项研究中,用超声测量了伴有COPD加重的ED患者颈内静脉(IJV)直径(吸气、用力呼气和休息)和颈内静脉顺应性。一个月后,获得死亡率、重症监护病房(ICU)入院和任何住院情况的数据,并与一系列实验室参数一起进行评估。结果:共分析了93例患者的资料。其中死亡17例(18.2%),入住ICU 19例(20.4%),1个月结束时住院36例(38.7%)。结果,良结局组44例(47.3%),差结局组49例(52.7%)。在病死率方面,存活组为5.6±2.9 mm (n = 76),死亡组为7.6±3.9 mm (n = 17) (P = 0.031)。静脉顺应性值与患者的其他直径测量值之间没有差异。在对n端激素原脑利钠肽值高的亚组进行的分析中,结果表明,在预后较差的组中,静息和吸入直径测量值都较高。结论:在急诊科合并COPD加重患者中,颈静脉顺应性值与死亡率无显著差异。然而,这些测量可能对合并心力衰竭的COPD加重患者有预后价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Medical Ultrasound
Journal of Medical Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.30
自引率
9.10%
发文量
90
审稿时长
10 weeks
期刊介绍: The Journal of Medical Ultrasound is the peer-reviewed publication of the Asian Federation of Societies for Ultrasound in Medicine and Biology, and the Chinese Taipei Society of Ultrasound in Medicine. Its aim is to promote clinical and scientific research in ultrasonography, and to serve as a channel of communication among sonologists, sonographers, and medical ultrasound physicians in the Asia-Pacific region and wider international community. The Journal invites original contributions relating to the clinical and laboratory investigations and applications of ultrasonography.
期刊最新文献
CME Test. Comparison between Handheld Echocardiography and Cardiac Magnetic Resonance for Stroke Volume and Left Ventricular Ejection Fraction Quantification. Dissimilar Planes and Approaches with Common Neural Targets - A Cadaveric Evaluation of Three Different Ultrasound-guided Fascial Plane Blocks for Lumbar Plexus Nerves. Early Prenatal Detection of Recessive Split-hand/Foot Malformation Caused by a Homozygous Variant of WNT10B. Health-care Professionals' Perspectives on Ultrasound Evaluation of Arteriovenous Hemodialysis Fistula: A Narrative Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1