Densitometric simultaneous assessment of teneligliptin hydrobromide and pioglitazone hydrochloride in combined tablet

IF 1.3 Q4 CHEMISTRY, ANALYTICAL SEPARATION SCIENCE PLUS Pub Date : 2023-11-09 DOI:10.1002/sscp.202300139
Ashim Kumar Sen, Neel Bhimani, Dhanya B. Sen, Rajesh A. Maheshwari, Dipti Gohil, Shaileshkumar K. Koradia
{"title":"Densitometric simultaneous assessment of teneligliptin hydrobromide and pioglitazone hydrochloride in combined tablet","authors":"Ashim Kumar Sen, Neel Bhimani, Dhanya B. Sen, Rajesh A. Maheshwari, Dipti Gohil, Shaileshkumar K. Koradia","doi":"10.1002/sscp.202300139","DOIUrl":null,"url":null,"abstract":"Abstract A highly effective high‐performance thin‐layer chromatographic methodology has been developed and validated for the concurrent measurement of teneligliptin hydrobromide hydrate and pioglitazone hydrochloride in tablet offering excellent sensitivity, precision, accuracy, and robustness. The methodology involved using aluminum plates layered with silica gel 60F 254 were used, and the solvent system consisted of a mixture of chloroform, methanol, and ammonia (8:1:0.5 v/v/v). The analysis involved scanning of the plate at a wavelength of 229 nm and analyzing the resulting densitograms. The linear correlation was established over a range of concentrations 250–3000 ng/band for teneligliptin hydrobromide hydrate and 187.5–2250 ng/band for pioglitazone hydrochloride. The method displayed detection limits of 21.29 ng/band for teneligliptin hydrobromide hydrate and 25.97 ng/band for pioglitazone hydrochloride. The quantification limits were 64.52 ng/band for teneligliptin hydrobromide hydrate and 78.71 ng/band for pioglitazone hydrochloride. The results of precision parameters showed that the % relative standard deviation of peak area was consistently below 2%, indicating high precision. The accuracy of the method was demonstrated to be between 96% and 103%. Proposed method was found to be superior and capable of overcoming the shortcomings of previously reported methods for the assessment of both the drugs.","PeriodicalId":21639,"journal":{"name":"SEPARATION SCIENCE PLUS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEPARATION SCIENCE PLUS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/sscp.202300139","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract A highly effective high‐performance thin‐layer chromatographic methodology has been developed and validated for the concurrent measurement of teneligliptin hydrobromide hydrate and pioglitazone hydrochloride in tablet offering excellent sensitivity, precision, accuracy, and robustness. The methodology involved using aluminum plates layered with silica gel 60F 254 were used, and the solvent system consisted of a mixture of chloroform, methanol, and ammonia (8:1:0.5 v/v/v). The analysis involved scanning of the plate at a wavelength of 229 nm and analyzing the resulting densitograms. The linear correlation was established over a range of concentrations 250–3000 ng/band for teneligliptin hydrobromide hydrate and 187.5–2250 ng/band for pioglitazone hydrochloride. The method displayed detection limits of 21.29 ng/band for teneligliptin hydrobromide hydrate and 25.97 ng/band for pioglitazone hydrochloride. The quantification limits were 64.52 ng/band for teneligliptin hydrobromide hydrate and 78.71 ng/band for pioglitazone hydrochloride. The results of precision parameters showed that the % relative standard deviation of peak area was consistently below 2%, indicating high precision. The accuracy of the method was demonstrated to be between 96% and 103%. Proposed method was found to be superior and capable of overcoming the shortcomings of previously reported methods for the assessment of both the drugs.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
盐酸替尼格列汀与盐酸吡格列酮联用片的密度测定
建立了一种高效薄层色谱方法,用于同时测定水合替尼格列汀和盐酸吡格列酮片剂的含量,具有良好的灵敏度、精密度、准确度和鲁棒性。方法采用铝板层合硅胶60f254,溶剂体系由氯仿、甲醇和氨(8:1:0.5 v/v/v)的混合物组成。分析包括在2229nm波长处扫描平板,并分析所得的密度图。水合替尼格列汀在250 ~ 3000 ng/频带范围内与盐酸吡格列酮在187.5 ~ 2250 ng/频带范围内呈线性相关。方法的检出限分别为21.29 ng/带和25.97 ng/带。水合替尼格列汀的定量限为64.52 ng/带,盐酸吡格列酮的定量限为78.71 ng/带。精密度参数结果表明,峰面积的相对标准偏差始终在2%以下,精密度较高。结果表明,该方法的准确度在96% ~ 103%之间。所提出的方法被认为是优越的,并且能够克服以前报道的评估这两种药物的方法的缺点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
SEPARATION SCIENCE PLUS
SEPARATION SCIENCE PLUS CHEMISTRY, ANALYTICAL-
CiteScore
1.90
自引率
9.10%
发文量
111
期刊最新文献
Removal of Residual DNA and Host Cell Proteins for the Purification of Recombinant Staphylokinase Expressed in Escherichia coli Green Analytical Approach for HPLC Method Development for Quantification of Sorafenib and Its Pharmacopeia Impurities: LC–MS/MS Characterization and Toxicity Prediction of Stress Degradation Products A Cartridge Structure Facilitates Clinical Mass Spectrometry Pretreatment and Can be Integrated Into a High‐Throughput Instrument Comparison of Polysaccharide Profiles of Different Seaweeds Based on Ion Chromatography and Ultrahigh‐Performance Liquid Chromatography Quantification of Recycled Polypropylene Stabilizers for Quality Control by Liquid Chromatography–Tandem Mass Spectrometry Using Simple, Fast and Efficient Ultrasonic Extraction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1