Reduksi Harmonisa Pada Saluran Distribusi Tenaga Listrik Dengan Filter Daya Aktif

Elektron Pub Date : 2023-08-14 DOI:10.30630/eji.15.1.350
Fitriadi ., M. Imran Hamid, Herisanjani Herisanjani, Firmansyah Firmansyah, Zulka Hendri
{"title":"Reduksi Harmonisa Pada Saluran Distribusi Tenaga Listrik Dengan Filter Daya Aktif","authors":"Fitriadi ., M. Imran Hamid, Herisanjani Herisanjani, Firmansyah Firmansyah, Zulka Hendri","doi":"10.30630/eji.15.1.350","DOIUrl":null,"url":null,"abstract":"The large use of power converters in distribution lines causes poor power quality such as high produces harmonics in an electric power system that arises due to the operation of non-linear electrical equipment. The presence of harmonics in the power system distribution results in a very large loss in the system. In this paper had been done a simulation of power quality improvement through harmonic reduction using parallel active power filter. Active power filters work with control techniques based on the concept of instantaneous power to determine the amount of compensation currents that must be generated by the power compensator power circuit. The compensating current references generated by the control circuit are used by the hysteresis type controller to provide harmonic compensation arising. From the result of simulation using Simulink MATLAB, the harmonic value (THD) decrease caused by the 3 phase rectifier load on a distribution network which is used as case example. The harmonic value before compensated on the network is 27.85% at each phase, while after computing the harmonic value of the network decreases to 1,43% in R phase, 1,49% in S phase, and 1,34% in T phase.
","PeriodicalId":34872,"journal":{"name":"Elektron","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Elektron","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30630/eji.15.1.350","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The large use of power converters in distribution lines causes poor power quality such as high produces harmonics in an electric power system that arises due to the operation of non-linear electrical equipment. The presence of harmonics in the power system distribution results in a very large loss in the system. In this paper had been done a simulation of power quality improvement through harmonic reduction using parallel active power filter. Active power filters work with control techniques based on the concept of instantaneous power to determine the amount of compensation currents that must be generated by the power compensator power circuit. The compensating current references generated by the control circuit are used by the hysteresis type controller to provide harmonic compensation arising. From the result of simulation using Simulink MATLAB, the harmonic value (THD) decrease caused by the 3 phase rectifier load on a distribution network which is used as case example. The harmonic value before compensated on the network is 27.85% at each phase, while after computing the harmonic value of the network decreases to 1,43% in R phase, 1,49% in S phase, and 1,34% in T phase.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
谐波传导与活动过滤器的电源传导
在配电线路中大量使用电源变换器,导致电力系统中由于非线性电气设备的运行而产生的高谐波等电能质量差。电力系统配电系统中谐波的存在会给系统造成很大的损耗。本文对采用并联有源电力滤波器降谐波改善电能质量进行了仿真研究。有源功率滤波器与基于瞬时功率概念的控制技术一起工作,以确定功率补偿器功率电路必须产生的补偿电流的量。由控制电路产生的补偿电流参考被迟滞型控制器用来提供谐波补偿。从Simulink MATLAB仿真结果看,配电网中三相整流负荷对谐波值(THD)的降低,并以实例加以说明。各相位补偿前网络谐波值为27.85%,计算后网络谐波值分别为R相1.43%、S相1.49%、T相1.34%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
2
审稿时长
12 weeks
期刊最新文献
Análisis de la reflexión de ondas electromagnéticas a través de placas paralelas isótropas Ecosistema de Interoperabilidad basado en C++/MicroPython sobre plataformas Raspberry y ESP32 Estudio y desarrollo de un sistema para tomografía ultrasónica bidimensional Differential-drive Mobile Robot Controller with ROS 2 Support Impedancímetro en la banda de UHF mediante técnicas de reflectometría
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1