Evaluation of efficacy and identification of predictors of recurrence in patients after pulmonary vein cryoballoon ablation

Q4 Medicine Vestnik aritmologii Pub Date : 2023-10-06 DOI:10.35336/va-1195
G. A. Avanesyan, A. G. Filatov
{"title":"Evaluation of efficacy and identification of predictors of recurrence in patients after pulmonary vein cryoballoon ablation","authors":"G. A. Avanesyan, A. G. Filatov","doi":"10.35336/va-1195","DOIUrl":null,"url":null,"abstract":"Aim. To evaluate the effectiveness and identify predictors of recurrence after pulmonary veins (PV) cryoballoon isolation patients with atrial fibrillation (AF). Methods. In total, the study included 100 patients who met the selection criteria. Depending on the form and duration of AF paroxysms documented by ECG and Holter monitoring, patients were divided into two groups. The first group included 57 patients with paroxysmal AF (57%), and the second group included 43 patients with persistent AF (43%). Results. As a result of our study, important achievements of the greatest efficiency during cryoballon ablation were identified: isolation of all PV; achievement of the “input-output” block (elimination of spike activity according to the diagnostic electrode in the PV during appplication), which was recorded at a temperature of -30 and more °C; the minimum appplication time is 180 sec after reaching the entry-exit block. An electroanatomical diagram of the left atrium with a high frequency of left atrium and PV activity in patients with paroxysmal and persistent forms of AF was developed. Nine zones with pronounced activity were identified, more pronounced zones with low-amplitude activity in patients with persistent AF. The multivariate Cox analysis showed predictors, an exceptional effect on the risk of AF recurrence after cryoballoon ablation: the presence of diabetes mellitus led to the risk of AF recurrence by 2.39, incomplete isolation of the PV by 3.98 times, the value of left atrial volume index ≥ 61.9 ml/m 2 in 2.91 times, peak atrial longitudinal strain value of left atrium ≤29.3. Conclusion. The results of the study allow us to determine the criteria for high efficiency during cryoballoon ablation, as well as a high-risk group for relapse. When selecting patients for cryoballoon control of PV coronavirus, with the achievement of a greater one, possible factors should be considered: indexed volume of left atrium according to multispiral computed tomography, peak atrial longitudinal strain value of left atrium, absence of diabetes mellitus.","PeriodicalId":52704,"journal":{"name":"Vestnik aritmologii","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik aritmologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35336/va-1195","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Aim. To evaluate the effectiveness and identify predictors of recurrence after pulmonary veins (PV) cryoballoon isolation patients with atrial fibrillation (AF). Methods. In total, the study included 100 patients who met the selection criteria. Depending on the form and duration of AF paroxysms documented by ECG and Holter monitoring, patients were divided into two groups. The first group included 57 patients with paroxysmal AF (57%), and the second group included 43 patients with persistent AF (43%). Results. As a result of our study, important achievements of the greatest efficiency during cryoballon ablation were identified: isolation of all PV; achievement of the “input-output” block (elimination of spike activity according to the diagnostic electrode in the PV during appplication), which was recorded at a temperature of -30 and more °C; the minimum appplication time is 180 sec after reaching the entry-exit block. An electroanatomical diagram of the left atrium with a high frequency of left atrium and PV activity in patients with paroxysmal and persistent forms of AF was developed. Nine zones with pronounced activity were identified, more pronounced zones with low-amplitude activity in patients with persistent AF. The multivariate Cox analysis showed predictors, an exceptional effect on the risk of AF recurrence after cryoballoon ablation: the presence of diabetes mellitus led to the risk of AF recurrence by 2.39, incomplete isolation of the PV by 3.98 times, the value of left atrial volume index ≥ 61.9 ml/m 2 in 2.91 times, peak atrial longitudinal strain value of left atrium ≤29.3. Conclusion. The results of the study allow us to determine the criteria for high efficiency during cryoballoon ablation, as well as a high-risk group for relapse. When selecting patients for cryoballoon control of PV coronavirus, with the achievement of a greater one, possible factors should be considered: indexed volume of left atrium according to multispiral computed tomography, peak atrial longitudinal strain value of left atrium, absence of diabetes mellitus.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肺静脉冷冻球囊消融后疗效评价及复发预测因素的确定
的目标。目的:探讨房颤(AF)患者肺静脉(PV)冷冻球囊隔离术后复发的预测因素。方法。该研究总共纳入了100名符合选择标准的患者。根据心电图和动态心电图监测记录的房颤发作形式和持续时间,将患者分为两组。第一组包括57例阵发性房颤患者(57%),第二组包括43例持续性房颤患者(43%)。结果。通过我们的研究,确定了低温球囊消融过程中效率最高的重要成就:分离所有PV;实现“输入-输出”块(根据PV中的诊断电极在应用过程中消除尖峰活性),在-30℃或更高℃的温度下记录;到达出入口后,最少申请时间为180秒。在阵发性和持续性房颤患者中,左心房电解剖图显示左心房和PV活动频率高。我们确定了9个明显活动的区域,在持续性房颤患者中,更明显的是低幅度活动的区域。多因素Cox分析显示了预测因素,对冷冻球囊消融后房颤复发的风险有特殊影响:糖尿病导致AF复发的风险为2.39次,PV不完全分离的风险为3.98次,左心房容积指数≥61.9 ml/ m2的风险为2.91次,左心房纵应变峰值≤29.3次。结论。该研究的结果使我们能够确定低温球囊消融过程中高效的标准,以及复发的高危人群。在选择冠状病毒冷冻球囊控制患者时,如果成功率较高,应考虑以下因素:多螺旋ct示左心房指标容积、左心房纵应变峰值、有无糖尿病。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Vestnik aritmologii
Vestnik aritmologii Medicine-Pharmacology (medical)
CiteScore
0.50
自引率
0.00%
发文量
27
审稿时长
12 weeks
期刊最新文献
Number of ventricular premature beats and other causes of cardiomyopathy associated with arrhythmia: case series Left ventricle mechanical dispersion is a new universal marker of malignant ventricular tachyarrhythmias in patients with structural heart disease Laparoscopic approach for renal denervation: an experimental study on animals Remote magnetic-guided catheter ablation versus manual ablation in patients with repaired congenital heart disease and atrial tachyarrhythmias: propensity-matched observational study of long-term results Transcatheter occlusion of the coronary sinus increases radiofrequency ablation lesion size in the left ventricular myocardium: a new approach to improve the efficiency of ventricular tachyarrhythmia substrate destruction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1