Development and validation of high‐performance thin layer chromatographic method for concurrent estimation of dapagliflozin and vildagliptin in combined tablet
Ashim Kumar Sen, Satish B Khatariya, Dhanya B Sen, Rajesh A Maheshwari, Ashok H Akabari, Ramaswamy Velmurugan
{"title":"Development and validation of high‐performance thin layer chromatographic method for concurrent estimation of dapagliflozin and vildagliptin in combined tablet","authors":"Ashim Kumar Sen, Satish B Khatariya, Dhanya B Sen, Rajesh A Maheshwari, Ashok H Akabari, Ramaswamy Velmurugan","doi":"10.1002/sscp.202300132","DOIUrl":null,"url":null,"abstract":"Abstract Enhanced glycemic regulation in individuals with diabetes mellitus can be achieved using a fixed‐dose combination of dapagliflozin (10 mg) and vildagliptin (100 mg) in tablet. The primary objective of this research was to develop and validate a high‐performance thin layer chromatographic methodology for accurately measuring the quantities of dapagliflozin and vildagliptin in combined tablet formulation. The methodology involved using aluminum plates layered with silica gel 60F 254 , and the solvent system comprised of acetonitrile, benzene, and glacial acetic acid (9:1:2 v/v/v). Densitograms were scanned at a wavelength of 210 nm. The linearity of the procedure was established in the series of 200–2500 ng/band for dapagliflozin and 2000–25000 ng/band for vildagliptin, with correlation coefficients ( r 2 ) of 0.9931 and 0.9954, correspondingly. The method demonstrated good sensitivity, with detection limits of 21.07 ng/band for dapagliflozin and 154.97 ng/band for vildagliptin; quantification limits of 63.84 ng/band for dapagliflozin and 469.60 ng/band for vildagliptin. The methodology was found to be precise (% relative standard deviation of peak area <2) and accurate (recovery between 97% and 103%). Proposed method was found to be superior and capable of overcoming the shortcomings of previously reported methods for the assessment of dapagliflozin and vildagliptin in combined formulation.","PeriodicalId":21639,"journal":{"name":"SEPARATION SCIENCE PLUS","volume":"200 2","pages":"0"},"PeriodicalIF":1.3000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEPARATION SCIENCE PLUS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/sscp.202300132","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract Enhanced glycemic regulation in individuals with diabetes mellitus can be achieved using a fixed‐dose combination of dapagliflozin (10 mg) and vildagliptin (100 mg) in tablet. The primary objective of this research was to develop and validate a high‐performance thin layer chromatographic methodology for accurately measuring the quantities of dapagliflozin and vildagliptin in combined tablet formulation. The methodology involved using aluminum plates layered with silica gel 60F 254 , and the solvent system comprised of acetonitrile, benzene, and glacial acetic acid (9:1:2 v/v/v). Densitograms were scanned at a wavelength of 210 nm. The linearity of the procedure was established in the series of 200–2500 ng/band for dapagliflozin and 2000–25000 ng/band for vildagliptin, with correlation coefficients ( r 2 ) of 0.9931 and 0.9954, correspondingly. The method demonstrated good sensitivity, with detection limits of 21.07 ng/band for dapagliflozin and 154.97 ng/band for vildagliptin; quantification limits of 63.84 ng/band for dapagliflozin and 469.60 ng/band for vildagliptin. The methodology was found to be precise (% relative standard deviation of peak area <2) and accurate (recovery between 97% and 103%). Proposed method was found to be superior and capable of overcoming the shortcomings of previously reported methods for the assessment of dapagliflozin and vildagliptin in combined formulation.