{"title":"Development of quality criteria for long-term testing of intracortical electrodes","authors":"Charlotte Sielaff, Ute Urban, Ulrich P. Froriep","doi":"10.1515/cdbme-2023-1105","DOIUrl":null,"url":null,"abstract":"Abstract The use of intracortical electrodes is a crucial method for medical diagnosis and treatment and holds the promise for overcoming various neural diseases and challenges in prosthetics. The general physical and electrical function as well as the biocompatibility is extensively tested before intracortical electrodes are implanted, however, their longterm performance, is still limited through tissue scarring and electrode deterioration, and consequently a decrease in signal quality. To overcome this challenge, aspects such as materials selection, coatings, flexibility, and surgical procedures are often addressed. To date, however, a systematic, industry - compatible process for long-term functional testing of new intracortical electrodes technologies is still lacking. Implementation of a general overall in vivo testing procedure with defined quality criteria would enable reliable in vivo longterm (> 30 days) device assessment. This could reduce the risk in developing probes for long-term performance and pave the way for clinical application in patients suffering from neural diseases.","PeriodicalId":10739,"journal":{"name":"Current Directions in Biomedical Engineering","volume":"326 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Directions in Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cdbme-2023-1105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract The use of intracortical electrodes is a crucial method for medical diagnosis and treatment and holds the promise for overcoming various neural diseases and challenges in prosthetics. The general physical and electrical function as well as the biocompatibility is extensively tested before intracortical electrodes are implanted, however, their longterm performance, is still limited through tissue scarring and electrode deterioration, and consequently a decrease in signal quality. To overcome this challenge, aspects such as materials selection, coatings, flexibility, and surgical procedures are often addressed. To date, however, a systematic, industry - compatible process for long-term functional testing of new intracortical electrodes technologies is still lacking. Implementation of a general overall in vivo testing procedure with defined quality criteria would enable reliable in vivo longterm (> 30 days) device assessment. This could reduce the risk in developing probes for long-term performance and pave the way for clinical application in patients suffering from neural diseases.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
皮质内电极长期试验质量标准的制定
皮质内电极的使用是医学诊断和治疗的重要方法,有望克服各种神经疾病和假肢的挑战。在植入皮质内电极之前,对其一般的物理和电功能以及生物相容性进行了广泛的测试,然而,由于组织瘢痕和电极退化,它们的长期性能仍然受到限制,从而导致信号质量下降。为了克服这一挑战,材料选择、涂层、灵活性和手术程序等方面经常得到解决。然而,到目前为止,对于新的皮质内电极技术的长期功能测试,仍然缺乏一个系统的、工业兼容的过程。实施具有明确质量标准的一般总体体内检测程序将实现可靠的体内长期(>30天)器械评估。这可以降低开发具有长期性能的探针的风险,并为神经疾病患者的临床应用铺平道路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Current Directions in Biomedical Engineering
Current Directions in Biomedical Engineering Engineering-Biomedical Engineering
CiteScore
0.90
自引率
0.00%
发文量
239
审稿时长
14 weeks
期刊最新文献
Stability of cell adhesion noise analysis for the detection of cancer cell lines Consideration of Kv ion channels as firstorder systems Photovoltaic Stimulation Induces Overdrive Suppression in Embryonic Chicken Cardiomyocytes Comparative Analysis of Mechanical Water Level Tank and Human Fluid Flow ECG Beat classification: Impact of linear dependent samples
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1