Manufacture and extraction of PLLA films with incorporated metal ions

Thomas Eickner, Sabine Illner, Niels Grabow, Olga Hahn, Kirsten Peters, Brigitte Müller-Hilke, Anika Jonitz-Heincke, Rainer Bader, Tomas Fiedler
{"title":"Manufacture and extraction of PLLA films with incorporated metal ions","authors":"Thomas Eickner, Sabine Illner, Niels Grabow, Olga Hahn, Kirsten Peters, Brigitte Müller-Hilke, Anika Jonitz-Heincke, Rainer Bader, Tomas Fiedler","doi":"10.1515/cdbme-2023-1113","DOIUrl":null,"url":null,"abstract":"Abstract For the in vitro examination of the effects on cells and tissues of metal ions derived from implants by wear and corrosion, a system is needed to release metal ions in a controlled and sustained manner. As small concentrations may have an impact on biological systems, a corresponding slow release over a defined period of time is necessary. Here, a manufacturing method of polymeric Poly(L-lactic acid) (PLLA) films with incorporated cobalt ions via dip coating is reported. The establishment of two analytical methods for the detection and quantification of cobalt ions is shown. High performance liquid chromatography enables cobalt quantification over a concentration range of 0.33 μg/mL up to 33 μg/mL in sample solutions. Extraction and detection of cobalt ions from solvent cast PLLA-cobalt-films shows the feasibility of the manufacturing method. Initial biocompatibility tests with manufactured PLLA-cobaltfilms showed no effects on adipose derived primary mesenchymal stem cells (adMSCs).","PeriodicalId":10739,"journal":{"name":"Current Directions in Biomedical Engineering","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Directions in Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cdbme-2023-1113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract For the in vitro examination of the effects on cells and tissues of metal ions derived from implants by wear and corrosion, a system is needed to release metal ions in a controlled and sustained manner. As small concentrations may have an impact on biological systems, a corresponding slow release over a defined period of time is necessary. Here, a manufacturing method of polymeric Poly(L-lactic acid) (PLLA) films with incorporated cobalt ions via dip coating is reported. The establishment of two analytical methods for the detection and quantification of cobalt ions is shown. High performance liquid chromatography enables cobalt quantification over a concentration range of 0.33 μg/mL up to 33 μg/mL in sample solutions. Extraction and detection of cobalt ions from solvent cast PLLA-cobalt-films shows the feasibility of the manufacturing method. Initial biocompatibility tests with manufactured PLLA-cobaltfilms showed no effects on adipose derived primary mesenchymal stem cells (adMSCs).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
含金属离子PLLA薄膜的制备与提取
为了在体外检测植入物产生的金属离子对细胞和组织的磨损和腐蚀的影响,需要一个系统以可控和持续的方式释放金属离子。由于小浓度可能对生物系统产生影响,因此在规定的时间内进行相应的缓慢释放是必要的。本文报道了一种采用浸涂法制备钴离子掺杂聚乳酸(PLLA)薄膜的方法。建立了两种检测和定量钴离子的分析方法。高效液相色谱法可在样品溶液中0.33 μg/mL至33 μg/mL的浓度范围内对钴进行定量。溶剂铸造pla -钴膜中钴离子的提取和检测表明了该制备方法的可行性。用人造pla -钴膜进行的初步生物相容性测试显示,对脂肪来源的原代间充质干细胞(adMSCs)没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Current Directions in Biomedical Engineering
Current Directions in Biomedical Engineering Engineering-Biomedical Engineering
CiteScore
0.90
自引率
0.00%
发文量
239
审稿时长
14 weeks
期刊最新文献
Stability of cell adhesion noise analysis for the detection of cancer cell lines Consideration of Kv ion channels as firstorder systems Photovoltaic Stimulation Induces Overdrive Suppression in Embryonic Chicken Cardiomyocytes Comparative Analysis of Mechanical Water Level Tank and Human Fluid Flow ECG Beat classification: Impact of linear dependent samples
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1