{"title":"Effect of pulsed current cathodic protection on pipeline steel API 5L X65 corrosion mitigation: An investigation and machine learning-assisted modeling","authors":"Hosein Eslamian ,&nbsp;Mehdi Javidi ,&nbsp;Mohammad Reza Zamani ,&nbsp;Mohammad Mahdi Dana ,&nbsp;Eghbal Mansoori","doi":"10.1016/j.corcom.2023.01.005","DOIUrl":null,"url":null,"abstract":"<div><p>Pulsed current cathodic protection (PCCP) could be more effective than direct current cathodic protection (DCCP) for mitigating corrosion in buried structures in the oil and gas industries if appropriate pulsed parameters are chosen. The purpose of this research is to present the corrosion prevention mechanism of the PCCP technique by taking into account the effects of duty cycle as well as frequency, modeling the relationships between pulse parameters (frequency and duty cycle) and system outputs (corrosion rate, protective current and pipe-to-soil potential) and finally identifying the most effective protection conditions over a wide range of frequency (2–10 kHz) and duty cycle (25%-75%). For this, pipe-to-soil potential, pH, current and power consumption, corrosion rate, surface deposits and investigation of pitting corrosion were taken into account. To model the input-output relationship in the PCCP method, a data-driven machine learning approach was used by training an artificial neural network (ANN). The results revealed that the PCCP system could yield the best protection conditions at 10 kHz frequency and 50% duty cycle, resulting in the longest protection length with the lowest corrosion rate at a consumption current 0.3 time that of the DCCP method. In the frequency range of 6–10 kHz and duty cycles of 50%-75%, SEM images indicated a uniform distribution of calcite deposits and no pits on cathode surface.</p></div>","PeriodicalId":100337,"journal":{"name":"Corrosion Communications","volume":"12 ","pages":"Pages 29-45"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2667266923000415/pdfft?md5=febfcceb33463f084b57cd1f7f6ce00b&pid=1-s2.0-S2667266923000415-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Corrosion Communications","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667266923000415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Pulsed current cathodic protection (PCCP) could be more effective than direct current cathodic protection (DCCP) for mitigating corrosion in buried structures in the oil and gas industries if appropriate pulsed parameters are chosen. The purpose of this research is to present the corrosion prevention mechanism of the PCCP technique by taking into account the effects of duty cycle as well as frequency, modeling the relationships between pulse parameters (frequency and duty cycle) and system outputs (corrosion rate, protective current and pipe-to-soil potential) and finally identifying the most effective protection conditions over a wide range of frequency (2–10 kHz) and duty cycle (25%-75%). For this, pipe-to-soil potential, pH, current and power consumption, corrosion rate, surface deposits and investigation of pitting corrosion were taken into account. To model the input-output relationship in the PCCP method, a data-driven machine learning approach was used by training an artificial neural network (ANN). The results revealed that the PCCP system could yield the best protection conditions at 10 kHz frequency and 50% duty cycle, resulting in the longest protection length with the lowest corrosion rate at a consumption current 0.3 time that of the DCCP method. In the frequency range of 6–10 kHz and duty cycles of 50%-75%, SEM images indicated a uniform distribution of calcite deposits and no pits on cathode surface.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
脉冲电流阴极保护对管道钢API 5L X65缓蚀的影响:一项调查和机器学习辅助建模
如果选择合适的脉冲参数,脉冲电流阴极保护(PCCP)可以比直流阴极保护(DCCP)更有效地减轻石油和天然气工业中埋地结构的腐蚀。本研究的目的是通过考虑占空比和频率的影响,对脉冲参数(频率和占空比)和系统输出(腐蚀速率、保护电流和管土电位)之间的关系进行建模,并最终确定在宽频率(2-10 kHz)和占空比(25%-75%)范围内最有效的保护条件,来展示PCCP技术的防腐机制。为此,考虑了管道-土壤电位、pH值、电流和功率消耗、腐蚀速率、表面沉积物和点蚀调查。为了对PCCP方法中的输入-输出关系建模,采用数据驱动的机器学习方法训练人工神经网络(ANN)。结果表明,PCCP系统在10 kHz频率和50%占空比下的保护条件最好,在消耗电流为DCCP方法0.3倍的情况下,保护时间最长,腐蚀速率最低。在频率为6 ~ 10 kHz,占空比为50% ~ 75%的范围内,阴极表面方解石沉积分布均匀,无凹坑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.30
自引率
0.00%
发文量
0
期刊最新文献
Unraveling the local stress corrosion cracking behavior of Alloy 690 plug in a high-temperature concentrated alkaline solution Effects of pre-strain on hydrogen-induced stress corrosion cracking behavior of Q345R steel in hydrofluoric acid vapor environment Synergistic effects of CO2 and H2S on stress corrosion cracking of stainless steel 254SMo in extremely aggressive oilfield environment High temperature oxidation behavior of γʹ-strengthened CoNi-base superalloys Oxygen-driven de-alloying of Fe-14Cr-12Ni-10Mn-3Cu-2.5Al-1Nb austenitic steel at 500 °C in static Pb-Bi eutectic with concentration of dissolved oxygen alternating from ∼10-6 to 10-9 mass% for 10000 h
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1