Effect of Natural Ventilation on Thermal Performance of Different Residential Building Forms in the Hot-dry Climate of Jordan

IF 0.6 Q3 MULTIDISCIPLINARY SCIENCES Pertanika Journal of Science and Technology Pub Date : 2023-11-06 DOI:10.47836/pjst.32.1.03
Esraa Shehadeh Abbaas, Mazran Ismail, Ala’eddin Ahmad Saif, Muhamad Azhar Ghazali
{"title":"Effect of Natural Ventilation on Thermal Performance of Different Residential Building Forms in the Hot-dry Climate of Jordan","authors":"Esraa Shehadeh Abbaas, Mazran Ismail, Ala’eddin Ahmad Saif, Muhamad Azhar Ghazali","doi":"10.47836/pjst.32.1.03","DOIUrl":null,"url":null,"abstract":"This work presents a simulation study on the impact of natural ventilation on the thermal performance and thermal comfort of residential buildings of different forms in the hot-dry climate of Amman, the capital of Jordan. Three existing triple-storey residential buildings with different forms, i.e., rectangular, L-shape, and U-shape, are taken as case studies. Models with similar construction and dimensions of the buildings under investigation are designed using the OpenStudio plugin SketchUp software. Two rooms within these buildings have been considered for simulation with the aid of the EnergyPlus simulator for two cases: the basic case with no ventilation and the case with ventilation. The thermal parameters, including the air temperature, relative humidity, air speed, and mean radiant temperature of both rooms, have been extracted from the simulation. The thermal performance of these buildings is analyzed based on the indoor air temperature and mean radiant temperature, while the thermal performance is investigated via the ASHRAE-55 adaptive model. The results show that the rectangular-shaped building has the best thermal performance in unventilated conditions for the middle room on the middle floor (Room 1). In contrast, the U-shape shows better results for the west-northern room on the same floor (Room 2). On the other hand, introducing natural ventilation to the buildings reduces the indoor temperature and, subsequently, enhances the thermal performance where the buildings transform to be within the comfort zone most of the time, according to the ASHRAE-55 adaptive model. Generally, rectangular and U-shaped buildings show comparable thermal performance, while L-shaped buildings have relatively the worst performance.","PeriodicalId":46234,"journal":{"name":"Pertanika Journal of Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2023-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pertanika Journal of Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47836/pjst.32.1.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

This work presents a simulation study on the impact of natural ventilation on the thermal performance and thermal comfort of residential buildings of different forms in the hot-dry climate of Amman, the capital of Jordan. Three existing triple-storey residential buildings with different forms, i.e., rectangular, L-shape, and U-shape, are taken as case studies. Models with similar construction and dimensions of the buildings under investigation are designed using the OpenStudio plugin SketchUp software. Two rooms within these buildings have been considered for simulation with the aid of the EnergyPlus simulator for two cases: the basic case with no ventilation and the case with ventilation. The thermal parameters, including the air temperature, relative humidity, air speed, and mean radiant temperature of both rooms, have been extracted from the simulation. The thermal performance of these buildings is analyzed based on the indoor air temperature and mean radiant temperature, while the thermal performance is investigated via the ASHRAE-55 adaptive model. The results show that the rectangular-shaped building has the best thermal performance in unventilated conditions for the middle room on the middle floor (Room 1). In contrast, the U-shape shows better results for the west-northern room on the same floor (Room 2). On the other hand, introducing natural ventilation to the buildings reduces the indoor temperature and, subsequently, enhances the thermal performance where the buildings transform to be within the comfort zone most of the time, according to the ASHRAE-55 adaptive model. Generally, rectangular and U-shaped buildings show comparable thermal performance, while L-shaped buildings have relatively the worst performance.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
约旦干热气候下自然通风对不同居住建筑热工性能的影响
本文模拟研究了约旦首都安曼干热气候条件下自然通风对不同形式住宅热工性能和热舒适的影响。以现有的三层住宅为例,分别为矩形、l形和u形三种不同的形式。使用OpenStudio插件SketchUp软件设计与被调查建筑相似的结构和尺寸的模型。这些建筑中的两个房间已经考虑在EnergyPlus模拟器的帮助下进行两种情况的模拟:没有通风的基本情况和有通风的情况。从模拟中提取了两个房间的热参数,包括空气温度、相对湿度、风速和平均辐射温度。采用ASHRAE-55自适应模型对建筑的热工性能进行研究,并根据室内空气温度和平均辐射温度对建筑的热工性能进行分析。结果表明,在不通风条件下,矩形建筑的中间楼层房间(1号房间)的热学性能最好。相反,u型建筑在同一楼层的西-北房间(2号房间)的热学性能更好。另一方面,为建筑引入自然通风降低了室内温度,从而提高了热学性能,使建筑在大多数时间内转变为舒适区。根据ASHRAE-55自适应模型。一般来说,矩形和u型建筑的热性能相当,而l型建筑的热性能相对较差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Pertanika Journal of Science and Technology
Pertanika Journal of Science and Technology MULTIDISCIPLINARY SCIENCES-
CiteScore
1.50
自引率
16.70%
发文量
178
期刊介绍: Pertanika Journal of Science and Technology aims to provide a forum for high quality research related to science and engineering research. Areas relevant to the scope of the journal include: bioinformatics, bioscience, biotechnology and bio-molecular sciences, chemistry, computer science, ecology, engineering, engineering design, environmental control and management, mathematics and statistics, medicine and health sciences, nanotechnology, physics, safety and emergency management, and related fields of study.
期刊最新文献
A Review on the Development of Microcarriers for Cell Culture Applications The Compatibility of Cement Bonded Fibreboard Through Dimensional Stability Analysis: A Review Bending Effects on Polyvinyl Alcohol Thin Film for Flexible Wearable Antenna Substrate Mesh Optimisation for General 3D Printed Objects with Cusp-Height Triangulation Approach The Riblet Short-Slot Coupler Using Substrate Integrated Waveguide (SIW) for High-frequency Applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1