Stroke Volume Variation is a Good Predictor of Fluid Responsiveness in Cardiac Surgery Patients with Implanted Intra-aortic Balloon Pump

IF 0.3 4区 综合性期刊 Q4 MULTIDISCIPLINARY SCIENCES Comptes Rendus De L Academie Bulgare Des Sciences Pub Date : 2023-04-30 DOI:10.7546/crabs.2023.04.14
Rostislav Enev, Fillip Abedinov, Neda Bakalova, Margarita Atanasova, Nezabravka Chilingirova, Plamen Krastev
{"title":"Stroke Volume Variation is a Good Predictor of Fluid Responsiveness in Cardiac Surgery Patients with Implanted Intra-aortic Balloon Pump","authors":"Rostislav Enev, Fillip Abedinov, Neda Bakalova, Margarita Atanasova, Nezabravka Chilingirova, Plamen Krastev","doi":"10.7546/crabs.2023.04.14","DOIUrl":null,"url":null,"abstract":"There is a vast body of evidence in favour of individualising fluid therapy using dynamic hemodynamic indices like stroke volume variation (SVV). Patients with implanted intra-aortic balloon pump (IABP) are excluded from this approach because of pulse contour artifacts caused by the pump. The aim of this work is to test whether SVV can be used for fluid responsiveness prediction in these patients. Patients after cardiac surgery with implanted IABP were included in this study. SVV was measured after placing the IABP on standby mode for one minute. Cardiac output (CO) measurement was obtained via Swan-Ganz catheter before and after a 6 ml/kg fluid challenge. Fluid responsiveness was defined as increase of CO by at least 10%. SVV above 8.5% showed a good correlation with fluid responsiveness. Sensitivity was 95 (95% CI 85 to 100) and specificity 82 (95% CI 72 to 92). SVV had an area under the ROC curve 0.91 (95% CI 0.81 to 1.0) SVV is a good predictor of fluid responsiveness in patients with IABP. SVV should not be excluded as a fluid therapy guide for these patients. Placing the pump on standby for one minute allows obtaining an accurate measurement of this important variable.","PeriodicalId":50652,"journal":{"name":"Comptes Rendus De L Academie Bulgare Des Sciences","volume":"122 1","pages":"0"},"PeriodicalIF":0.3000,"publicationDate":"2023-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Comptes Rendus De L Academie Bulgare Des Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7546/crabs.2023.04.14","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

There is a vast body of evidence in favour of individualising fluid therapy using dynamic hemodynamic indices like stroke volume variation (SVV). Patients with implanted intra-aortic balloon pump (IABP) are excluded from this approach because of pulse contour artifacts caused by the pump. The aim of this work is to test whether SVV can be used for fluid responsiveness prediction in these patients. Patients after cardiac surgery with implanted IABP were included in this study. SVV was measured after placing the IABP on standby mode for one minute. Cardiac output (CO) measurement was obtained via Swan-Ganz catheter before and after a 6 ml/kg fluid challenge. Fluid responsiveness was defined as increase of CO by at least 10%. SVV above 8.5% showed a good correlation with fluid responsiveness. Sensitivity was 95 (95% CI 85 to 100) and specificity 82 (95% CI 72 to 92). SVV had an area under the ROC curve 0.91 (95% CI 0.81 to 1.0) SVV is a good predictor of fluid responsiveness in patients with IABP. SVV should not be excluded as a fluid therapy guide for these patients. Placing the pump on standby for one minute allows obtaining an accurate measurement of this important variable.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
卒中容量变化是心脏手术患者植入主动脉内球囊泵后液体反应性的良好预测指标
有大量的证据支持使用动态血流动力学指标如脑卒中容积变化(SVV)进行个体化液体治疗。植入主动脉内球囊泵(IABP)的患者由于泵引起的脉冲轮廓伪影而被排除在该方法之外。这项工作的目的是测试SVV是否可以用于预测这些患者的液体反应性。本研究纳入了心脏手术后植入IABP的患者。将IABP置于待机模式一分钟后测量SVV。心输出量(CO)测量通过Swan-Ganz导管在6 ml/kg液体刺激前后。流体响应性定义为CO增加至少10%。SVV高于8.5%与流体反应性有良好的相关性。敏感性为95 (95% CI 85 ~ 100),特异性为82 (95% CI 72 ~ 92)。SVV的ROC曲线下面积为0.91 (95% CI 0.81 ~ 1.0) SVV是IABP患者液体反应性的良好预测因子。不应排除SVV作为这些患者的液体治疗指南。将泵置于待机状态一分钟,可以获得对这一重要变量的准确测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Comptes Rendus De L Academie Bulgare Des Sciences
Comptes Rendus De L Academie Bulgare Des Sciences 综合性期刊-综合性期刊
CiteScore
0.60
自引率
33.30%
发文量
181
审稿时长
3-6 weeks
期刊介绍: Founded in 1948 by academician Georgy Nadjakov, "Comptes rendus de l’Académie bulgare des Sciences" is also known as "Доклади на БАН","Доклады Болгарской академии наук" and "Proceeding of the Bulgarian Academy of Sciences". If applicable, the name of the journal should be abbreviated as follows: C. R. Acad. Bulg. Sci. (according to ISO)
期刊最新文献
A Three-link Gravity-balanced Mechanism for Operating Room Assistance A Study on Lacunary Strong Convergence according to Modulus Functions Two Innovations for Critical Infrastructure Protection from Natural Disasters Prenatal Progesterone Treatment Induces Sex-dependent Anxiety and Depressive-like Behaviour in Adult Offspring Design and Implementation of Modified Multilevel Inverter FED BLDC Motor for Electric Vehicle Application
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1