Comparison of marginal bone loss in SLA and RBM implants: A prospective cohort study

Majid Nemati, Bahar Dadkhah, Reza Tabrizi, Shervin Shafiei, Hamidreza Moslemi
{"title":"Comparison of marginal bone loss in SLA and RBM implants: A prospective cohort study","authors":"Majid Nemati, Bahar Dadkhah, Reza Tabrizi, Shervin Shafiei, Hamidreza Moslemi","doi":"10.4103/njms.njms_165_22","DOIUrl":null,"url":null,"abstract":"Context: The study aims to answer the following question: Among the patients who received a dental implant, is there any difference in marginal bone loss (MBL) between sandblasted and acid-etched (SLA) and resorbable blast media (RBM) implants? Aims: The study aimed to evaluate marginal bone loss in SLA and RBM implants one year after loading. Settings and Design: A Prospective Cohort Study. Methods and Material: In this prospective cohort study with a pre-protocol population, subjects were assigned into two groups: Subjects received SLA implants in group 1 and RBM in group 2. MBL was assessed 12 months after loadings through digital parallel radiographs. Statistical Analysis Used: An Independent t -test was used to compare MBL between the two groups. Results: Sixty-six implants were studied (each group 33 implants). The mean of MBL in the RBM group was significantly higher than the SLA group (1.39 ± 0.31 mm, 0.89 ± 0.26 mm, respectively, P < 0.001). MBL in the mesial sides of implants in the RBM group was significantly higher than the SLA group (1.28 ± 0.29 mm, 0.8 ± 0.29 mm, respectively, P < 0.001). Analysis of the data demonstrated a significantly higher mean of MBL in the distal sides of implants in the RBM group than in the SLA group (1.51 ± 0.35 mm, 0.97 ± 0.27 mm, respectively, P < 0.001). In both groups, the mean of MBL on the distal side was significantly higher than on the mesial side ( P < 0.05). Conclusions: Within this study's limitation, RBM implants showed significantly more MBL than SLA implants.","PeriodicalId":18827,"journal":{"name":"National Journal of Maxillofacial Surgery","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"National Journal of Maxillofacial Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/njms.njms_165_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Context: The study aims to answer the following question: Among the patients who received a dental implant, is there any difference in marginal bone loss (MBL) between sandblasted and acid-etched (SLA) and resorbable blast media (RBM) implants? Aims: The study aimed to evaluate marginal bone loss in SLA and RBM implants one year after loading. Settings and Design: A Prospective Cohort Study. Methods and Material: In this prospective cohort study with a pre-protocol population, subjects were assigned into two groups: Subjects received SLA implants in group 1 and RBM in group 2. MBL was assessed 12 months after loadings through digital parallel radiographs. Statistical Analysis Used: An Independent t -test was used to compare MBL between the two groups. Results: Sixty-six implants were studied (each group 33 implants). The mean of MBL in the RBM group was significantly higher than the SLA group (1.39 ± 0.31 mm, 0.89 ± 0.26 mm, respectively, P < 0.001). MBL in the mesial sides of implants in the RBM group was significantly higher than the SLA group (1.28 ± 0.29 mm, 0.8 ± 0.29 mm, respectively, P < 0.001). Analysis of the data demonstrated a significantly higher mean of MBL in the distal sides of implants in the RBM group than in the SLA group (1.51 ± 0.35 mm, 0.97 ± 0.27 mm, respectively, P < 0.001). In both groups, the mean of MBL on the distal side was significantly higher than on the mesial side ( P < 0.05). Conclusions: Within this study's limitation, RBM implants showed significantly more MBL than SLA implants.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SLA和RBM种植体边缘骨丢失的比较:一项前瞻性队列研究
背景:本研究旨在回答以下问题:在接受牙科种植体的患者中,喷砂和酸蚀(SLA)和可吸收爆破介质(RBM)种植体的边缘骨质流失(MBL)是否有差异?目的:本研究旨在评估SLA和RBM种植体在装填一年后的边缘骨流失情况。环境和设计:一项前瞻性队列研究。方法和材料:在这项有方案前人群的前瞻性队列研究中,受试者被分为两组:第一组接受SLA植入物,第二组接受RBM。加载后12个月通过数字平行x线片评估MBL。采用统计学分析:两组MBL比较采用独立t检验。结果:共研究种植体66颗(每组33颗)。RBM组MBL均值显著高于SLA组(分别为1.39±0.31 mm、0.89±0.26 mm), P <0.001)。RBM组种植体内侧MBL显著高于SLA组(分别为1.28±0.29 mm、0.8±0.29 mm);0.001)。数据分析显示,RBM组种植体远端MBL均值显著高于SLA组(分别为1.51±0.35 mm、0.97±0.27 mm, P <0.001)。在两组中,远端MBL的平均值显著高于中端(P <0.05)。结论:在本研究的局限性内,RBM种植体比SLA种植体显示出明显更多的MBL。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Soft skills for personal development of the surgeon for improved outcomes for patient and surgeon. Oral rhabdomyosarcoma of mandibular region: A case report. Evaluation of efficacy of simvastatin in bone regeneration following local application in third molar extraction socket: A randomized control trial. Comparative evaluation of implant stability and crestal bone level between tapered and cylindrical implants in the posterior regions of the mandible: A prospective, randomized, split-mouth clinical trial. Comparative and clinical evaluation between piezoelectric and conventional rotary techniques for mandibular impacted third molar extraction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1