{"title":"Exhaust flow calibration for a large-scale calorimetry system using tracer gas dilution","authors":"Rodney A. Bryant","doi":"10.1002/fam.3183","DOIUrl":null,"url":null,"abstract":"<p>Exhaust flow measurements are a significant source of uncertainty for measurements of heat release rate in large-scale fire experiments. Irregular flow distributions are often present in the exhaust ducts making it difficult to measure flow accurately. Tracer gas dilution (TGD), a measurement method for volume flow, is not sensitive to flow distribution and has been applied to calibrate flow measurement devices at the exhaust ducts of a large-scale open calorimetry system. The in-line calibration reduced the bias in the exhaust flow measurement by as much as 6% improving the overall measurement accuracy of the heat release rate. Experimental results provide evidence that the flow calibration is an improvement over the accepted practice of developing a flow correction from the comparison of oxygen consumption calorimetry with the heat output from a gas burner. The flow calibration is valid for a wide range of flow conditions and decouples the oxygen consumption calorimetry measurement from any error in determining the heat release rate from the gas burner.</p>","PeriodicalId":12186,"journal":{"name":"Fire and Materials","volume":"48 2","pages":"286-296"},"PeriodicalIF":2.0000,"publicationDate":"2023-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire and Materials","FirstCategoryId":"88","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/fam.3183","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Exhaust flow measurements are a significant source of uncertainty for measurements of heat release rate in large-scale fire experiments. Irregular flow distributions are often present in the exhaust ducts making it difficult to measure flow accurately. Tracer gas dilution (TGD), a measurement method for volume flow, is not sensitive to flow distribution and has been applied to calibrate flow measurement devices at the exhaust ducts of a large-scale open calorimetry system. The in-line calibration reduced the bias in the exhaust flow measurement by as much as 6% improving the overall measurement accuracy of the heat release rate. Experimental results provide evidence that the flow calibration is an improvement over the accepted practice of developing a flow correction from the comparison of oxygen consumption calorimetry with the heat output from a gas burner. The flow calibration is valid for a wide range of flow conditions and decouples the oxygen consumption calorimetry measurement from any error in determining the heat release rate from the gas burner.
期刊介绍:
Fire and Materials is an international journal for scientific and technological communications directed at the fire properties of materials and the products into which they are made. This covers all aspects of the polymer field and the end uses where polymers find application; the important developments in the fields of natural products - wood and cellulosics; non-polymeric materials - metals and ceramics; as well as the chemistry and industrial applications of fire retardant chemicals.
Contributions will be particularly welcomed on heat release; properties of combustion products - smoke opacity, toxicity and corrosivity; modelling and testing.