The Validity of a Novel Low-Cost, Wearable Physical Activity Monitor in a Laboratory Setting

Jacob Barkley, Andrew Newton, Ellen Glickman
{"title":"The Validity of a Novel Low-Cost, Wearable Physical Activity Monitor in a Laboratory Setting","authors":"Jacob Barkley, Andrew Newton, Ellen Glickman","doi":"10.53520/rdhs2023.10469","DOIUrl":null,"url":null,"abstract":"Introduction: Wearable physical activity monitors are popular and may provide a more accurate data than subjective methods. The present study assessed the validity of a novel, low-cost wearable physical activity monitor (Movband 3) relative to established measures. Methods: Participants (N = 19) completed four treadmill stages (1.5, 3.0, 4.0, 6.0 MPH) while wearing the Movband 3 and the validated Actigraph GT1M monitor. Oxygen consumption (VO2 ml/kg/min) and heart rate (beats/min) were recorded. The relationship between Movband data and established measures was assessed via Pearson’s correlations. Tests of agreement were performed for actual and Movband miles traveled. Results: There were large, positive, significant (p < 0.001) effect sizes for the associations between Movband counts and Actigraph counts (r = 0.72), VO2 (r = 0.59), and heart rate (r = 0.63). There was also a large, positive, significant (p < 0.001) association between actual and Movband miles (r = 0.97). However, the difference (Δ) between Movband and actual miles was greater than a null hypothesis of zero (∆ = 0.77 ± 0.45 miles or 31.8%, t = 7.4, p < 0.001). Conclusion: While there was evidence to support the validity of the Movband 3 for the assessment of physical activity intensity this device did not provide an accurate measure of miles traveled.","PeriodicalId":74674,"journal":{"name":"Research Directs in health sciences","volume":"210 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research Directs in health sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53520/rdhs2023.10469","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Wearable physical activity monitors are popular and may provide a more accurate data than subjective methods. The present study assessed the validity of a novel, low-cost wearable physical activity monitor (Movband 3) relative to established measures. Methods: Participants (N = 19) completed four treadmill stages (1.5, 3.0, 4.0, 6.0 MPH) while wearing the Movband 3 and the validated Actigraph GT1M monitor. Oxygen consumption (VO2 ml/kg/min) and heart rate (beats/min) were recorded. The relationship between Movband data and established measures was assessed via Pearson’s correlations. Tests of agreement were performed for actual and Movband miles traveled. Results: There were large, positive, significant (p < 0.001) effect sizes for the associations between Movband counts and Actigraph counts (r = 0.72), VO2 (r = 0.59), and heart rate (r = 0.63). There was also a large, positive, significant (p < 0.001) association between actual and Movband miles (r = 0.97). However, the difference (Δ) between Movband and actual miles was greater than a null hypothesis of zero (∆ = 0.77 ± 0.45 miles or 31.8%, t = 7.4, p < 0.001). Conclusion: While there was evidence to support the validity of the Movband 3 for the assessment of physical activity intensity this device did not provide an accurate measure of miles traveled.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种新型低成本、可穿戴式运动监测仪在实验室环境中的有效性
简介:可穿戴式身体活动监测仪很受欢迎,它可以提供比主观方法更准确的数据。本研究评估了一种新型、低成本的可穿戴身体活动监测器(Movband 3)相对于现有测量方法的有效性。方法:参与者(N = 19)在佩戴Movband 3和经过验证的Actigraph GT1M监测器的情况下完成了四个跑步机阶段(1.5,3.0,4.0,6.0 MPH)。记录耗氧量(VO2 ml/kg/min)和心率(次/min)。通过Pearson相关性评估Movband数据与既定测量之间的关系。对实际里程和移动里程进行了一致性测试。结果:有较大、阳性、显著(p <0.001)动带计数和活动图计数(r = 0.72)、摄氧量(r = 0.59)和心率(r = 0.63)之间关联的效应大小。还有一个巨大的、积极的、显著的(p <0.001)实际里程数和移动带里程之间的关联(r = 0.97)。然而,Movband与实际里程之间的差异(Δ)大于零的零假设(∆= 0.77±0.45英里或31.8%,t = 7.4, p <0.001)。结论:虽然有证据支持Movband 3在评估身体活动强度方面的有效性,但该设备并没有提供准确的旅行里程测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Implementation of a Triathlon Program for Primary School Students as part of Health and Physical Education Exploring the Use of Mindfulness-Based Meditation and Physical Activity to Reduce Stress in College Students The Effect of Acute Aerobic Exercise on Measures of Stress and Inflammation in Healthy Young Adults Measuring Energy Expenditure and Heart Rate during Maximum Aerobic Testing with the Apple Watch Series 7 A Preliminary Assessment of The Relationship Between Cellphone Use and Physical Activity, Sedentary Behavior, Anxiety, and Academic Performance in High School Students.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1