Cryosuction Experiments on Concrete Containing Ground Granulated Blast-Furnace Slag: Influence of Temperature, Air Entrainment And Salt

IF 0.7 Q4 CONSTRUCTION & BUILDING TECHNOLOGY Nordic Concrete Research Pub Date : 2023-07-01 DOI:10.2478/ncr-2022-0008
David Wahlbom, Katja Fridh
{"title":"Cryosuction Experiments on Concrete Containing Ground Granulated Blast-Furnace Slag: Influence of Temperature, Air Entrainment And Salt","authors":"David Wahlbom, Katja Fridh","doi":"10.2478/ncr-2022-0008","DOIUrl":null,"url":null,"abstract":"Abstract Frost deterioration of concrete is an important durability issue for structures exposed to high degree of saturation, low temperatures and de-icers. The material can then be severely damaged with internal cracking and/or scaling of the surface, which can lead to e.g. reduced protection of the reinforcement and loss of load bearing capacity. Experiments with liquid uptake in concrete using different temperature cycles was made to study cryosuction. The material used was concrete with different air content and different replacement levels of ground granulated blast-furnace slag (GGBS). The concrete samples were preconditioned by capillary suction. Three temperature conditions were used: constant temperatures of +20 °C and -20 °C, and temperature that cycled between -20 °C and +20 °C. As liquid medium, deionized water and a 3% NaCl salt solution were used. Air entrainment generally increased the liquid uptake. The amount of GGBS and the NaCl concentration in the liquid did not have any significant impact on the liquid uptake in these experiments.","PeriodicalId":42762,"journal":{"name":"Nordic Concrete Research","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nordic Concrete Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/ncr-2022-0008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Frost deterioration of concrete is an important durability issue for structures exposed to high degree of saturation, low temperatures and de-icers. The material can then be severely damaged with internal cracking and/or scaling of the surface, which can lead to e.g. reduced protection of the reinforcement and loss of load bearing capacity. Experiments with liquid uptake in concrete using different temperature cycles was made to study cryosuction. The material used was concrete with different air content and different replacement levels of ground granulated blast-furnace slag (GGBS). The concrete samples were preconditioned by capillary suction. Three temperature conditions were used: constant temperatures of +20 °C and -20 °C, and temperature that cycled between -20 °C and +20 °C. As liquid medium, deionized water and a 3% NaCl salt solution were used. Air entrainment generally increased the liquid uptake. The amount of GGBS and the NaCl concentration in the liquid did not have any significant impact on the liquid uptake in these experiments.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
含磨粒高炉渣混凝土的低温吸力试验:温度、夹带空气和盐的影响
摘要混凝土冻损是暴露于高饱和度、低温和除冰剂环境下的结构的重要耐久性问题。然后,材料会因内部开裂和/或表面结垢而严重损坏,这可能导致例如增强的保护减少和承载能力的丧失。对不同温度循环下混凝土的吸液量进行了研究。采用不同空气含量的混凝土和不同置换水平的矿渣粉。采用毛细管吸力对混凝土试样进行预处理。使用了三种温度条件:恒定温度为+20°C和-20°C,温度在-20°C和+20°C之间循环。液体介质为去离子水和3% NaCl盐溶液。夹带空气一般会增加液体的吸收量。在这些实验中,液体中GGBS的添加量和NaCl浓度对液体吸收没有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Nordic Concrete Research
Nordic Concrete Research CONSTRUCTION & BUILDING TECHNOLOGY-
自引率
20.00%
发文量
8
期刊最新文献
Load Effects of ASR-induced Expansion in Reinforced Concrete and Their Consequences for Structural Assessment A Review on Fatigue Performance of Concrete Structures Part II, Material Parameters and Environmental Factors Chloride Ion Diffusion Resistance of Bulk Hydrophobic Concrete: Comparison of w/c and Dosages Requirements for Test Series for Relative Humidity Measurements to Calibrate Drying Time Simulation Model Assessment of Effective and Minimal Slab Widths for Evaluating the Shear Capacity of RC Overhang Slabs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1