Development and validation of stability indicating thin‐layer chromatography method for simultaneous estimation of Benidipine hydrochloride and Telmisartan

IF 1.3 Q4 CHEMISTRY, ANALYTICAL SEPARATION SCIENCE PLUS Pub Date : 2023-08-31 DOI:10.1002/sscp.202300075
Laxmibharti B. P. Mandal, Ketan Shah
{"title":"Development and validation of stability indicating thin‐layer chromatography method for simultaneous estimation of Benidipine hydrochloride and Telmisartan","authors":"Laxmibharti B. P. Mandal, Ketan Shah","doi":"10.1002/sscp.202300075","DOIUrl":null,"url":null,"abstract":"Abstract For the simultaneous estimation of Benidipine hydrochloride (BEN) and Telmisartan (TEL) in combined pharmaceutical dosage form, a stability‐indicating high‐performance thin‐layer chromatography (HPTLC) method has been developed and validated. It involves the use of HPTLC plates pre‐coated with silica gel 60F 254 and a mobile phase comprising of Methanol: Acetonitrile (1:9 v/v). The measurements of both drugs were performed at 237 nm. The drugs were subjected to acid‐alkali hydrolysis, photolytic, thermal, and oxidation degradation. The linearity of BEN was found to be between 200–1000 ng/band (R 2 = 0.9917), while for TEL, linearity was found to be between 2000 and 10000 ng/band (R 2 = 0.9979). The limit of detection and limit of quantitation were found to be 3.28 and 9.94 ng/spot for BEN and 158.79 and 481.17 ng/spot for TEL. The % relative standard deviation of the precision study was determined to be less than 2%. Various system suitability parameters were determined. The R f values of BEN and TEL were found to be 0.890 ± 0.0105 and 0.173 ± 0.0151, respectively. The resolution between BEN and TEL peak were found to be 4.48 and capacity factors were found to be 0.21 and 0.74 for BEN and TEL, respectively.","PeriodicalId":21639,"journal":{"name":"SEPARATION SCIENCE PLUS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEPARATION SCIENCE PLUS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/sscp.202300075","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract For the simultaneous estimation of Benidipine hydrochloride (BEN) and Telmisartan (TEL) in combined pharmaceutical dosage form, a stability‐indicating high‐performance thin‐layer chromatography (HPTLC) method has been developed and validated. It involves the use of HPTLC plates pre‐coated with silica gel 60F 254 and a mobile phase comprising of Methanol: Acetonitrile (1:9 v/v). The measurements of both drugs were performed at 237 nm. The drugs were subjected to acid‐alkali hydrolysis, photolytic, thermal, and oxidation degradation. The linearity of BEN was found to be between 200–1000 ng/band (R 2 = 0.9917), while for TEL, linearity was found to be between 2000 and 10000 ng/band (R 2 = 0.9979). The limit of detection and limit of quantitation were found to be 3.28 and 9.94 ng/spot for BEN and 158.79 and 481.17 ng/spot for TEL. The % relative standard deviation of the precision study was determined to be less than 2%. Various system suitability parameters were determined. The R f values of BEN and TEL were found to be 0.890 ± 0.0105 and 0.173 ± 0.0151, respectively. The resolution between BEN and TEL peak were found to be 4.48 and capacity factors were found to be 0.21 and 0.74 for BEN and TEL, respectively.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
同时测定盐酸苯尼地平和替米沙坦含量的薄层色谱法的建立和稳定性验证
摘要建立了一种稳定性指示的高效薄层色谱(HPTLC)方法,用于同时测定盐酸苯尼地平(BEN)和替米沙坦(TEL)复方剂型的含量。它涉及使用预涂有硅胶60f254的HPTLC板和由甲醇:乙腈(1:9 v/v)组成的流动相。两种药物的测定均在237 nm下进行。药物经过酸碱水解、光解、热降解和氧化降解。BEN的线性关系为200 ~ 1000 ng/波段(r2 = 0.9917), TEL的线性关系为2000 ~ 10000 ng/波段(r2 = 0.9979)。BEN的检出限和定量限分别为3.28和9.94 ng/点,TEL的检出限和定量限分别为158.79和481.17 ng/点,精密度研究的相对标准偏差小于2%。确定了系统的各种适宜性参数。BEN和TEL的R f值分别为0.890±0.0105和0.173±0.0151。BEN和TEL的峰值分辨率分别为4.48,容量因子分别为0.21和0.74。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
SEPARATION SCIENCE PLUS
SEPARATION SCIENCE PLUS CHEMISTRY, ANALYTICAL-
CiteScore
1.90
自引率
9.10%
发文量
111
期刊最新文献
Removal of Residual DNA and Host Cell Proteins for the Purification of Recombinant Staphylokinase Expressed in Escherichia coli Green Analytical Approach for HPLC Method Development for Quantification of Sorafenib and Its Pharmacopeia Impurities: LC–MS/MS Characterization and Toxicity Prediction of Stress Degradation Products A Cartridge Structure Facilitates Clinical Mass Spectrometry Pretreatment and Can be Integrated Into a High‐Throughput Instrument Comparison of Polysaccharide Profiles of Different Seaweeds Based on Ion Chromatography and Ultrahigh‐Performance Liquid Chromatography Quantification of Recycled Polypropylene Stabilizers for Quality Control by Liquid Chromatography–Tandem Mass Spectrometry Using Simple, Fast and Efficient Ultrasonic Extraction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1