Guobo Wang, Yao Wang, Jianning Wang, Zhengfang Dong
{"title":"Shaking table test on seismic responses of asymmetrical underground subway stations","authors":"Guobo Wang, Yao Wang, Jianning Wang, Zhengfang Dong","doi":"10.1680/jphmg.22.00071","DOIUrl":null,"url":null,"abstract":"Currently, many subway stations are designed symmetrically and less attention has been paid to asymmetrical stations. The middle column of the asymmetric underground structure is offset to one side, which is not conducive to load-bearing in strong earthquakes and is prone to damage. In this study, shaking table tests of a soil-symmetrical station and a soil-asymmetrical station were designed and conducted. A numerical model of soil-structure interaction system was established, and the feasibility of the simulation method was verified. Then, the seismic responses of two kinds of stations were discussed and analyzed. The results show that the dynamic response of both symmetrical and asymmetrical stations increases with the increase of loading seismic intensity. Influenced by the size effect of the model test, there is less difference between the two models in their dynamic response. From the perspective of internal force and relative deformation, the response of asymmetrical station is greater than that of symmetrical station, which adequately reflects the disadvantage of asymmetrical structure in seismic design.","PeriodicalId":48816,"journal":{"name":"International Journal of Physical Modelling in Geotechnics","volume":"160 10","pages":"0"},"PeriodicalIF":1.2000,"publicationDate":"2023-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Physical Modelling in Geotechnics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1680/jphmg.22.00071","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Currently, many subway stations are designed symmetrically and less attention has been paid to asymmetrical stations. The middle column of the asymmetric underground structure is offset to one side, which is not conducive to load-bearing in strong earthquakes and is prone to damage. In this study, shaking table tests of a soil-symmetrical station and a soil-asymmetrical station were designed and conducted. A numerical model of soil-structure interaction system was established, and the feasibility of the simulation method was verified. Then, the seismic responses of two kinds of stations were discussed and analyzed. The results show that the dynamic response of both symmetrical and asymmetrical stations increases with the increase of loading seismic intensity. Influenced by the size effect of the model test, there is less difference between the two models in their dynamic response. From the perspective of internal force and relative deformation, the response of asymmetrical station is greater than that of symmetrical station, which adequately reflects the disadvantage of asymmetrical structure in seismic design.
期刊介绍:
International Journal of Physical Modelling in Geotechnics contains the latest research and analysis in all areas of physical modelling at any scale, including modelling at single gravity and at multiple gravities on a centrifuge, shaking table and pressure chamber testing and geoenvironmental experiments.