Factors Associated with Successful First-attempt Puncture in Pediatric Patients Undergoing Ultrasound-guided Peripherally Inserted Central Catheter

IF 0.4 4区 医学 Q4 PEDIATRICS Iranian Journal of Pediatrics Pub Date : 2023-02-09 DOI:10.5812/ijp-130372
Midan Zhang, Xiaofei Chen, Hongqin Zhou, Meifang Xu
{"title":"Factors Associated with Successful First-attempt Puncture in Pediatric Patients Undergoing Ultrasound-guided Peripherally Inserted Central Catheter","authors":"Midan Zhang, Xiaofei Chen, Hongqin Zhou, Meifang Xu","doi":"10.5812/ijp-130372","DOIUrl":null,"url":null,"abstract":"Background: Peripherally inserted central catheter (PICC) is an alternative to central venous cannulation. This study aimed to identify factors associated with first-attempt success rate in children undergoing PICC insertion. Methods: This retrospective study included pediatric patients who underwent PICC placement at the Children’s Hospital of Zhejiang (1/2020-12/2020). The successful puncture was defined as smooth blood return and insertion of the guide wire. Clinical data were collected, and factors associated with first-attempt success were identified by logistic regression analyses. Results: The final analysis included 640 children (360 males, 56.2%). Successful puncture at the first attempt was achieved in 380 (59.4%) patients. Multivariate logistic regression revealed that being uncooperative after sedation (OR = 2.745, 95%CI: 1.028 - 7.331, P = 0.044), being cooperative after sedation (OR = 0.318, 95%CI: 0.128–0.791, P = 0.014), target vein depth (0.5 - 1 vs. ≤ 0.5: OR = 1.715, 95%CI: 1.081–2.720, P = 0.022; 1.1-1.5 vs. ≤ 0.5: OR = 3.036, 95%CI: 1.166 - 7.903, P = 0.023; > 1.5 vs. ≤ 0.5: OR = 10.453, 95%CI: 2.366 - 46.139, P = 0.002), target vein diameter (2.0 - 2.9 vs. ≤ 2: OR = 0.313, 95%CI: 0.180 - 0.545, P < 0.001; ≥ 3 vs. ≤ 2: OR = 0.122, 95%CI: 0.055 - 0.272, P < 0.001), and 3F catheter specification (vs. 1.9F: OR = 2.057, 95%CI: 1.069 - 3.958, P = 0.031) were independently associated with puncture failure at the first attempt. Conclusions: The degree of cooperation, target vein diameter and depth, and catheter specification were independently associated with the first-attempt success rate.","PeriodicalId":14593,"journal":{"name":"Iranian Journal of Pediatrics","volume":"519 1","pages":"0"},"PeriodicalIF":0.4000,"publicationDate":"2023-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Pediatrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5812/ijp-130372","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Peripherally inserted central catheter (PICC) is an alternative to central venous cannulation. This study aimed to identify factors associated with first-attempt success rate in children undergoing PICC insertion. Methods: This retrospective study included pediatric patients who underwent PICC placement at the Children’s Hospital of Zhejiang (1/2020-12/2020). The successful puncture was defined as smooth blood return and insertion of the guide wire. Clinical data were collected, and factors associated with first-attempt success were identified by logistic regression analyses. Results: The final analysis included 640 children (360 males, 56.2%). Successful puncture at the first attempt was achieved in 380 (59.4%) patients. Multivariate logistic regression revealed that being uncooperative after sedation (OR = 2.745, 95%CI: 1.028 - 7.331, P = 0.044), being cooperative after sedation (OR = 0.318, 95%CI: 0.128–0.791, P = 0.014), target vein depth (0.5 - 1 vs. ≤ 0.5: OR = 1.715, 95%CI: 1.081–2.720, P = 0.022; 1.1-1.5 vs. ≤ 0.5: OR = 3.036, 95%CI: 1.166 - 7.903, P = 0.023; > 1.5 vs. ≤ 0.5: OR = 10.453, 95%CI: 2.366 - 46.139, P = 0.002), target vein diameter (2.0 - 2.9 vs. ≤ 2: OR = 0.313, 95%CI: 0.180 - 0.545, P < 0.001; ≥ 3 vs. ≤ 2: OR = 0.122, 95%CI: 0.055 - 0.272, P < 0.001), and 3F catheter specification (vs. 1.9F: OR = 2.057, 95%CI: 1.069 - 3.958, P = 0.031) were independently associated with puncture failure at the first attempt. Conclusions: The degree of cooperation, target vein diameter and depth, and catheter specification were independently associated with the first-attempt success rate.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声引导下周围置管患儿首次穿刺成功的相关因素
背景:外周置管中心导管(PICC)是一种替代中心静脉插管的方法。本研究旨在确定与儿童PICC置入首次成功率相关的因素。方法:本回顾性研究纳入了在浙江省儿童医院(2020年1月- 2020年12月)接受PICC安置的儿童患者。穿刺成功的定义是血液顺利回流并插入导丝。收集临床资料,并通过逻辑回归分析确定与首次尝试成功相关的因素。结果:最终纳入儿童640例,其中男性360例,占56.2%。首次穿刺成功380例(59.4%)。多因素logistic回归分析显示:镇静后不配合(OR = 2.745, 95%CI: 1.028 ~ 7.331, P = 0.044)、镇静后配合(OR = 0.318, 95%CI: 0.128 ~ 0.791, P = 0.014)、目标静脉深度(0.5 ~ 1 vs.≤0.5:OR = 1.715, 95%CI: 1.081 ~ 2.720, P = 0.022;1.1 ~ 1.5 vs.≤0.5:OR = 3.036, 95%CI: 1.166 ~ 7.903, P = 0.023;比;1.5 vs.≤0.5:OR = 10.453, 95%CI: 2.366 ~ 46.139, P = 0.002),靶静脉直径(2.0 ~ 2.9 vs.≤2:OR = 0.313, 95%CI: 0.180 ~ 0.545, P <0.001;≥3 vs.≤2:OR = 0.122, 95%CI: 0.055 - 0.272, P <0.001)和3F导管规格(vs. 1.9F: OR = 2.057, 95%CI: 1.069 - 3.958, P = 0.031)与首次穿刺失败独立相关。结论:配合程度、靶静脉直径和深度、导管规格与首次尝试成功率独立相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.90
自引率
20.00%
发文量
75
审稿时长
6-12 weeks
期刊介绍: Iranian Journal of Pediatrics (Iran J Pediatr) is a peer-reviewed medical publication. The purpose of Iran J Pediatr is to increase knowledge, stimulate research in all fields of Pediatrics, and promote better management of pediatric patients. To achieve the goals, the journal publishes basic, biomedical, and clinical investigations on prevalent diseases relevant to pediatrics. The acceptance criteria for all papers are the quality and originality of the research and their significance to our readership. Except where otherwise stated, manuscripts are peer-reviewed by minimum three anonymous reviewers. The Editorial Board reserves the right to refuse any material for publication and advises that authors should retain copies of submitted manuscripts and correspondence as the material cannot be returned. Final acceptance or rejection rests with the Editors.
期刊最新文献
Meningitis Caused by the Rare Bacterium Elizabethkingia meningoseptica, in Only One Twin, Late Preterm Newborn, with Complications-Case Report Pediatric Cardiomyopathies from the Landscape of Inherited Metabolic Disorders in Southeastern Turkey Is the Early Postoperative Application of Fibrinolytic Agents Safe in Cases of Empyema? Microalbuminuria in Children with Type 1 Diabetes and Its Relationship with Body Mass Index, Hemoglobin A1c, and Age at Diabetes Onset The Relationship Between Attention Deficit-Hyperactivity Disorder and Kidney Disease in Children and Adolescents: An Emerging Area of Research
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1