Human factor ergonomic analysis of cervical cancer intracavitary therapy transport process based on Jack virtual simulation technology

{"title":"Human factor ergonomic analysis of cervical cancer intracavitary therapy transport process based on Jack virtual simulation technology","authors":"","doi":"10.23977/jemm.2023.080404","DOIUrl":null,"url":null,"abstract":"With the incidence of cervical cancer in women rising year by year, its impact on the physical and mental health of patients as well as their families is becoming more and more significant. At present, hospitals often use intracavitary radiation therapy, and intracavitary therapy transfer bed as a gynecological oncology intracavitary radiation medical auxiliary device plays an extremely important role. Therefore, for the design of intracavitary therapy transfer beds, the validation of man-machine adaptability can well help to optimize its structure. The paper firstly imports the three-dimensional model of intracavitary therapy transfer bed established in UG software into the ergonomics analysis software Jack; secondly, in the analysis environment, it establishes the human body model that conforms to the body dimensions of patients with cervical cancer as well as the human body model of healthcare workers; then, on this basis, it establishes the simulation model for the patient's posture of using the intracavitary therapy transfer bed as well as for different movements of the healthcare workers in the course of the treatment; finally, it analyzes the stresses of the patient's lower limbs, as well as the waist, back, and upper limbs of the healthcare workers through the simulation and analyzes the comfort of the patients and the healthcare personnel with respect to the different movements of the treatment task. The analysis of the simulation results can verify the rationality of the design of the intracavitary therapy transfer bed and the use of comfort, and at the same time, combined with the results of the analysis of the healthcare worker's working posture, to provide an analysis method for the structural optimization of the intracavitary therapy transfer bed.","PeriodicalId":32485,"journal":{"name":"Journal of Engineering Mechanics and Machinery","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Engineering Mechanics and Machinery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23977/jemm.2023.080404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

With the incidence of cervical cancer in women rising year by year, its impact on the physical and mental health of patients as well as their families is becoming more and more significant. At present, hospitals often use intracavitary radiation therapy, and intracavitary therapy transfer bed as a gynecological oncology intracavitary radiation medical auxiliary device plays an extremely important role. Therefore, for the design of intracavitary therapy transfer beds, the validation of man-machine adaptability can well help to optimize its structure. The paper firstly imports the three-dimensional model of intracavitary therapy transfer bed established in UG software into the ergonomics analysis software Jack; secondly, in the analysis environment, it establishes the human body model that conforms to the body dimensions of patients with cervical cancer as well as the human body model of healthcare workers; then, on this basis, it establishes the simulation model for the patient's posture of using the intracavitary therapy transfer bed as well as for different movements of the healthcare workers in the course of the treatment; finally, it analyzes the stresses of the patient's lower limbs, as well as the waist, back, and upper limbs of the healthcare workers through the simulation and analyzes the comfort of the patients and the healthcare personnel with respect to the different movements of the treatment task. The analysis of the simulation results can verify the rationality of the design of the intracavitary therapy transfer bed and the use of comfort, and at the same time, combined with the results of the analysis of the healthcare worker's working posture, to provide an analysis method for the structural optimization of the intracavitary therapy transfer bed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于Jack虚拟仿真技术的宫颈癌腔内治疗转运过程人因工效学分析
随着宫颈癌在女性中的发病率逐年上升,其对患者及其家属身心健康的影响也越来越显著。目前,医院常采用腔内放射治疗,而腔内治疗转移床作为妇科肿瘤腔内放射医疗辅助装置起着极其重要的作用。因此,对于腔内治疗转移床的设计,人机适应性的验证可以很好地帮助优化其结构。本文首先将在UG软件中建立的腔内治疗转移床三维模型导入到人体工程学分析软件Jack中;其次,在分析环境下,建立符合宫颈癌患者身体尺寸的人体模型以及医护人员的人体模型;然后在此基础上,建立了患者使用腔内治疗转移床时的体位以及医护人员在治疗过程中不同动作的仿真模型;最后,通过模拟分析患者下肢以及医护人员的腰、背、上肢的受力情况,分析患者和医护人员在不同的治疗任务动作下的舒适度。仿真结果的分析可以验证腔内治疗转移床设计的合理性和使用舒适性,同时结合医护人员工作姿势的分析结果,为腔内治疗转移床的结构优化提供分析方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
6
审稿时长
8 weeks
期刊最新文献
Research on a Universal No Tillage Seeder for Wheat and Corn Finite Element Analysis and Optimization Design of Automobile Exhaust Pipe Lifting Lugs The Processing Method of CNC Lathe Processing Technology for Complex Parts Improved Blade Element Theory and Autorotating Rotor Aerodynamic Characteristics Analysis Research on a Machine Measurement Calibration Method Based on Laser Displacement Measurement
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1