Complications of Implantable Cardioverter Defibrillator and Their Potential Risk Factors in Patients with Hypertrophic Cardiomyopathy

IF 1.8 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Cardiology Research and Practice Pub Date : 2023-11-13 DOI:10.1155/2023/4552100
Mohammad Taghi Hedayati Goudarzi, Maryam Moradi, Saeed Abrotan, Mehrdad Saravi, Hoda Shirafkan, Rana Irilouzadian, Hossein Salehi Omran
{"title":"Complications of Implantable Cardioverter Defibrillator and Their Potential Risk Factors in Patients with Hypertrophic Cardiomyopathy","authors":"Mohammad Taghi Hedayati Goudarzi, Maryam Moradi, Saeed Abrotan, Mehrdad Saravi, Hoda Shirafkan, Rana Irilouzadian, Hossein Salehi Omran","doi":"10.1155/2023/4552100","DOIUrl":null,"url":null,"abstract":"Background. Hypertrophic cardiomyopathy (HCM) has different complications such as cardiac arrhythmia and sudden cardiac death (SCD). Insertion of an implantable cardioverter defibrillator (ICD) is recommended for HCM patients who are at high risk of SCD and malignant arrhythmias, despite having their own potential complications. Hypothesis. We aimed to investigate the prevalence of different complications of ICD insertion and the impact of the potential influential baseline characteristics in a one-year follow-up period. Methods. This was a retrospective study with a total of 71 HCM patients with ICD insertion. We evaluated the prevalence of different complications of ICD implantation and the impact of baseline characteristics on the occurrence of ICD complications using multivariate regression analysis in three 4-month periods. Results. In a one-year follow-up, 13 patients (18.3%) experienced at least one of the complications including pneumothorax, lead failure, ICD infection, inappropriate shocks, perforation, and upper limb deep vein thrombosis (DVT) with no mortality. Inappropriate shocks were reported as the most common (11.3%) complication during this period, with a gradual increase in the second (4.2%) and third (5.6%) follow-up sessions. Among all of the baseline characteristics that were investigated in this study, a positive history of hypertension was the only risk factor with significant impact on the occurrence of complications ( <math xmlns=\"http://www.w3.org/1998/Math/MathML\" id=\"M1\"> <mi>P</mi> </math> = 0.01). Conclusion. We demonstrated the occurrence of complications during a one-year follow-up as 18.3% in HCM patients with ICD insertion. A positive history of hypertension was the only baseline characteristic affecting the occurrence of complications, and inappropriate shocks were the most common complication.","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2023-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology Research and Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2023/4552100","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background. Hypertrophic cardiomyopathy (HCM) has different complications such as cardiac arrhythmia and sudden cardiac death (SCD). Insertion of an implantable cardioverter defibrillator (ICD) is recommended for HCM patients who are at high risk of SCD and malignant arrhythmias, despite having their own potential complications. Hypothesis. We aimed to investigate the prevalence of different complications of ICD insertion and the impact of the potential influential baseline characteristics in a one-year follow-up period. Methods. This was a retrospective study with a total of 71 HCM patients with ICD insertion. We evaluated the prevalence of different complications of ICD implantation and the impact of baseline characteristics on the occurrence of ICD complications using multivariate regression analysis in three 4-month periods. Results. In a one-year follow-up, 13 patients (18.3%) experienced at least one of the complications including pneumothorax, lead failure, ICD infection, inappropriate shocks, perforation, and upper limb deep vein thrombosis (DVT) with no mortality. Inappropriate shocks were reported as the most common (11.3%) complication during this period, with a gradual increase in the second (4.2%) and third (5.6%) follow-up sessions. Among all of the baseline characteristics that were investigated in this study, a positive history of hypertension was the only risk factor with significant impact on the occurrence of complications ( P = 0.01). Conclusion. We demonstrated the occurrence of complications during a one-year follow-up as 18.3% in HCM patients with ICD insertion. A positive history of hypertension was the only baseline characteristic affecting the occurrence of complications, and inappropriate shocks were the most common complication.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肥厚性心肌病患者植入式心律转复除颤器的并发症及其潜在危险因素
背景。肥厚性心肌病(HCM)有不同的并发症,如心律失常和心脏性猝死(SCD)。对于SCD和恶性心律失常高风险的HCM患者,尽管存在潜在的并发症,但仍建议植入植入式心律转复除颤器(ICD)。假设。我们的目的是在一年的随访期间调查ICD插入的不同并发症的患病率以及潜在的影响基线特征的影响。方法。这是一项回顾性研究,共有71例植入ICD的HCM患者。我们通过3个4个月的多变量回归分析来评估ICD植入不同并发症的发生率以及基线特征对ICD并发症发生的影响。结果。在一年的随访中,13例患者(18.3%)出现了至少一种并发症,包括气胸、导联衰竭、ICD感染、不适当的电击、穿孔和上肢深静脉血栓形成(DVT),无死亡。在此期间,不适当的电击是最常见的并发症(11.3%),在第二次随访(4.2%)和第三次随访(5.6%)中逐渐增加。在本研究调查的所有基线特征中,高血压病史是唯一对并发症发生有显著影响的危险因素(P = 0.01)。结论。我们发现在一年的随访中,植入ICD的HCM患者的并发症发生率为18.3%。高血压病史是影响并发症发生的唯一基线特征,不适当的电击是最常见的并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Cardiology Research and Practice
Cardiology Research and Practice Medicine-Cardiology and Cardiovascular Medicine
CiteScore
4.40
自引率
0.00%
发文量
64
审稿时长
13 weeks
期刊介绍: Cardiology Research and Practice is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies that focus on the diagnosis and treatment of cardiovascular disease. The journal welcomes submissions related to systemic hypertension, arrhythmia, congestive heart failure, valvular heart disease, vascular disease, congenital heart disease, and cardiomyopathy.
期刊最新文献
Effects of Cycloergometer on Cardiopulmonary Function in Elderly Patients after Coronary Artery Bypass Grafting: Clinical Trial. Inhibiting H2AX Can Ameliorate Myocardial Ischemia/Reperfusion Injury by Regulating P53/JNK Signaling Pathway. Atrial Strain and Strain Rate in a General Population: Do These Measures Improve the Assessment of Elevated NT-proBNP Levels? The Pharmacological Mechanisms Underlying the Protective Effect of Ginsenoside Rg3 against Heart Failure. Beta-Thalassemia Major and Myocardial Iron Overload: A Longitudinal Study with Magnetic Resonance Imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1