Assessing the impact of ventilation systems on indoor air quality: a mock-up experiment in Dubai

IF 2.2 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Frontiers in Built Environment Pub Date : 2023-11-13 DOI:10.3389/fbuil.2023.1286053
Chuloh Jung, Gamal El Samanoudy, Nahla Alqassimi, Mohamed Sherzad
{"title":"Assessing the impact of ventilation systems on indoor air quality: a mock-up experiment in Dubai","authors":"Chuloh Jung, Gamal El Samanoudy, Nahla Alqassimi, Mohamed Sherzad","doi":"10.3389/fbuil.2023.1286053","DOIUrl":null,"url":null,"abstract":"Indoor Air Quality (IAQ) has become an important concern in Dubai, driven by public health awareness, environmental regulations, and government initiatives. The Dubai Municipality has introduced guidelines and standards for IAQ in residential and non-residential buildings, emphasizing ventilation, material selection, and testing protocols. IAQ monitoring and testing are encouraged, and public awareness campaigns educate individuals about IAQ and its impact on health. Green building regulations in Dubai also address IAQ considerations. The Dubai Municipality has comprehensively assessed IAQ in public buildings, leading to stringent regulations. However, research on IAQ improvement and challenges associated with apartment ventilation systems is limited. This study aims to evaluate the IAQ improvement and potential issues of a ventilation system in an apartment through a mock-up experiment. Factors such as air volume, ventilation system type, and supply/exhaust duct configuration are analyzed. The results show that installing a ventilation device with a ventilation rate of 0.3–0.8 times/h reduces Formaldehyde (HCHO) and Volatile Organic Compounds (VOCs) concentrations by 30%–50%. The IAQ improvement is not significantly influenced by air volume. Each room supply/exhaust method shows a 10% higher reduction in VOC concentrations than the supply/kitchen exhaust unit method. Preventing backflow and addressing cold drafts are recommended during ventilation system installation. Noise measurements comply with standards in most cases. These findings contribute to developing guidelines for ventilation system design and installation in apartments, promoting healthier indoor environments. Further research with a broader range of ventilation devices and real-world conditions is recommended to validate these findings.","PeriodicalId":37112,"journal":{"name":"Frontiers in Built Environment","volume":"80 12","pages":"0"},"PeriodicalIF":2.2000,"publicationDate":"2023-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Built Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fbuil.2023.1286053","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Indoor Air Quality (IAQ) has become an important concern in Dubai, driven by public health awareness, environmental regulations, and government initiatives. The Dubai Municipality has introduced guidelines and standards for IAQ in residential and non-residential buildings, emphasizing ventilation, material selection, and testing protocols. IAQ monitoring and testing are encouraged, and public awareness campaigns educate individuals about IAQ and its impact on health. Green building regulations in Dubai also address IAQ considerations. The Dubai Municipality has comprehensively assessed IAQ in public buildings, leading to stringent regulations. However, research on IAQ improvement and challenges associated with apartment ventilation systems is limited. This study aims to evaluate the IAQ improvement and potential issues of a ventilation system in an apartment through a mock-up experiment. Factors such as air volume, ventilation system type, and supply/exhaust duct configuration are analyzed. The results show that installing a ventilation device with a ventilation rate of 0.3–0.8 times/h reduces Formaldehyde (HCHO) and Volatile Organic Compounds (VOCs) concentrations by 30%–50%. The IAQ improvement is not significantly influenced by air volume. Each room supply/exhaust method shows a 10% higher reduction in VOC concentrations than the supply/kitchen exhaust unit method. Preventing backflow and addressing cold drafts are recommended during ventilation system installation. Noise measurements comply with standards in most cases. These findings contribute to developing guidelines for ventilation system design and installation in apartments, promoting healthier indoor environments. Further research with a broader range of ventilation devices and real-world conditions is recommended to validate these findings.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估通风系统对室内空气质量的影响:迪拜的一个模拟实验
在公众健康意识、环境法规和政府举措的推动下,室内空气质量(IAQ)已成为迪拜的一个重要问题。迪拜市政府推出了住宅和非住宅建筑的室内空气质量指南和标准,强调通风、材料选择和测试协议。鼓励对室内空气质量进行监测和测试,并开展提高公众认识运动,教育个人了解室内空气质量及其对健康的影响。迪拜的绿色建筑法规也解决了室内空气质量问题。迪拜市政府对公共建筑的室内空气质量进行了全面评估,从而制定了严格的规定。然而,对室内空气质量的改善和与公寓通风系统相关的挑战的研究是有限的。本研究旨在通过模拟实验,评估通风系统对公寓室内空气质量的改善和潜在问题。分析了风量、通风系统类型和送风/排风管道配置等因素。结果表明,安装通风装置,通风次数为0.3 ~ 0.8次/h,可使室内甲醛(HCHO)和挥发性有机物(VOCs)浓度降低30% ~ 50%。空气量对室内空气质量的改善影响不大。每个房间的供气/排风方法都比供气/厨房排风装置方法能多减少10%的VOC浓度。通风系统安装时,建议注意防回流和处理冷气流。在大多数情况下,噪音测量都符合标准。这些发现有助于制定公寓通风系统设计和安装指南,促进更健康的室内环境。建议进一步研究更广泛的通风装置和实际条件,以验证这些发现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Frontiers in Built Environment
Frontiers in Built Environment Social Sciences-Urban Studies
CiteScore
4.80
自引率
6.70%
发文量
266
期刊最新文献
A case study on the implementation of location tracking technologies for productivity monitoring: understanding workers’ acceptance and socio-technical implications A computational approach for categorizing street segments in urban street networks based on topological properties Ground response of rolling dynamic compaction—a finite element modelling approach Adapting to climate change: snow load assessment of snow galleries on the Iron Ore Line in Northern Sweden Combination of cellulose nanofiber and artificial fusion protein for biocementation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1