Towards Molecularly Imprinted Polypyrrole-Based Sensor for the Detection of Methylene Blue

IF 3.7 3区 工程技术 Q2 CHEMISTRY, ANALYTICAL Chemosensors Pub Date : 2023-10-26 DOI:10.3390/chemosensors11110549
Raimonda Boguzaite, Greta Pilvenyte, Vilma Ratautaite, Ernestas Brazys, Almira Ramanaviciene, Arunas Ramanavicius
{"title":"Towards Molecularly Imprinted Polypyrrole-Based Sensor for the Detection of Methylene Blue","authors":"Raimonda Boguzaite, Greta Pilvenyte, Vilma Ratautaite, Ernestas Brazys, Almira Ramanaviciene, Arunas Ramanavicius","doi":"10.3390/chemosensors11110549","DOIUrl":null,"url":null,"abstract":"This study is dedicated to molecularly imprinted polymer-based sensor development for methylene blue detection. The sensor was designed by molecular imprinting of polypyrrole with phenothiazine derivative methylene blue (MB) as a template molecule. The molecularly imprinted polymer (MIP) was deposited directly on the surface of the indium tin oxide-coated glass electrode by potential cycling. Different deposition conditions, the layer’s durability, and thickness impact were analysed. The working electrodes were coated with molecularly imprinted and non-imprinted polymer layers. Potential pulse chronoamperometry and cyclic voltammetry were used to study these layers. Scanning electron microscopy was used to determine the surface morphology of the polymer layers. The change in optical absorption was used as an analytical tool to evaluate the capability of the MIP layer to adsorb MB. Selectivity was monitored by tracking the optical absorption changes in the presence of Azure A. In the case of MB adsorption, linearity was observed at all evaluated calibration plots in the concentration range from 0.1 μM to 10 mM. The novelty of this article is based on the methodology in the fabrication process of the sensors for MB, where MB retains its native (non-polymerised) form during the deposition of the MIP composite.","PeriodicalId":10057,"journal":{"name":"Chemosensors","volume":"192 6","pages":"0"},"PeriodicalIF":3.7000,"publicationDate":"2023-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemosensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/chemosensors11110549","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study is dedicated to molecularly imprinted polymer-based sensor development for methylene blue detection. The sensor was designed by molecular imprinting of polypyrrole with phenothiazine derivative methylene blue (MB) as a template molecule. The molecularly imprinted polymer (MIP) was deposited directly on the surface of the indium tin oxide-coated glass electrode by potential cycling. Different deposition conditions, the layer’s durability, and thickness impact were analysed. The working electrodes were coated with molecularly imprinted and non-imprinted polymer layers. Potential pulse chronoamperometry and cyclic voltammetry were used to study these layers. Scanning electron microscopy was used to determine the surface morphology of the polymer layers. The change in optical absorption was used as an analytical tool to evaluate the capability of the MIP layer to adsorb MB. Selectivity was monitored by tracking the optical absorption changes in the presence of Azure A. In the case of MB adsorption, linearity was observed at all evaluated calibration plots in the concentration range from 0.1 μM to 10 mM. The novelty of this article is based on the methodology in the fabrication process of the sensors for MB, where MB retains its native (non-polymerised) form during the deposition of the MIP composite.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于分子印迹聚吡咯的亚甲基蓝检测传感器的研究
本研究致力于基于分子印迹聚合物的亚甲基蓝检测传感器的开发。以吩噻嗪衍生物亚甲基蓝(MB)为模板分子,对聚吡咯进行分子印迹设计。通过电位循环将分子印迹聚合物(MIP)直接沉积在氧化铟锡玻璃电极表面。分析了不同的沉积条件对镀层耐久性和厚度的影响。在工作电极上涂有分子印迹和非印迹聚合物层。用电位脉冲计时安培法和循环伏安法对这些层进行了研究。用扫描电镜测定了聚合物层的表面形貌。光学吸收的变化被用作评估MIP层吸附MB的能力的分析工具。通过跟踪Azure a存在时的光学吸收变化来监测选择性。在MB吸附的情况下,在0.1 μM至10 mM的浓度范围内,所有评估的校准图都观察到线性。本文的新颖之处在于基于MB传感器制造过程中的方法。其中MB在MIP复合材料沉积期间保持其原生(非聚合)形式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Chemosensors
Chemosensors Chemistry-Analytical Chemistry
CiteScore
5.00
自引率
9.50%
发文量
450
审稿时长
11 weeks
期刊介绍: Chemosensors (ISSN 2227-9040; CODEN: CHEMO9) is an international, scientific, open access journal on the science and technology of chemical sensors published quarterly online by MDPI.The journal is indexed in Scopus, SCIE (Web of Science), CAPlus / SciFinder, Inspec, Engineering Village and other databases.
期刊最新文献
Prostate Cancer Detection in Colombian Patients through E-Senses Devices in Exhaled Breath and Urine Samples Origami Paper-Based Electrochemical Immunosensor with Carbon Nanohorns-Decorated Nanoporous Gold for Zearalenone Detection Spectroscopy and Chemometrics for Conformity Analysis of e-Liquids: Illegal Additive Detection and Nicotine Characterization Nanorods Assembled Hierarchical Bi2S3 for Highly Sensitive Detection of Trace NO2 at Room Temperature Evaluation of the Essential Oil Composition of Five Thymus Species Native to Greece
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1