Polyphosphate-loaded silk fibroin membrane as hemostatic agent in oral surgery: a pilot study.

IF 3.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Implant Dentistry Pub Date : 2023-11-17 DOI:10.1186/s40729-023-00503-0
Zohal Popal, Katrin F Nickel, Michael Wöltje, Dilbar Aibibu, Christian Knipfer, Ralf Smeets, Thomas Renné
{"title":"Polyphosphate-loaded silk fibroin membrane as hemostatic agent in oral surgery: a pilot study.","authors":"Zohal Popal, Katrin F Nickel, Michael Wöltje, Dilbar Aibibu, Christian Knipfer, Ralf Smeets, Thomas Renné","doi":"10.1186/s40729-023-00503-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Post-interventional hemorrhage can result in serious complications, especially in patients with hemostatic disorders. Identification of safe and efficient local hemostatic agents is important, particularly in the context of an ageing society and the emergence of new oral anticoagulants. The aim of this in vitro study was to investigate the potential of silk fibroin membranes coated with the inorganic polymer polyphosphate (polyP) as a novel hemostatic device in oral surgery.</p><p><strong>Methods: </strong>Cocoons of the silkworm Bombyx mori were degummed and dissolved. Varying amounts of long-chain polyP (2-2000 µg/mm<sup>2</sup>) were adsorbed to the surface of silk fibroin membranes. Analysis of the procoagulant effect of polyP-coated silk membranes was performed using real-time thrombin generation assays in human plasma. Increasing concentrations of polyP (0.15-500 µg/ml) served as a positive control, while uncoated silk fibroin membranes were used as negative control.</p><p><strong>Results: </strong>PolyP-coated silk fibroin membranes triggered coagulation when compared to plasma samples and pure silk fibroin membranes. A polyP-dose-dependent effect of thrombin generation could be found with a maximum (ETP = 1525.7 nM⋅min, peak thrombin = 310.1 nM, time to peak = 9.8 min, lag time = 7.6 min.) at 200 µg/mm<sup>2</sup> of polymer loading on the silk fibroin membrane surface.</p><p><strong>Conclusions: </strong>In this study, it was demonstrated that silk fibroin membranes coated with polyP have the potential to act as a promising novel hemostatic device.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"9 1","pages":"44"},"PeriodicalIF":3.1000,"publicationDate":"2023-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10656390/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-023-00503-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Post-interventional hemorrhage can result in serious complications, especially in patients with hemostatic disorders. Identification of safe and efficient local hemostatic agents is important, particularly in the context of an ageing society and the emergence of new oral anticoagulants. The aim of this in vitro study was to investigate the potential of silk fibroin membranes coated with the inorganic polymer polyphosphate (polyP) as a novel hemostatic device in oral surgery.

Methods: Cocoons of the silkworm Bombyx mori were degummed and dissolved. Varying amounts of long-chain polyP (2-2000 µg/mm2) were adsorbed to the surface of silk fibroin membranes. Analysis of the procoagulant effect of polyP-coated silk membranes was performed using real-time thrombin generation assays in human plasma. Increasing concentrations of polyP (0.15-500 µg/ml) served as a positive control, while uncoated silk fibroin membranes were used as negative control.

Results: PolyP-coated silk fibroin membranes triggered coagulation when compared to plasma samples and pure silk fibroin membranes. A polyP-dose-dependent effect of thrombin generation could be found with a maximum (ETP = 1525.7 nM⋅min, peak thrombin = 310.1 nM, time to peak = 9.8 min, lag time = 7.6 min.) at 200 µg/mm2 of polymer loading on the silk fibroin membrane surface.

Conclusions: In this study, it was demonstrated that silk fibroin membranes coated with polyP have the potential to act as a promising novel hemostatic device.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
多磷酸负载丝素膜作为口腔外科止血剂的初步研究。
目的:介入后出血可导致严重的并发症,尤其是有止血功能障碍的患者。确定安全有效的局部止血剂非常重要,特别是在老龄化社会和新型口服抗凝剂出现的背景下。本体外研究的目的是探讨无机聚合物聚磷酸酯(polyP)包裹的丝素膜作为一种新型口腔手术止血装置的潜力。方法:对家蚕蚕茧进行脱胶和溶解。不同数量的长链息肉(2-2000µg/mm2)被吸附到丝素膜表面。采用实时凝血酶生成法分析poly -coated蚕丝膜的促凝作用。增加polyP浓度(0.15 ~ 500µg/ml)作为阳性对照,未包被丝素膜作为阴性对照。结果:与血浆样品和纯丝素膜相比,poly包被丝素膜触发凝血。在丝素膜表面负载200µg/mm2的聚合物时,凝血酶的产生具有poly -剂量依赖性,ETP = 1525.7 nM⋅min,凝血酶峰= 310.1 nM,峰时间= 9.8 min,滞后时间= 7.6 min。结论:本研究表明,息肉蛋白包被的丝素膜具有作为一种新型止血装置的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
期刊最新文献
In-vitro investigation of bone temperature changes in osteotomies performed with different brands of implant burs. A digital way to assess the stain parameters that lead to soft tissue blanching when delivering an implant-supported crown. Electroplated double-crowns on implants and teeth after up to 12 years- a retrospective clinical study. The impact of a 1 mm interimplant distance on the interproximal crestal bone height: a case report with a 10-year follow-up and literature review. Usefulness of a novel density measurement drill for evaluating cancellous bone density: correlation between CT value and drilling torque value in bovine ribs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1