Pacemaker dependency and conduction system recovery following transcatheter aortic valve implantation.

IF 1.4 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Minerva cardiology and angiology Pub Date : 2024-04-01 Epub Date: 2023-11-16 DOI:10.23736/S2724-5683.23.06273-7
Joseph Cosma, Alessandro Russo, Sofia Schino, Saverio Muscoli, Massimo Marchei, Marco DI Luozzo, Giuseppe Sangiorgi, Enrica G Mariano
{"title":"Pacemaker dependency and conduction system recovery following transcatheter aortic valve implantation.","authors":"Joseph Cosma, Alessandro Russo, Sofia Schino, Saverio Muscoli, Massimo Marchei, Marco DI Luozzo, Giuseppe Sangiorgi, Enrica G Mariano","doi":"10.23736/S2724-5683.23.06273-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Transcatheter aortic valve implantation (TAVI)-related conduction system disorders are dynamic and may resolve over time. The purpose of this study was to investigate predictive factors of PM dependency among patients receiving permanent PM implantation after TAVI.</p><p><strong>Methods: </strong>We included 37 consecutive patients who underwent PPM implantation within six days after TAVI and who completed a 12-month follow-up. Patients were divided into two groups according to PPM dependency at follow-up: PPM-dependent group and non-PPM-dependent group. Device follow-ups were performed at one, six and 12 months.</p><p><strong>Results: </strong>There were no significant differences in either baseline clinical characteristics or procedural data and results. Analysis of baseline ECGs showed a statistical difference in PR interval (200.1±17.2 ms in the PPM-dependent group vs. 175±23.3 ms in the non PPM-dependent group [P=0,003]) and in the presence of RBBB (four patients in the PPM-dependent group vs. no patients in the non PPM-dependent group [P=0.02]) as well as QRS duration (117.3±27.4 ms in the PPM-dependent group and 99±18.3 msec in the non PPM-dependent group [P=0.04]).</p><p><strong>Conclusions: </strong>The rate of PPM dependency was significantly reduced at 12-month follow-up: from 62,2% at the time of implantation to 35,1%. PR interval and RBBB were the most important predictive factors for PPM dependency. Persistent AVB and alternating BBB were prevalent in the PPM-dependent group. In the absence of persistent AVB or alternating BBB, we suggest that patients without long PR interval and RBBB at baseline ECG be carefully evaluated before permanent PM implantation, as conduction system recovery is possible.</p>","PeriodicalId":18668,"journal":{"name":"Minerva cardiology and angiology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva cardiology and angiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S2724-5683.23.06273-7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Transcatheter aortic valve implantation (TAVI)-related conduction system disorders are dynamic and may resolve over time. The purpose of this study was to investigate predictive factors of PM dependency among patients receiving permanent PM implantation after TAVI.

Methods: We included 37 consecutive patients who underwent PPM implantation within six days after TAVI and who completed a 12-month follow-up. Patients were divided into two groups according to PPM dependency at follow-up: PPM-dependent group and non-PPM-dependent group. Device follow-ups were performed at one, six and 12 months.

Results: There were no significant differences in either baseline clinical characteristics or procedural data and results. Analysis of baseline ECGs showed a statistical difference in PR interval (200.1±17.2 ms in the PPM-dependent group vs. 175±23.3 ms in the non PPM-dependent group [P=0,003]) and in the presence of RBBB (four patients in the PPM-dependent group vs. no patients in the non PPM-dependent group [P=0.02]) as well as QRS duration (117.3±27.4 ms in the PPM-dependent group and 99±18.3 msec in the non PPM-dependent group [P=0.04]).

Conclusions: The rate of PPM dependency was significantly reduced at 12-month follow-up: from 62,2% at the time of implantation to 35,1%. PR interval and RBBB were the most important predictive factors for PPM dependency. Persistent AVB and alternating BBB were prevalent in the PPM-dependent group. In the absence of persistent AVB or alternating BBB, we suggest that patients without long PR interval and RBBB at baseline ECG be carefully evaluated before permanent PM implantation, as conduction system recovery is possible.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
经导管主动脉瓣植入术后心脏起搏器依赖与传导系统恢复。
背景:经导管主动脉瓣植入术(TAVI)相关的传导系统障碍是动态的,可能随着时间的推移而消退。本研究的目的是探讨TAVI术后永久性PM植入患者PM依赖的预测因素。方法:我们纳入了37例连续患者,他们在TAVI后6天内接受了PPM植入,并完成了12个月的随访。随访时根据PPM依赖程度将患者分为两组:PPM依赖组和非PPM依赖组。分别在1个月、6个月和12个月进行器械随访。结果:两组患者的基线临床特征、手术数据和结果均无显著差异。基线心电图分析显示,在PR间隔(ppm依赖组为200.1±17.2 ms,非ppm依赖组为175±23.3 ms [P= 0.003])、RBBB存在(ppm依赖组为4例,非ppm依赖组为无例[P=0.02])以及QRS持续时间(ppm依赖组为117.3±27.4 ms,非ppm依赖组为99±18.3 ms [P=0.04])方面存在统计学差异。结论:在12个月的随访中,PPM的依赖率明显降低,从植入时的62.2%下降到35.1%。PR间隔和RBBB是PPM依赖性最重要的预测因素。持久性AVB和交替性血脑屏障在ppm依赖组中普遍存在。在没有持续性AVB或交替血脑屏障的情况下,我们建议在永久性PM植入前仔细评估无长PR间期和基线心电图无RBBB的患者,因为传导系统可能恢复。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Minerva cardiology and angiology
Minerva cardiology and angiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.60
自引率
18.80%
发文量
118
期刊最新文献
Acurate neo2 is associated with a reduced inflammatory response in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation. Association between instantaneous heart rate sequence during the awake period and cardiovascular events: a study based on Sleep Heart Health Study. Cardiology 2.0: the (r)age of the machines? Clinical implications of Sokolow-Lyon voltage less than 3.5 mV in patients who have undergone transcatheter aortic valve replacement. Do publications of machine learning models justify the enthusiasm they generate?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1