Diagnostic accuracy of Apple Watch Series 6 recorded single-lead ECGs for identifying supraventricular tachyarrhythmias: a comparative analysis with invasive electrophysiological study.
Kivanc Yalin, Ali Ugur Soysal, Baris Ikitimur, Beyza Irem Yabaci, Sukriye Ebru Onder, Adem Atici, Hasan Tokdil, Gunduz Incesu, Hakan Yalman, Murat Cimci, Hakan Karpuz
{"title":"Diagnostic accuracy of Apple Watch Series 6 recorded single-lead ECGs for identifying supraventricular tachyarrhythmias: a comparative analysis with invasive electrophysiological study.","authors":"Kivanc Yalin, Ali Ugur Soysal, Baris Ikitimur, Beyza Irem Yabaci, Sukriye Ebru Onder, Adem Atici, Hasan Tokdil, Gunduz Incesu, Hakan Yalman, Murat Cimci, Hakan Karpuz","doi":"10.1007/s10840-023-01695-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The advancements in wearable technology have made the detection of arrhythmias more accessible. While smartwatches are commonly used to detect patients with atrial fibrillation, their effectiveness in the differential diagnosis of supraventricular tachycardias (SVT) lacks consensus.</p><p><strong>Methods: </strong>A study was conducted on 47 patients with documented SVTs on a 12-lead ECG. All patients in the cohort underwent electrophysiology study with induction of SVT. A 6th generation Apple Watch was used to record ECG tracings during baseline sinus rhythm and during induced SVT. Cardiology residents and attending cardiologists evaluated these recordings to diagnose the differential diagnosis of SVT.</p><p><strong>Results: </strong>The evaluation revealed 27 cases of typical atrioventricular nodal reentrant tachycardia (AVNRT), 11 cases of atrioventricular reentrant tachycardia (AVRT), and 9 cases of atrial tachycardia/atrial flutter (AT/AFL) among the induced tachycardias. Attending physicians achieved an accuracy of 66.0 to 76.6%, and residents demonstrated accuracy rates between 68.1 and 74.5%. Interrater reliability was assessed using Fleiss's Kappa method, resulting in a moderate level of agreement between residents (Kappa = 0.465, p < 0.001, 95% CI 0.30-0.63) and attendings (Kappa = 0.519, p < 0.001, 95% CI 0.35-0.68). The overall Kappa value was 0.417 (p < 0.001, 95% CI 0.34-0.49).</p><p><strong>Conclusions: </strong>Smartwatch recordings demonstrate moderate feasibility in diagnosing SVT when following a pre-specified algorithm. However, this diagnostic performance was lower than the accuracy obtained from 12-lead ECG tracings when blinded to procedure outcomes.</p>","PeriodicalId":16202,"journal":{"name":"Journal of Interventional Cardiac Electrophysiology","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Interventional Cardiac Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10840-023-01695-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The advancements in wearable technology have made the detection of arrhythmias more accessible. While smartwatches are commonly used to detect patients with atrial fibrillation, their effectiveness in the differential diagnosis of supraventricular tachycardias (SVT) lacks consensus.
Methods: A study was conducted on 47 patients with documented SVTs on a 12-lead ECG. All patients in the cohort underwent electrophysiology study with induction of SVT. A 6th generation Apple Watch was used to record ECG tracings during baseline sinus rhythm and during induced SVT. Cardiology residents and attending cardiologists evaluated these recordings to diagnose the differential diagnosis of SVT.
Results: The evaluation revealed 27 cases of typical atrioventricular nodal reentrant tachycardia (AVNRT), 11 cases of atrioventricular reentrant tachycardia (AVRT), and 9 cases of atrial tachycardia/atrial flutter (AT/AFL) among the induced tachycardias. Attending physicians achieved an accuracy of 66.0 to 76.6%, and residents demonstrated accuracy rates between 68.1 and 74.5%. Interrater reliability was assessed using Fleiss's Kappa method, resulting in a moderate level of agreement between residents (Kappa = 0.465, p < 0.001, 95% CI 0.30-0.63) and attendings (Kappa = 0.519, p < 0.001, 95% CI 0.35-0.68). The overall Kappa value was 0.417 (p < 0.001, 95% CI 0.34-0.49).
Conclusions: Smartwatch recordings demonstrate moderate feasibility in diagnosing SVT when following a pre-specified algorithm. However, this diagnostic performance was lower than the accuracy obtained from 12-lead ECG tracings when blinded to procedure outcomes.
期刊介绍:
The Journal of Interventional Cardiac Electrophysiology is an international publication devoted to fostering research in and development of interventional techniques and therapies for the management of cardiac arrhythmias. It is designed primarily to present original research studies and scholarly scientific reviews of basic and applied science and clinical research in this field. The Journal will adopt a multidisciplinary approach to link physical, experimental, and clinical sciences as applied to the development of and practice in interventional electrophysiology. The Journal will examine techniques ranging from molecular, chemical and pharmacologic therapies to device and ablation technology. Accordingly, original research in clinical, epidemiologic and basic science arenas will be considered for publication. Applied engineering or physical science studies pertaining to interventional electrophysiology will be encouraged. The Journal is committed to providing comprehensive and detailed treatment of major interventional therapies and innovative techniques in a structured and clinically relevant manner. It is directed at clinical practitioners and investigators in the rapidly growing field of interventional electrophysiology. The editorial staff and board reflect this bias and include noted international experts in this area with a wealth of expertise in basic and clinical investigation. Peer review of all submissions, conflict of interest guidelines and periodic editorial board review of all Journal policies have been established.