{"title":"A weighing method for measuring nitrous oxide leakage from hospital manifold-pipeline networks.","authors":"Steven J Gaff, Victor X Chen, Eugenie Kayak","doi":"10.1177/0310057X231198123","DOIUrl":null,"url":null,"abstract":"<p><p>Nitrous oxide is a potent greenhouse gas and ozone-depleting agent with a long atmospheric lifetime. Several previous reports indicate that over half of supplied nitrous oxide is wasted from leaking manifold-pipeline systems infrastructure prior to patient use, and that remediating leaks can have significant environmental benefits. We describe an accurate, simple and cost-effective cylinder weighing method to quantify nitrous oxide leak from the manifold-pipeline network at our tertiary non-obstetric facility. Nitrous oxide cylinder depletion was prospectively compared with clinical usage derived from the electronic medical record over an 18-day period. A total of 1932 l (3.62 kg) of nitrous oxide was used in 35 operating theatre cases during the period. This was only 16.5% of actual cylinder depletion (11,686 l; 21.88 kg), indicating that 83.5% (9754 l; 18.26 kg) of nitrous oxide had leaked to the atmosphere (376 ml/minute; 22.6 l/hour; 542 l/day). The fraction of nitrous oxide wasted was consistent with a retrospective analysis of the previous 2-year period at the site that compared purchasing records with estimated clinical use. If maintained over a year, the leak would be equivalent to 101 tonnes of carbon dioxide per annum.</p>","PeriodicalId":7746,"journal":{"name":"Anaesthesia and Intensive Care","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesia and Intensive Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/0310057X231198123","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Nitrous oxide is a potent greenhouse gas and ozone-depleting agent with a long atmospheric lifetime. Several previous reports indicate that over half of supplied nitrous oxide is wasted from leaking manifold-pipeline systems infrastructure prior to patient use, and that remediating leaks can have significant environmental benefits. We describe an accurate, simple and cost-effective cylinder weighing method to quantify nitrous oxide leak from the manifold-pipeline network at our tertiary non-obstetric facility. Nitrous oxide cylinder depletion was prospectively compared with clinical usage derived from the electronic medical record over an 18-day period. A total of 1932 l (3.62 kg) of nitrous oxide was used in 35 operating theatre cases during the period. This was only 16.5% of actual cylinder depletion (11,686 l; 21.88 kg), indicating that 83.5% (9754 l; 18.26 kg) of nitrous oxide had leaked to the atmosphere (376 ml/minute; 22.6 l/hour; 542 l/day). The fraction of nitrous oxide wasted was consistent with a retrospective analysis of the previous 2-year period at the site that compared purchasing records with estimated clinical use. If maintained over a year, the leak would be equivalent to 101 tonnes of carbon dioxide per annum.
期刊介绍:
Anaesthesia and Intensive Care is an international journal publishing timely, peer reviewed articles that have educational value and scientific merit for clinicians and researchers associated with anaesthesia, intensive care medicine, and pain medicine.