Tenzing 7 delivery catheter with or without a leading microwire for single pass aspiration thrombectomy: A multicenter experience.

IF 1.5 4区 医学 Q4 CLINICAL NEUROLOGY Interventional Neuroradiology Pub Date : 2023-11-28 DOI:10.1177/15910199231216765
Daniel A Tonetti, Manisha Koneru, Meghna Bhattacharyya, Joey D English, Fabio Settecase, Warren T Kim, Jane Khalife, Pratit Patel, Ajith Thomas, Tudor Jovin, Ricardo Hanel, Victor H C Benalia, Gustavo M Cortez, Amin Aghaebrahim, Eric Sauvageau, Mohamad Abdalkader, Thanh N Nguyen, Piers Klein, Adam A Dmytriw, Hamza Shaikh
{"title":"Tenzing 7 delivery catheter with or without a leading microwire for single pass aspiration thrombectomy: A multicenter experience.","authors":"Daniel A Tonetti, Manisha Koneru, Meghna Bhattacharyya, Joey D English, Fabio Settecase, Warren T Kim, Jane Khalife, Pratit Patel, Ajith Thomas, Tudor Jovin, Ricardo Hanel, Victor H C Benalia, Gustavo M Cortez, Amin Aghaebrahim, Eric Sauvageau, Mohamad Abdalkader, Thanh N Nguyen, Piers Klein, Adam A Dmytriw, Hamza Shaikh","doi":"10.1177/15910199231216765","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Aspiration mechanical thrombectomy traditionally includes use of an inner microcatheter and leading microwire to navigate an aspiration catheter (AC) to the site of occlusion. Early clinical experience suggests that a leading microwire is often not needed with the Tenzing 7 (T7, Route 92 Medical, San Mateo, CA), a soft tapered tip ledge-reducing delivery catheter. This multicenter experience aims to describe AC delivery success in single-pass thrombectomy using T7 with and without a leading microwire.</p><p><strong>Methods: </strong>A retrospective review was conducted of consecutive patients who underwent single-pass thrombectomy with T7 at six institutions between 2020 and 2022. We examined the percentage of successful AC delivery, puncture-to-revascularization time, and procedural complication rate.</p><p><strong>Results: </strong>A leading microwire with T7 was used in 19/89 (21%) of patients, and it was not used with T7 in 70/89 (79%) of patients. Successful AC delivery was similar with and without microwires (97% vs. 90%, p = 0.15). Median puncture-to-revascularization times were similar (17 min microwire vs. 16 min no-microwire, p = 0.12). No complications were associated with microwire use; one (1.4%) patient had a T7-related vasospasm resolved with verapamil during thrombectomy without a leading microwire. Differences in complication rates were not statistically significant (p = 0.46).</p><p><strong>Conclusion: </strong>In our real-world clinical experience, leading microwire use was infrequently necessary with the T7 delivery catheter. Successful AC delivery and complication rates were similar with and without microwire use in single-pass T7 thrombectomies. Initial pass with T7 may be performed without use of leading microwire, reserving microwire use for refractory cases or known difficult-to-navigate vasculature.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199231216765","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Aspiration mechanical thrombectomy traditionally includes use of an inner microcatheter and leading microwire to navigate an aspiration catheter (AC) to the site of occlusion. Early clinical experience suggests that a leading microwire is often not needed with the Tenzing 7 (T7, Route 92 Medical, San Mateo, CA), a soft tapered tip ledge-reducing delivery catheter. This multicenter experience aims to describe AC delivery success in single-pass thrombectomy using T7 with and without a leading microwire.

Methods: A retrospective review was conducted of consecutive patients who underwent single-pass thrombectomy with T7 at six institutions between 2020 and 2022. We examined the percentage of successful AC delivery, puncture-to-revascularization time, and procedural complication rate.

Results: A leading microwire with T7 was used in 19/89 (21%) of patients, and it was not used with T7 in 70/89 (79%) of patients. Successful AC delivery was similar with and without microwires (97% vs. 90%, p = 0.15). Median puncture-to-revascularization times were similar (17 min microwire vs. 16 min no-microwire, p = 0.12). No complications were associated with microwire use; one (1.4%) patient had a T7-related vasospasm resolved with verapamil during thrombectomy without a leading microwire. Differences in complication rates were not statistically significant (p = 0.46).

Conclusion: In our real-world clinical experience, leading microwire use was infrequently necessary with the T7 delivery catheter. Successful AC delivery and complication rates were similar with and without microwire use in single-pass T7 thrombectomies. Initial pass with T7 may be performed without use of leading microwire, reserving microwire use for refractory cases or known difficult-to-navigate vasculature.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在单道抽吸取栓中使用或不使用前置微丝的Tenzing 7输尿管:多中心经验。
导读:传统的机械抽吸取栓包括使用内微导管和前导微丝引导抽吸导管(AC)到达闭塞部位。早期临床经验表明,Tenzing 7 (T7, Route 92 Medical, San Mateo, CA)通常不需要前置微丝,这是一种软锥形尖端减少壁架的输送导管。这个多中心的经验旨在描述在T7有或没有前置微丝的单通道血栓切除术中交流电输送的成功。方法:回顾性分析2020年至2022年6家机构连续接受T7单通取栓的患者。我们检查了AC输注成功率、穿刺至血运重建时间和手术并发症发生率。结果:19/89(21%)的患者使用前置微丝带T7, 70/89(79%)的患者未使用前置微丝带T7。有无微丝的交流电输送成功率相似(97% vs 90%, p = 0.15)。穿刺至血运重建的中位时间相似(微针置入17分钟vs无微针置入16分钟,p = 0.12)。使用微丝无并发症;1例(1.4%)患者在取栓过程中使用维拉帕米解决了t7相关的血管痉挛,没有使用前置微丝。两组并发症发生率差异无统计学意义(p = 0.46)。结论:根据我们的实际临床经验,T7输导导管很少需要使用前置微丝。在T7单道血栓切除术中,使用微丝或不使用微丝时,AC输注成功率和并发症发生率相似。T7的初始通径可以不使用导丝,保留微丝用于难固性病例或已知难以导航的血管系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Interventional Neuroradiology
Interventional Neuroradiology CLINICAL NEUROLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
3.60
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
期刊最新文献
Emergent endovascular treatment versus medical treatment for acute large vessel occlusions with nondisabling symptoms. Performance assessment of the Surpass Evolve flow diverter for the treatment of intracranial aneurysms: A systematic review and meta-analysis. Safety and efficacy of coated flow diverters in the treatment of cerebral aneurysms during single antiplatelet therapy: A multicenter study. Silk vista baby flow diversion beyond the circle of Willis: A single-center experience with long-term outcomes. WFITN 2024 - 17th Congress of World Federation of Interventional and Therapeutic Neuroradiology - October 6-10, 2024 - New York, USA.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1