Preliminary study on the short-term changes of pulmonary perfusion after a single balloon pulmonary angioplasty in patients with chronic thromboembolic pulmonary hypertension.
{"title":"Preliminary study on the short-term changes of pulmonary perfusion after a single balloon pulmonary angioplasty in patients with chronic thromboembolic pulmonary hypertension.","authors":"Peng Hou, Hai-Ming Chen, Si-Yan Lin, Wen-Liang Guo, Peng-Hao Chen, Jie-Long Lin, Xiao-Feng Wu, Chun-Li Liu, Xin-Lu Wang, Cheng Hong","doi":"10.1177/17534666231212307","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Little is known about immediate responses of blood perfusion to the balloon pulmonary angioplasty (BPA) procedure.</p><p><strong>Objectives: </strong>To investigate the changes in pulmonary perfusion of balloon-dilated vessels and untreated vessels with before, immediately after a single BPA and at follow-up.</p><p><strong>Design: </strong>Retrospective single-center cohort study.</p><p><strong>Methods: </strong>Patients who had chronic thromboembolic pulmonary hypertension (CTEPH) and completed the pulmonary perfusion single photon emission computed tomography (SPECT) imaging before, immediately after BPA and at follow-up were included. We evaluated the perfusion defects of both-lung, BPA target (balloon dilated) and non-target (untreated) vessel segments according to Begic 3-point scale in each lung segment.</p><p><strong>Results: </strong>Forty patients (40 BPA procedures) were included and were given next BPA after 89 (62-125) days. The hemodynamic parameters including mPAP, PVR, and RAP were significantly improved after a single BPA. Visual scoring results of pulmonary perfusion imaging in 40 BPAs showed the perfusion defect scores of target vessels reduced from 5.6 ± 2.6 to 4.2 ± 2.2 (<i>p</i> < 0.001) immediately after BPA, and then further diminished to 3.1 ± 1.9 (<i>p</i> < 0.001) at follow-up. While in the non-target vessels, the post-BPA perfusion defect scores did not change significantly (13.4 ± 4.7 <i>versus</i> 12.8 ± 4.6, <i>p</i> = 0.182), but tended to decrease at follow-up (12.2 ± 4.2). However, there were 17 BPAs of which the post-BPA perfusion defect scores of non-target vessels increased significantly (<i>p</i> < 0.001), but decreased at follow-up.</p><p><strong>Conclusion: </strong>In addition to improving the blood perfusion of target vessels, BPA also has a certain effect on the perfusion of some non-target vessels.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10697034/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17534666231212307","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Little is known about immediate responses of blood perfusion to the balloon pulmonary angioplasty (BPA) procedure.
Objectives: To investigate the changes in pulmonary perfusion of balloon-dilated vessels and untreated vessels with before, immediately after a single BPA and at follow-up.
Design: Retrospective single-center cohort study.
Methods: Patients who had chronic thromboembolic pulmonary hypertension (CTEPH) and completed the pulmonary perfusion single photon emission computed tomography (SPECT) imaging before, immediately after BPA and at follow-up were included. We evaluated the perfusion defects of both-lung, BPA target (balloon dilated) and non-target (untreated) vessel segments according to Begic 3-point scale in each lung segment.
Results: Forty patients (40 BPA procedures) were included and were given next BPA after 89 (62-125) days. The hemodynamic parameters including mPAP, PVR, and RAP were significantly improved after a single BPA. Visual scoring results of pulmonary perfusion imaging in 40 BPAs showed the perfusion defect scores of target vessels reduced from 5.6 ± 2.6 to 4.2 ± 2.2 (p < 0.001) immediately after BPA, and then further diminished to 3.1 ± 1.9 (p < 0.001) at follow-up. While in the non-target vessels, the post-BPA perfusion defect scores did not change significantly (13.4 ± 4.7 versus 12.8 ± 4.6, p = 0.182), but tended to decrease at follow-up (12.2 ± 4.2). However, there were 17 BPAs of which the post-BPA perfusion defect scores of non-target vessels increased significantly (p < 0.001), but decreased at follow-up.
Conclusion: In addition to improving the blood perfusion of target vessels, BPA also has a certain effect on the perfusion of some non-target vessels.