A Closed Contactless Method for Investigation of Thermophysical Properties of Metals and Alloys in the Temperature Range of 1000–2500 K

IF 0.4 4区 工程技术 Q4 ENGINEERING, MULTIDISCIPLINARY Instruments and Experimental Techniques Pub Date : 2023-12-04 DOI:10.1134/S002044122304005X
A. V. Rumyantsev, I. N. Pyatykh
{"title":"A Closed Contactless Method for Investigation of Thermophysical Properties of Metals and Alloys in the Temperature Range of 1000–2500 K","authors":"A. V. Rumyantsev,&nbsp;I. N. Pyatykh","doi":"10.1134/S002044122304005X","DOIUrl":null,"url":null,"abstract":"<p>A closed noncontact method of converging radial temperature waves generated by high-frequency induction modulated heating of a cylindrical sample, which is intended to study the thermophysical properties of metals and alloys at high temperatures, and an experimental setup for its implementation based on modern equipment are described. According to the experiment, the thermophysical parameters are determined with the following errors: 2% for the thermal diffusivity, 3% for the heat capacity, 5% for the thermal conductivity, 1.4% for the electrical resistivity, and 2% for the power. The following quantities were then calculated: the density, coefficient of volumetric thermal expansion, electron and lattice thermal conductivities, volumetric heat capacity, heat absorption coefficient, monochromatic and integral degrees of blackness, enthalpy, entropy, and Gibbs energy. When studying a substitution alloy and an interstitial alloy, the advantages of the closed method are shown on a specific example.</p>","PeriodicalId":587,"journal":{"name":"Instruments and Experimental Techniques","volume":"66 6","pages":"1118 - 1126"},"PeriodicalIF":0.4000,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instruments and Experimental Techniques","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1134/S002044122304005X","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

A closed noncontact method of converging radial temperature waves generated by high-frequency induction modulated heating of a cylindrical sample, which is intended to study the thermophysical properties of metals and alloys at high temperatures, and an experimental setup for its implementation based on modern equipment are described. According to the experiment, the thermophysical parameters are determined with the following errors: 2% for the thermal diffusivity, 3% for the heat capacity, 5% for the thermal conductivity, 1.4% for the electrical resistivity, and 2% for the power. The following quantities were then calculated: the density, coefficient of volumetric thermal expansion, electron and lattice thermal conductivities, volumetric heat capacity, heat absorption coefficient, monochromatic and integral degrees of blackness, enthalpy, entropy, and Gibbs energy. When studying a substitution alloy and an interstitial alloy, the advantages of the closed method are shown on a specific example.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
研究 1000-2500 K 温度范围内金属和合金热物理性质的封闭式非接触方法
本文介绍了一种通过对圆柱形样品进行高频感应调制加热而产生的径向温度波进行会聚的封闭式非接触方法,该方法旨在研究金属和合金在高温下的热物理性质。根据实验,热物理参数的测定误差如下:热扩散率 2%,热容量 3%,热导率 5%,电阻率 1.4%,功率 2%。然后计算出以下数量:密度、体积热膨胀系数、电子和晶格热导率、体积热容、吸热系数、单色黑度和积分黑度、焓、熵和吉布斯能。在研究置换合金和间隙合金时,通过一个具体实例展示了封闭方法的优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Instruments and Experimental Techniques
Instruments and Experimental Techniques 工程技术-工程:综合
CiteScore
1.20
自引率
33.30%
发文量
113
审稿时长
4-8 weeks
期刊介绍: Instruments and Experimental Techniques is an international peer reviewed journal that publishes reviews describing advanced methods for physical measurements and techniques and original articles that present techniques for physical measurements, principles of operation, design, methods of application, and analysis of the operation of physical instruments used in all fields of experimental physics and when conducting measurements using physical methods and instruments in astronomy, natural sciences, chemistry, biology, medicine, and ecology.
期刊最新文献
Measurement of Time Resolution of Scintillation Detectors with EQR-15 Silicon Photodetectors for the Time-of-Flight Neutron Detector of the BM@N Experiment Development of a High Granular TOF Neutron Detector for the BM@N Experiment A Scintillation Amplitude−Coordinate Spectrometer Broadband Receiver for MRI The Improvement of Temperature Sensitivity by Eliminating the Thermal Stress at the Interface of Fiber Bragg Gratings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1