Feasibility study of a novel robotic system for transperitoneal partial nephrectomy: An in vivo experimental animal study.

IF 1.4 Q3 UROLOGY & NEPHROLOGY Archivio Italiano di Urologia e Andrologia Pub Date : 2023-12-05 DOI:10.4081/aiua.2023.11852
Solon Faitatziadis, Vasileios Tatanis, Paraskevi Katsakiori, Angelis Peteinaris, Kristiana Gkeka, Athanasios Vagionis, Theodoros Spinos, Arman Tsaturyan, Theofanis Vrettos, Panagiotis Kallidonis, Jens-Uwe Stolzenburg, Evangelos Liatsikos
{"title":"Feasibility study of a novel robotic system for transperitoneal partial nephrectomy: An in vivo experimental animal study.","authors":"Solon Faitatziadis, Vasileios Tatanis, Paraskevi Katsakiori, Angelis Peteinaris, Kristiana Gkeka, Athanasios Vagionis, Theodoros Spinos, Arman Tsaturyan, Theofanis Vrettos, Panagiotis Kallidonis, Jens-Uwe Stolzenburg, Evangelos Liatsikos","doi":"10.4081/aiua.2023.11852","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the safety and feasibility of partial nephrectomy with the use of the novel robotic system in an in vivo animal model.</p><p><strong>Methods: </strong>Right partial nephrectomy was performed in female pigs by a surgical team consisting of one surgeon and one bedside assistant. Both were experienced in laparoscopic surgery and trained in the use of the novel robotic system. The partial nephrectomies were performed using four trocars (three trocars for the robotic arms and one as an assistant trocar). The completion of the operations, set-up time, operation time, warm ischemia time (WIT) and complication events were recorded. The decrease in all variables between the first and last operation was calculated.</p><p><strong>Results: </strong>In total, eight partial nephrectomies were performed in eight female pigs. All operations were successfully completed. The median set-up time was 19.5 (range, 15-30) minutes, while the estimated median operative time was 80.5 minutes (range, 59-114). The median WIT was 23.5 minutes (range, 17-32) and intra- or postoperative complications were not observed. All variables decreased in consecutive operations. More precisely, the decrease in the set-up time was calculated to 15 minutes between the first and third attempts. The operative time was reduced by 55 minutes between the first and last operation, while the WIT was decreased by 15 minutes during the consecutive attempts. No complications were noticed in any operation.</p><p><strong>Conclusions: </strong>Using the newly introduced robotic system, all the advantages of robotic surgery are optimized and incorporated, and partial nephrectomies can be performed in a safe and effective manner.</p>","PeriodicalId":46900,"journal":{"name":"Archivio Italiano di Urologia e Andrologia","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archivio Italiano di Urologia e Andrologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/aiua.2023.11852","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the safety and feasibility of partial nephrectomy with the use of the novel robotic system in an in vivo animal model.

Methods: Right partial nephrectomy was performed in female pigs by a surgical team consisting of one surgeon and one bedside assistant. Both were experienced in laparoscopic surgery and trained in the use of the novel robotic system. The partial nephrectomies were performed using four trocars (three trocars for the robotic arms and one as an assistant trocar). The completion of the operations, set-up time, operation time, warm ischemia time (WIT) and complication events were recorded. The decrease in all variables between the first and last operation was calculated.

Results: In total, eight partial nephrectomies were performed in eight female pigs. All operations were successfully completed. The median set-up time was 19.5 (range, 15-30) minutes, while the estimated median operative time was 80.5 minutes (range, 59-114). The median WIT was 23.5 minutes (range, 17-32) and intra- or postoperative complications were not observed. All variables decreased in consecutive operations. More precisely, the decrease in the set-up time was calculated to 15 minutes between the first and third attempts. The operative time was reduced by 55 minutes between the first and last operation, while the WIT was decreased by 15 minutes during the consecutive attempts. No complications were noticed in any operation.

Conclusions: Using the newly introduced robotic system, all the advantages of robotic surgery are optimized and incorporated, and partial nephrectomies can be performed in a safe and effective manner.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型机器人系统经腹膜肾部分切除术的可行性研究:体内实验动物研究。
目的:在活体动物模型中评估应用新型机器人系统进行部分肾切除术的安全性和可行性。方法:由一名外科医生和一名床边助理组成的手术小组对母猪进行右侧部分肾切除术。两人都有腹腔镜手术经验,并接受过使用新型机器人系统的培训。部分肾切除术使用四个套管针(三个套管针用于机械臂,一个作为辅助套管针)。记录手术完成情况、术前准备时间、手术时间、热缺血时间(WIT)及并发症发生情况。计算第一次和最后一次操作之间所有变量的减少。结果:8头母猪共行8例部分肾切除术。所有操作均成功完成。中位设置时间为19.5分钟(15-30分钟),而估计中位手术时间为80.5分钟(59-114分钟)。中位WIT为23.5分钟(范围17-32),未观察到术中或术后并发症。在连续操作中,所有变量均下降。更准确地说,第一次和第三次尝试之间的设置时间减少了15分钟。在第一次和最后一次手术之间,手术时间减少了55分钟,而在连续尝试期间,WIT减少了15分钟。所有手术均无并发症。结论:使用新引进的机器人系统,优化并融合了机器人手术的所有优点,可以安全有效地进行部分肾切除术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.10
自引率
35.70%
发文量
72
审稿时长
10 weeks
期刊最新文献
"Bottoms-up" minimally-invasive approach to inguinal lymph node dissection for penile cancer management. A single-center comparative study versus open approach and review. A systematic review and meta-analysis of short- and long-term complications of early versus delayed penile prosthesis implantation in patients with ischemic priapism. Adverse events related to laser fibers and laser machines during ureteroscopy and stone lithotripsy: Insights from an updated 10-year analysis of the US MAUDE database. Can serum 17-hydroxy progesterone predict an improvement in semen parameters following micro-varicocelectomy? A prospective study. CFTR Exon 10 deleterious mutations in patients with congenital bilateral absence of vas deferens in a cohort of Pakistani patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1