Proposal for vertical distribution of seismic design load and equivalent isolation ratio for seismically isolated buildings with multiple types of dampers: Vertical distribution of seismic design load for seismically isolated buildings corresponding to diversity of seismic isolation devices, part 2

IF 0.8 0 ARCHITECTURE Japan Architectural Review Pub Date : 2023-12-10 DOI:10.1002/2475-8876.12422
Masahito Kobayashi, Yusuke Komachi
{"title":"Proposal for vertical distribution of seismic design load and equivalent isolation ratio for seismically isolated buildings with multiple types of dampers: Vertical distribution of seismic design load for seismically isolated buildings corresponding to diversity of seismic isolation devices, part 2","authors":"Masahito Kobayashi,&nbsp;Yusuke Komachi","doi":"10.1002/2475-8876.12422","DOIUrl":null,"url":null,"abstract":"<p>As previously reported, we have proposed a vertical distribution of seismic design load for seismically isolated buildings (SIBs) corresponding to diversity of seismic isolation devices such as hysteretic dampers and velocity-dependent dampers. This proposed seismic design load is obtained from the relationship between response amplification caused by higher mode responses and the isolation ratio which represents structural characteristics of SIBs. In this paper, we build a concept of the equivalent isolation ratio which has applicability to various dampers in order to simplify an evaluation formula of vertical distribution of seismic design load. Moreover, an effect of the combined application of various dampers on vertical distribution of shear force coefficient of SIBs is analyzed on the basis of the equivalent isolation ratio.</p>","PeriodicalId":42793,"journal":{"name":"Japan Architectural Review","volume":"7 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2023-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/2475-8876.12422","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japan Architectural Review","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/2475-8876.12422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"ARCHITECTURE","Score":null,"Total":0}
引用次数: 0

Abstract

As previously reported, we have proposed a vertical distribution of seismic design load for seismically isolated buildings (SIBs) corresponding to diversity of seismic isolation devices such as hysteretic dampers and velocity-dependent dampers. This proposed seismic design load is obtained from the relationship between response amplification caused by higher mode responses and the isolation ratio which represents structural characteristics of SIBs. In this paper, we build a concept of the equivalent isolation ratio which has applicability to various dampers in order to simplify an evaluation formula of vertical distribution of seismic design load. Moreover, an effect of the combined application of various dampers on vertical distribution of shear force coefficient of SIBs is analyzed on the basis of the equivalent isolation ratio.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
关于采用多种类型减震器的隔震建筑物地震设计荷载垂直分布和等效隔震率的建议:与隔震装置多样性相对应的隔震建筑物地震设计荷载垂直分布,第 2 部分
正如之前所报道的,我们提出了地震隔离建筑(SIBs)的地震设计荷载垂直分布,它与地震隔离装置(如滞回阻尼器和速度相关阻尼器)的多样性相对应。所提出的地震设计荷载是从高模态响应引起的响应放大与代表 SIB 结构特征的隔震比之间的关系中获得的。本文建立了适用于各种阻尼器的等效隔震比概念,以简化地震设计荷载垂直分布的评估公式。此外,在等效隔震比的基础上,还分析了各种阻尼器的组合应用对 SIB 剪力系数垂直分布的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.20
自引率
11.10%
发文量
58
审稿时长
15 weeks
期刊最新文献
Investigation of indoor microplastics in settled indoor house dust in single-person residential buildings in Japan An investigation of the effect of vibration duration on the evaluation of subjective responses to horizontal vibration Design process of the Memorial Cathedral for World Peace (1954), Hiroshima, by Togo Murano (Part 4): Formal manipulations observed in the process of working design and construction instruction of the cathedral (1948–1954) Communication behavior and space utilization of office workers in a research facility's activity-based workplace A new processing method of ground acceleration data for fast and accurate evaluation of maximum seismic structural response
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1