Rachel E.J. Besser, Anna E. Long, Katharine R. Owen, Rebecca Law, Jacqueline S. Birks, Olivia Pearce, Claire L. Williams, Claire L. Scudder, Timothy J. McDonald, John A. Todd
{"title":"Transdermal Blood Sampling for C-Peptide Is a Minimally Invasive, Reliable Alternative to Venous Sampling in Children and Adults With Type 1 Diabetes","authors":"Rachel E.J. Besser, Anna E. Long, Katharine R. Owen, Rebecca Law, Jacqueline S. Birks, Olivia Pearce, Claire L. Williams, Claire L. Scudder, Timothy J. McDonald, John A. Todd","doi":"10.2337/dc23-1379","DOIUrl":null,"url":null,"abstract":"OBJECTIVE C-peptide and islet autoantibodies are key type 1 diabetes biomarkers, typically requiring venous sampling, which limits their utility. We assessed transdermal capillary blood (TCB) collection as a practical alternative. RESEARCH DESIGN AND METHODS Ninety-one individuals (71 with type 1 diabetes, 20 controls; individuals with type 1 diabetes: aged median 14.8 years [interquartile range (IQR) 9.1–17.1], diabetes duration 4.0 years [1.5–7.7]; controls: 42.2 years [38.0–52.1]) underwent contemporaneous venous and TCB sampling for measurement of plasma C-peptide. Participants with type 1 diabetes also provided venous serum and plasma, and TCB plasma for measurement of autoantibodies to glutamate decarboxylase, islet antigen-2, and zinc transporter 8. The ability of TCB plasma to detect significant endogenous insulin secretion (venous C-peptide ≥200 pmol/L) was compared along with agreement in levels, using Bland-Altman. Venous serum was compared with venous and TCB plasma for detection of autoantibodies, using established thresholds. Acceptability was assessed by age-appropriate questionnaire. RESULTS Transdermal sampling took a mean of 2.35 min (SD 1.49). Median sample volume was 50 µL (IQR 40–50) with 3 of 91 (3.3%) failures, and 13 of 88 (14.7%) <35 µL. TCB C-peptide showed good agreement with venous plasma (mean venous ln[C-peptide] – TCB ln[C-peptide] = 0.008, 95% CI [−0.23, 0.29], with 100% [36 of 36] sensitivity/100% [50 of 50] specificity to detect venous C-peptide ≥200 pmol/L). Where venous serum in multiple autoantibody positive TCB plasma agreed in 22 of 32 (sensitivity 69%), comparative specificity was 35 of 36 (97%). TCB was preferred to venous sampling (type 1 diabetes: 63% vs. 7%; 30% undecided). CONCLUSIONS Transdermal capillary testing for C-peptide is a sensitive, specific, and acceptable alternative to venous sampling; TCB sampling for islet autoantibodies needs further assessment.","PeriodicalId":11140,"journal":{"name":"Diabetes Care","volume":"68 1","pages":""},"PeriodicalIF":14.8000,"publicationDate":"2023-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2337/dc23-1379","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
OBJECTIVE C-peptide and islet autoantibodies are key type 1 diabetes biomarkers, typically requiring venous sampling, which limits their utility. We assessed transdermal capillary blood (TCB) collection as a practical alternative. RESEARCH DESIGN AND METHODS Ninety-one individuals (71 with type 1 diabetes, 20 controls; individuals with type 1 diabetes: aged median 14.8 years [interquartile range (IQR) 9.1–17.1], diabetes duration 4.0 years [1.5–7.7]; controls: 42.2 years [38.0–52.1]) underwent contemporaneous venous and TCB sampling for measurement of plasma C-peptide. Participants with type 1 diabetes also provided venous serum and plasma, and TCB plasma for measurement of autoantibodies to glutamate decarboxylase, islet antigen-2, and zinc transporter 8. The ability of TCB plasma to detect significant endogenous insulin secretion (venous C-peptide ≥200 pmol/L) was compared along with agreement in levels, using Bland-Altman. Venous serum was compared with venous and TCB plasma for detection of autoantibodies, using established thresholds. Acceptability was assessed by age-appropriate questionnaire. RESULTS Transdermal sampling took a mean of 2.35 min (SD 1.49). Median sample volume was 50 µL (IQR 40–50) with 3 of 91 (3.3%) failures, and 13 of 88 (14.7%) <35 µL. TCB C-peptide showed good agreement with venous plasma (mean venous ln[C-peptide] – TCB ln[C-peptide] = 0.008, 95% CI [−0.23, 0.29], with 100% [36 of 36] sensitivity/100% [50 of 50] specificity to detect venous C-peptide ≥200 pmol/L). Where venous serum in multiple autoantibody positive TCB plasma agreed in 22 of 32 (sensitivity 69%), comparative specificity was 35 of 36 (97%). TCB was preferred to venous sampling (type 1 diabetes: 63% vs. 7%; 30% undecided). CONCLUSIONS Transdermal capillary testing for C-peptide is a sensitive, specific, and acceptable alternative to venous sampling; TCB sampling for islet autoantibodies needs further assessment.
期刊介绍:
The journal's overarching mission can be captured by the simple word "Care," reflecting its commitment to enhancing patient well-being. Diabetes Care aims to support better patient care by addressing the comprehensive needs of healthcare professionals dedicated to managing diabetes.
Diabetes Care serves as a valuable resource for healthcare practitioners, aiming to advance knowledge, foster research, and improve diabetes management. The journal publishes original research across various categories, including Clinical Care, Education, Nutrition, Psychosocial Research, Epidemiology, Health Services Research, Emerging Treatments and Technologies, Pathophysiology, Complications, and Cardiovascular and Metabolic Risk. Additionally, Diabetes Care features ADA statements, consensus reports, review articles, letters to the editor, and health/medical news, appealing to a diverse audience of physicians, researchers, psychologists, educators, and other healthcare professionals.