{"title":"Development of Vibratory Microinjection System for Instantaneous Cell Membrane Piercing in Cytoplasmic Microinjection into Fertilized Eggs","authors":"Fujio Miyawaki, Jun Hasegawa","doi":"10.3390/act12120448","DOIUrl":null,"url":null,"abstract":"To complete microinjection as quickly as possible, we have developed Vibratory Microinjection Systems (VMSs) that vibrate a micropipette in its longitudinal direction and can significantly reduce the time needed for pronuclear microinjection compared to ordinary (non-vibratory) microinjection. The longest breakdown of the time is the time required to pierce the cell membrane and the pronuclear membrane simultaneously. Because cytoplasmic microinjection, which pierces the cell membrane alone, is far more difficult and time-consuming than pronuclear microinjection, we next aimed to develop a VMS capable of penetrating the cell membrane instantly. In this new and latest version, two types of ultrasonic-wave vibrators were developed: the first for commercially available micropipettes (Femtotip) and the second for self-made micropipettes. The two vibrators differ only in their airtight structure, where the micropipettes connect to their respective vibrators: a female screw plus O-ring for the first vibrator (VMS6_1) and a silicone–-rubber tube for the second (VMS6_2). The tube-type joint used in VMS6_2 only slightly damped or amplified vibrations from the vibrator to the micropipette tip, propagating them much more accurately than the screw-type joint in VMS6_1. In addition, VMS6_2 significantly shortened the time taken to pierce the cell membrane of a fertilized egg: an average of 1.52 s (N = 410) vs. 3.62 s (N = 65) in VMS6_1. The VMS6_2 group achieved a piercing time of zero in 86.1% of the allocated eggs, while only 10.8% of the VMS6_1 group did. In each vibrator, we also compared vibratory microinjection (VM; N = 475) and ordinary microinjection (OM; N = 457), which uses injection pressure in place of vibration. None of the eggs in the OM group achieved the zero-second piercing time. Compared to the OM, the VM group showed a significantly shorter piercing time, 1.80 vs. 10.69 s on average, and a significantly better survival rate, 90.3 vs. 81.8% on average. VMS6_2 not only improved on the already demonstrated superiority of VM to OM but also enabled instantaneous piercing of the cell membrane.","PeriodicalId":48584,"journal":{"name":"Actuators","volume":"42 6","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2023-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Actuators","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/act12120448","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

To complete microinjection as quickly as possible, we have developed Vibratory Microinjection Systems (VMSs) that vibrate a micropipette in its longitudinal direction and can significantly reduce the time needed for pronuclear microinjection compared to ordinary (non-vibratory) microinjection. The longest breakdown of the time is the time required to pierce the cell membrane and the pronuclear membrane simultaneously. Because cytoplasmic microinjection, which pierces the cell membrane alone, is far more difficult and time-consuming than pronuclear microinjection, we next aimed to develop a VMS capable of penetrating the cell membrane instantly. In this new and latest version, two types of ultrasonic-wave vibrators were developed: the first for commercially available micropipettes (Femtotip) and the second for self-made micropipettes. The two vibrators differ only in their airtight structure, where the micropipettes connect to their respective vibrators: a female screw plus O-ring for the first vibrator (VMS6_1) and a silicone–-rubber tube for the second (VMS6_2). The tube-type joint used in VMS6_2 only slightly damped or amplified vibrations from the vibrator to the micropipette tip, propagating them much more accurately than the screw-type joint in VMS6_1. In addition, VMS6_2 significantly shortened the time taken to pierce the cell membrane of a fertilized egg: an average of 1.52 s (N = 410) vs. 3.62 s (N = 65) in VMS6_1. The VMS6_2 group achieved a piercing time of zero in 86.1% of the allocated eggs, while only 10.8% of the VMS6_1 group did. In each vibrator, we also compared vibratory microinjection (VM; N = 475) and ordinary microinjection (OM; N = 457), which uses injection pressure in place of vibration. None of the eggs in the OM group achieved the zero-second piercing time. Compared to the OM, the VM group showed a significantly shorter piercing time, 1.80 vs. 10.69 s on average, and a significantly better survival rate, 90.3 vs. 81.8% on average. VMS6_2 not only improved on the already demonstrated superiority of VM to OM but also enabled instantaneous piercing of the cell membrane.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
为受精卵细胞质显微注射中的瞬时细胞膜穿刺开发振动显微注射系统
为了尽快完成微注射,我们开发了振动微注射系统(VMSs),该系统使微管在纵向上振动,与普通(非振动)微注射相比,可以显着减少原核微注射所需的时间。最长的击穿时间是同时击穿细胞膜和原核膜所需的时间。由于细胞质微注射比原核微注射更加困难和耗时,因此我们下一步的目标是开发一种能够瞬间穿透细胞膜的VMS。在这个新的和最新的版本中,开发了两种类型的超声波振动器:第一种用于市售的微移液器(Femtotip),第二种用于自制的微移液器。这两个振动器的不同之处在于它们的密封结构,其中微移液管连接到各自的振动器:第一个振动器(VMS6_1)是一个内螺纹加o形环,第二个振动器(VMS6_2)是一个硅胶管。在VMS6_2中使用的管型接头对从振动器到微移管尖端的振动只有轻微的阻尼或放大,比在VMS6_1中使用的螺纹型接头更准确地传播振动。此外,VMS6_2显著缩短了受精卵穿透细胞膜的时间,平均为1.52 s (N = 410),而VMS6_1为3.62 s (N = 65)。VMS6_2组86.1%的卵子穿刺时间为零,而VMS6_1组只有10.8%的卵子穿刺时间为零。在每个振动器中,我们还比较了振动显微注射(VM;N = 475)和普通显微注射(OM;N = 457),用注射压力代替振动。OM组的卵子没有一个达到零秒的穿刺时间。与OM组相比,VM组穿刺时间明显缩短,平均为1.80 s比10.69 s,生存率明显提高,平均为90.3 s比81.8%。VMS6_2不仅改进了已经证明的VM相对于OM的优势,而且实现了瞬时穿膜。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Actuators
Actuators Mathematics-Control and Optimization
CiteScore
3.90
自引率
15.40%
发文量
315
审稿时长
11 weeks
期刊介绍: Actuators (ISSN 2076-0825; CODEN: ACTUC3) is an international open access journal on the science and technology of actuators and control systems published quarterly online by MDPI.
期刊最新文献
Current State, Needs, and Opportunities for Wearable Robots in Military Medical Rehabilitation and Force Protection. Numerical Investigation on the Evolution Process of Different Vortex Structures and Distributed Blowing Control for Dynamic Stall Suppression of Rotor Airfoils Experimental Research on Avoidance Obstacle Control for Mobile Robots Using Q-Learning (QL) and Deep Q-Learning (DQL) Algorithms in Dynamic Environments Design and Control of a Reconfigurable Robot with Rolling and Flying Locomotion Dynamic Path Planning for Mobile Robots by Integrating Improved Sparrow Search Algorithm and Dynamic Window Approach
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1