{"title":"Adjustable accuracy of phase steps in a double-aperture common-path interferometer by rotating and displacing grating at Fourier plane","authors":"Marymar Castillo-Luna, Cruz Meneses-Fabian","doi":"10.1088/2040-8986/ad0dee","DOIUrl":null,"url":null,"abstract":"Detuning errors limit the accuracy of phase extraction in phase-shifting interferometry (PSI). To improve this accuracy, the systems to control the phase shifter dispositive must be highly accurate, involving high technology, exhaustive calibration, high cost, and constant maintenance. This manuscript presents a method for improving the accuracy of the phase step generated at the Fourier plane by rotating and displacing the grating in a double-aperture common-path interferometer. It is demonstrated that both the detuning errors and the phase extraction uncertainty decrease with the grating rotation angle. The experimental implementation is very simple, as it does not require any sophisticated mechanical system to improve the accuracy, no exhaustive calibration, and no additional mechanical and optical dispositive. With the present approach, the PSI method could be achieved very simply and with high accuracy by using a low-accuracy actuator. The theoretical model and experimental results are presented to demonstrate the present proposal.","PeriodicalId":16775,"journal":{"name":"Journal of Optics","volume":"34 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2023-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Optics","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1088/2040-8986/ad0dee","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0
Abstract
Detuning errors limit the accuracy of phase extraction in phase-shifting interferometry (PSI). To improve this accuracy, the systems to control the phase shifter dispositive must be highly accurate, involving high technology, exhaustive calibration, high cost, and constant maintenance. This manuscript presents a method for improving the accuracy of the phase step generated at the Fourier plane by rotating and displacing the grating in a double-aperture common-path interferometer. It is demonstrated that both the detuning errors and the phase extraction uncertainty decrease with the grating rotation angle. The experimental implementation is very simple, as it does not require any sophisticated mechanical system to improve the accuracy, no exhaustive calibration, and no additional mechanical and optical dispositive. With the present approach, the PSI method could be achieved very simply and with high accuracy by using a low-accuracy actuator. The theoretical model and experimental results are presented to demonstrate the present proposal.
期刊介绍:
Journal of Optics publishes new experimental and theoretical research across all areas of pure and applied optics, both modern and classical. Research areas are categorised as:
Nanophotonics and plasmonics
Metamaterials and structured photonic materials
Quantum photonics
Biophotonics
Light-matter interactions
Nonlinear and ultrafast optics
Propagation, diffraction and scattering
Optical communication
Integrated optics
Photovoltaics and energy harvesting
We discourage incremental advances, purely numerical simulations without any validation, or research without a strong optics advance, e.g. computer algorithms applied to optical and imaging processes, equipment designs or material fabrication.