Peter Iversen, Stine Kramer, Andreas Ebbehoj, Esben Søndergaard, Kirstine Stochholm, Per Løgstrup Poulsen, Karin Hjorthaug
{"title":"[18F]FDOPA PET/CT is superior to [68Ga]DOTATOC PET/CT in diagnostic imaging of pheochromocytoma","authors":"Peter Iversen, Stine Kramer, Andreas Ebbehoj, Esben Søndergaard, Kirstine Stochholm, Per Løgstrup Poulsen, Karin Hjorthaug","doi":"10.1186/s13550-023-01056-4","DOIUrl":null,"url":null,"abstract":"Both [18F]FDOPA (FDOPA) and [68Ga]DOTATOC PET/CT (DOTATOC) are widely used for detection of pheochromocytomas/paraganglioma (PPGL). However, direct comparisons of the performance of the two tracers are only available in small series. We conducted a retrospective comparative analysis of FDOPA and DOTATOC to assess their sensitivity and accuracy in detecting PPGL when administered based on suspicion of PPGL. We consecutively included patients referred on suspicion of PPGL or PPGL recurrence who were scanned with both FDOPA and DOTATOC. Both scans were reviewed retrospectively by two experienced observers, who were blinded to the final diagnosis. The assessment was made both visually and quantitatively. The final diagnosis was primarily based on pathology. In total, 113 patients were included (97 suspected of primary PPGL and 16 suspected of recurrence). Of the 97 patients, 51 had pheochromocytomas (PCC) (in total 55 lesions) and 6 had paragangliomas (PGL) (in total 7 lesions). FDOPA detected and correctly localized all 55 PCC, while DOTATOC only detected 25 (sensitivity 100% vs. 49%, p < 0.0001; specificity 95% vs. 98%, p = 1.00). The negative predictive value (100% vs. 63%, p < 0.001) and diagnostic accuracy (98% vs. 70%, p < 0.01) were higher for FDOPA compared to DOTATOC. FDOPA identified 6 of 6 patients with hormone producing PGL, of which one was negative on DOTATOC. Diagnostic performances of FDOPA and DOTATOC were similar in the 16 patients with previous PPGL suspected of recurrence. FDOPA is superior to DOTATOC for localization of PCC. In contrast to DOTATOC, FDOPA also identified all PGL but with a limited number of patient cases.","PeriodicalId":11611,"journal":{"name":"EJNMMI Research","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2023-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13550-023-01056-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Both [18F]FDOPA (FDOPA) and [68Ga]DOTATOC PET/CT (DOTATOC) are widely used for detection of pheochromocytomas/paraganglioma (PPGL). However, direct comparisons of the performance of the two tracers are only available in small series. We conducted a retrospective comparative analysis of FDOPA and DOTATOC to assess their sensitivity and accuracy in detecting PPGL when administered based on suspicion of PPGL. We consecutively included patients referred on suspicion of PPGL or PPGL recurrence who were scanned with both FDOPA and DOTATOC. Both scans were reviewed retrospectively by two experienced observers, who were blinded to the final diagnosis. The assessment was made both visually and quantitatively. The final diagnosis was primarily based on pathology. In total, 113 patients were included (97 suspected of primary PPGL and 16 suspected of recurrence). Of the 97 patients, 51 had pheochromocytomas (PCC) (in total 55 lesions) and 6 had paragangliomas (PGL) (in total 7 lesions). FDOPA detected and correctly localized all 55 PCC, while DOTATOC only detected 25 (sensitivity 100% vs. 49%, p < 0.0001; specificity 95% vs. 98%, p = 1.00). The negative predictive value (100% vs. 63%, p < 0.001) and diagnostic accuracy (98% vs. 70%, p < 0.01) were higher for FDOPA compared to DOTATOC. FDOPA identified 6 of 6 patients with hormone producing PGL, of which one was negative on DOTATOC. Diagnostic performances of FDOPA and DOTATOC were similar in the 16 patients with previous PPGL suspected of recurrence. FDOPA is superior to DOTATOC for localization of PCC. In contrast to DOTATOC, FDOPA also identified all PGL but with a limited number of patient cases.
EJNMMI ResearchRADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING&nb-
CiteScore
5.90
自引率
3.10%
发文量
72
审稿时长
13 weeks
期刊介绍:
EJNMMI Research publishes new basic, translational and clinical research in the field of nuclear medicine and molecular imaging. Regular features include original research articles, rapid communication of preliminary data on innovative research, interesting case reports, editorials, and letters to the editor. Educational articles on basic sciences, fundamental aspects and controversy related to pre-clinical and clinical research or ethical aspects of research are also welcome. Timely reviews provide updates on current applications, issues in imaging research and translational aspects of nuclear medicine and molecular imaging technologies.
The main emphasis is placed on the development of targeted imaging with radiopharmaceuticals within the broader context of molecular probes to enhance understanding and characterisation of the complex biological processes underlying disease and to develop, test and guide new treatment modalities, including radionuclide therapy.