Laura Y Scholl, Emily L Hampp, Melanie Caba, Ali Azhar, Daniel Hameed, Jeremy Dubin, James P Crutcher, Michael A Mont, Ormonde M Mahoney
{"title":"Robotic-assisted Total Knee Arthroplasty Technology Provides a Repeatable and Reproducible Method of Assessing Soft Tissue Balance.","authors":"Laura Y Scholl, Emily L Hampp, Melanie Caba, Ali Azhar, Daniel Hameed, Jeremy Dubin, James P Crutcher, Michael A Mont, Ormonde M Mahoney","doi":"10.1055/a-2232-7511","DOIUrl":null,"url":null,"abstract":"<p><p>Soft-tissue balancing is an important factor in primary total knee arthroplasty (TKA), with 30 to 50% of TKA revisions attributed to technical operative factors including soft-tissue balancing. Robotic-assisted TKA (RATKA) offers opportunities for improved soft-tissue balancing methods. This study aimed to evaluate the repeatability and reproducibility of ligamentous laxity assessments during RATKA using a digital tensioner.Three experienced RATKA surgeons assessed preresection and trialing phases of 12 human cadaveric knees with varying degrees of arthritis. Ligamentous laxity was assessed with manual varus and valgus stresses in extension and flexion, with a digital tensioner providing feedback on the change of laxity displacement. Intraclass correlation coefficient (ICC) analyses were used to determine the repeatability within a single surgeon and reproducibility between the three surgeons.The results showed excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA. Surgeons had excellent repeatability for preresection and trialing assessments, with median ICC values representing excellent reproducibility between surgeons. Surgeons were repeatable within 1 or 1.5 mm for preresection and trialing assessments. On average, the variation within a surgeon was 0.33 ± 0.26 mm during preresection and 0.29 ± 0.28 mm during trialing. When comparing surgeons to each other, they were reproducible within an average of 0.69 ± 0.33 mm for preresection and 0.65 ± 0.31 mm for trialing.This study demonstrated the reliability of robotic-assisted soft-tissue balancing techniques, providing control over ligamentous laxity assessments, and potentially leading to better patient outcomes. The digital tensioner used in this study provided excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA, highlighting the potential benefits of incorporating robotics in TKA procedures.</p>","PeriodicalId":48798,"journal":{"name":"Journal of Knee Surgery","volume":" ","pages":"607-611"},"PeriodicalIF":1.6000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Knee Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2232-7511","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Soft-tissue balancing is an important factor in primary total knee arthroplasty (TKA), with 30 to 50% of TKA revisions attributed to technical operative factors including soft-tissue balancing. Robotic-assisted TKA (RATKA) offers opportunities for improved soft-tissue balancing methods. This study aimed to evaluate the repeatability and reproducibility of ligamentous laxity assessments during RATKA using a digital tensioner.Three experienced RATKA surgeons assessed preresection and trialing phases of 12 human cadaveric knees with varying degrees of arthritis. Ligamentous laxity was assessed with manual varus and valgus stresses in extension and flexion, with a digital tensioner providing feedback on the change of laxity displacement. Intraclass correlation coefficient (ICC) analyses were used to determine the repeatability within a single surgeon and reproducibility between the three surgeons.The results showed excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA. Surgeons had excellent repeatability for preresection and trialing assessments, with median ICC values representing excellent reproducibility between surgeons. Surgeons were repeatable within 1 or 1.5 mm for preresection and trialing assessments. On average, the variation within a surgeon was 0.33 ± 0.26 mm during preresection and 0.29 ± 0.28 mm during trialing. When comparing surgeons to each other, they were reproducible within an average of 0.69 ± 0.33 mm for preresection and 0.65 ± 0.31 mm for trialing.This study demonstrated the reliability of robotic-assisted soft-tissue balancing techniques, providing control over ligamentous laxity assessments, and potentially leading to better patient outcomes. The digital tensioner used in this study provided excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA, highlighting the potential benefits of incorporating robotics in TKA procedures.
期刊介绍:
The Journal of Knee Surgery covers a range of issues relating to the orthopaedic techniques of arthroscopy, arthroplasty, and reconstructive surgery of the knee joint. In addition to original peer-review articles, this periodical provides details on emerging surgical techniques, as well as reviews and special focus sections. Topics of interest include cruciate ligament repair and reconstruction, bone grafting, cartilage regeneration, and magnetic resonance imaging.