{"title":"Perioperative hemodynamic monitoring in cardiac surgery.","authors":"Michael C Grant, Rawn Salenger, Kevin W Lobdell","doi":"10.1097/ACO.0000000000001327","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>Cardiac surgery has traditionally relied upon invasive hemodynamic monitoring, including regular use of pulmonary artery catheters. More recently, there has been advancement in our understanding as well as broader adoption of less invasive alternatives. This review serves as an outline of the key perioperative hemodynamic monitoring options for cardiac surgery.</p><p><strong>Recent findings: </strong>Recent study has revealed that the use of invasive monitoring such as pulmonary artery catheters or transesophageal echocardiography in low-risk patients undergoing low-risk cardiac surgery is of questionable benefit. Lesser invasive approaches such a pulse contour analysis or ultrasound may provide a useful alternative to assess patient hemodynamics and guide resuscitation therapy. A number of recent studies have been published to support broader indication for these evolving technologies.</p><p><strong>Summary: </strong>More selective use of indwelling catheters for cardiac surgery has coincided with greater application of less invasive alternatives. Understanding the advantages and limitations of each tool allows the bedside clinician to identify which hemodynamic monitoring modality is most suitable for which patient.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ACO.0000000000001327","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/20 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose of review: Cardiac surgery has traditionally relied upon invasive hemodynamic monitoring, including regular use of pulmonary artery catheters. More recently, there has been advancement in our understanding as well as broader adoption of less invasive alternatives. This review serves as an outline of the key perioperative hemodynamic monitoring options for cardiac surgery.
Recent findings: Recent study has revealed that the use of invasive monitoring such as pulmonary artery catheters or transesophageal echocardiography in low-risk patients undergoing low-risk cardiac surgery is of questionable benefit. Lesser invasive approaches such a pulse contour analysis or ultrasound may provide a useful alternative to assess patient hemodynamics and guide resuscitation therapy. A number of recent studies have been published to support broader indication for these evolving technologies.
Summary: More selective use of indwelling catheters for cardiac surgery has coincided with greater application of less invasive alternatives. Understanding the advantages and limitations of each tool allows the bedside clinician to identify which hemodynamic monitoring modality is most suitable for which patient.