Ahmed Ehab, Axel T Kempa, Harald Englert, Shaza Almasri Bittar, Aida M Yousef, Heba Wagih Abdelwahab
{"title":"The Baveno Classification as a Predictor of CPAP Titration Pressure in Obstructive Sleep Apnea Syndrome.","authors":"Ahmed Ehab, Axel T Kempa, Harald Englert, Shaza Almasri Bittar, Aida M Yousef, Heba Wagih Abdelwahab","doi":"10.3390/arm91060042","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Obstructive sleep apnea syndrome (OSAS) is a clinical condition characterised by repeated periods of partial or full obstruction of airflow throughout sleep, with impairment of the quality of life and increased mortality with socioeconomic impacts. CPAP therapy is a simple and effective treatment option for OSAS patients. To overcome the clinical and prognostic limitations of AHI-as a sole index of OSAS-the Baveno classification was recently set out and introduced into clinical practice. This study aims to analyse the effect of the Baveno classification on the optimum CPAP titration pressure.</p><p><strong>Methods: </strong>A retrospective analysis of the records of sleep studies in two centres between 2018 and 2021 was carried out. Patients diagnosed with OSAS and recruited for CPAP titration were included. Based on the Baveno classification, the patients were categorised into four groups (A, B, C, and D).</p><p><strong>Results: </strong>Consequently, 700 patients were analysed and 427 patients were included. A significant positive correlation was detected between the CPAP optimum titration pressure and OSAS severity, neck circumference, the oxygen desaturation index (ODI), mean oxygen saturation, the AHI, the BMI, and cumulative sleep time when the SpO<sub>2</sub> was <90% (T90) on the other side (<i>p</i>: <0.0001). A non-significant correlation was seen between the Epworth Sleepiness Scale (ESS), symptom severity, end organ impact, and Baveno classification of the CPAP optimum titration pressure (<i>p</i>: 0.8, 0.4, 0.5, and 0.7, respectively).</p><p><strong>Conclusions: </strong>The Baveno classification is not useful in the prediction of CPAP optimum titration pressure. However, the ODI and neck circumference were significant independent predictors of a higher CPAP titration pressure.</p>","PeriodicalId":7391,"journal":{"name":"Advances in respiratory medicine","volume":"91 6","pages":"571-579"},"PeriodicalIF":1.8000,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10740694/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in respiratory medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/arm91060042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Obstructive sleep apnea syndrome (OSAS) is a clinical condition characterised by repeated periods of partial or full obstruction of airflow throughout sleep, with impairment of the quality of life and increased mortality with socioeconomic impacts. CPAP therapy is a simple and effective treatment option for OSAS patients. To overcome the clinical and prognostic limitations of AHI-as a sole index of OSAS-the Baveno classification was recently set out and introduced into clinical practice. This study aims to analyse the effect of the Baveno classification on the optimum CPAP titration pressure.
Methods: A retrospective analysis of the records of sleep studies in two centres between 2018 and 2021 was carried out. Patients diagnosed with OSAS and recruited for CPAP titration were included. Based on the Baveno classification, the patients were categorised into four groups (A, B, C, and D).
Results: Consequently, 700 patients were analysed and 427 patients were included. A significant positive correlation was detected between the CPAP optimum titration pressure and OSAS severity, neck circumference, the oxygen desaturation index (ODI), mean oxygen saturation, the AHI, the BMI, and cumulative sleep time when the SpO2 was <90% (T90) on the other side (p: <0.0001). A non-significant correlation was seen between the Epworth Sleepiness Scale (ESS), symptom severity, end organ impact, and Baveno classification of the CPAP optimum titration pressure (p: 0.8, 0.4, 0.5, and 0.7, respectively).
Conclusions: The Baveno classification is not useful in the prediction of CPAP optimum titration pressure. However, the ODI and neck circumference were significant independent predictors of a higher CPAP titration pressure.
期刊介绍:
"Advances in Respiratory Medicine" is a new international title for "Pneumonologia i Alergologia Polska", edited bimonthly and addressed to respiratory professionals. The Journal contains peer-reviewed original research papers, short communications, case-reports, recommendations of the Polish Respiratory Society concerning the diagnosis and treatment of lung diseases, editorials, postgraduate education articles, letters and book reviews in the field of pneumonology, allergology, oncology, immunology and infectious diseases. "Advances in Respiratory Medicine" is an open access, official journal of Polish Society of Lung Diseases, Polish Society of Allergology and National Research Institute of Tuberculosis and Lung Diseases.