Validity and Reliability of POM-Checker for Measuring Shoulder Range of Motion in Healthy Participants: A Pilot Single-Center Comparative Study.

IF 2 Q3 BIOCHEMICAL RESEARCH METHODS Methods and Protocols Pub Date : 2023-11-27 DOI:10.3390/mps6060114
Hongmin Chu, Weonjin Kim, Seongsu Joo, Eunsik Park, Yeong Won Kim, Cheol-Hyun Kim, Sangkwan Lee
{"title":"Validity and Reliability of POM-Checker for Measuring Shoulder Range of Motion in Healthy Participants: A Pilot Single-Center Comparative Study.","authors":"Hongmin Chu, Weonjin Kim, Seongsu Joo, Eunsik Park, Yeong Won Kim, Cheol-Hyun Kim, Sangkwan Lee","doi":"10.3390/mps6060114","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The aim of this study was to compare shoulder movement measurements between a Kinect-based markerless ROM assessment device (POM-Checker) and a 3D motion capture analysis system (BTS SMART DX-400).</p><p><strong>Methods: </strong>This was a single-visit clinical trial designed to evaluate the validity and reliability of the POM-Checker. The primary outcome was to assess the equivalence between two measurement devices within the same set of participants, aiming to evaluate the validity of the POM-Checker compared to the gold standard device (3D Motion Analysis System). As this was a pilot study, six participants were included.</p><p><strong>Results: </strong>The intraclass correlation coefficient (ICC) and the corresponding 95% confidence intervals (CIs) were used to assess the reproducibility of the measurements. Among the 18 movements analyzed, 16 exhibited ICC values of >0.75, indicating excellent reproducibility.</p><p><strong>Conclusion: </strong>The results showed that the POM-checker is reliable and validated to measure the range of motion of the shoulder joint.</p>","PeriodicalId":18715,"journal":{"name":"Methods and Protocols","volume":"6 6","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2023-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10745328/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Protocols","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/mps6060114","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The aim of this study was to compare shoulder movement measurements between a Kinect-based markerless ROM assessment device (POM-Checker) and a 3D motion capture analysis system (BTS SMART DX-400).

Methods: This was a single-visit clinical trial designed to evaluate the validity and reliability of the POM-Checker. The primary outcome was to assess the equivalence between two measurement devices within the same set of participants, aiming to evaluate the validity of the POM-Checker compared to the gold standard device (3D Motion Analysis System). As this was a pilot study, six participants were included.

Results: The intraclass correlation coefficient (ICC) and the corresponding 95% confidence intervals (CIs) were used to assess the reproducibility of the measurements. Among the 18 movements analyzed, 16 exhibited ICC values of >0.75, indicating excellent reproducibility.

Conclusion: The results showed that the POM-checker is reliable and validated to measure the range of motion of the shoulder joint.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
POM-Checker 用于测量健康参与者肩关节活动范围的有效性和可靠性:单中心试点对比研究
研究背景本研究旨在比较基于 Kinect 的无标记 ROM 评估设备(POM-Checker)和三维运动捕捉分析系统(BTS SMART DX-400)的肩关节运动测量结果:这是一项单次临床试验,旨在评估POM-Checker的有效性和可靠性。主要结果是评估在同一组参与者中两种测量设备之间的等效性,目的是评估 POM-Checker 与黄金标准设备(三维运动分析系统)相比的有效性。由于这是一项试验性研究,共有六名参与者参加:采用类内相关系数(ICC)和相应的 95% 置信区间(CI)来评估测量结果的可重复性。在分析的 18 个动作中,有 16 个动作的 ICC 值大于 0.75,表明重现性极佳:结果表明,POM-检查器在测量肩关节活动范围方面是可靠和有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Methods and Protocols
Methods and Protocols Biochemistry, Genetics and Molecular Biology-Biochemistry, Genetics and Molecular Biology (miscellaneous)
CiteScore
3.60
自引率
0.00%
发文量
85
审稿时长
8 weeks
期刊最新文献
A Streamlined In Vitro mRNA Production Evaluation for mRNA-Based Vaccines and Therapeutics. Does the Selected Segment Within a Two-Legged Hopping Trial Alter Leg Stiffness and Kinetic Performance Values and Their Variability? Study Protocol for Genomic Epidemiology Investigation of Intensive Care Unit Patient Colonization by Antimicrobial-Resistant ESKAPE Pathogens. New Approach for Targeting Small-Molecule Candidates for Intrinsically Disordered Proteins. Adaptation of the Motivational Interviewing Skills Code to Identify Client Language Predicting Reduced Opioid Use Risk and Increased Use of Alternative Pain Care Strategies in Veterans.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1