Achieving a Systolic Blood Pressure Below 130 mmHg Reduces the Incidence of Cardiovascular Events in Hypertensive Patients with Echocardiographic Left Ventricular Hypertrophy.
Maria Lembo, Valentina Trimarco, Raffaele Izzo, Maria Virginia Manzi, Francesco Rozza, Paola Gallo, Carmine Morisco, Luca Bardi, Giovanni Esposito, Imma Forzano, Gaetano Santulli, Bruno Trimarco
{"title":"Achieving a Systolic Blood Pressure Below 130 mmHg Reduces the Incidence of Cardiovascular Events in Hypertensive Patients with Echocardiographic Left Ventricular Hypertrophy.","authors":"Maria Lembo, Valentina Trimarco, Raffaele Izzo, Maria Virginia Manzi, Francesco Rozza, Paola Gallo, Carmine Morisco, Luca Bardi, Giovanni Esposito, Imma Forzano, Gaetano Santulli, Bruno Trimarco","doi":"10.1124/jpet.123.001952","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Recent reports have evidenced an increased mortality rate in hypertensive patients with electrocardiographic left ventricular hypertrophy (ECG-LVH) achieving systolic blood pressure (SBP) <130 mmHg. However, to the best of our knowledge, the actual effects of blood pressure reduction to the ≤130/80 mmHg target on the incidence of cardiovascular (CV) events have never been determined in hypertensive patients with a diagnosis of left ventricular hypertrophy based on echocardiographic criteria (Echo-LVH). <b>Methods:</b> To fill this long-standing knowledge gap, we harnessed a population of 9511 hypertensive patients, followed-up for 33.6 [interquartile range 7.9-72.7] months. The population was divided into six groups according to the average SBP achieved during the follow-up (≤130, 130-139, and ≥140 mmHg) and absence/presence of Echo-LVH. The primary endpoint was a composite of fatal or nonfatal myocardial infarction and stroke, sudden cardiac death, heart failure requiring hospitalization, revascularization, and carotid stenting. Secondary endpoints included atrial fibrillation and transient ischemic attack. <b>Results:</b> During the follow-up, achieved SBP and diastolic blood pressure (DBP) were comparable between patients with and without Echo-LVH. Strikingly, the rates of primary and secondary endpoints were significantly higher in patients with Echo-LVH and SBP >130 mmHg, reaching the highest values in the Echo-LVH group with SBP ≥140 mmHg. By separate Cox multivariable regressions, after adjusting for potential confounders, both primary and secondary endpoints were significantly associated with SBP ≥140 mmHg and Echo-LVH. Instead, DBP reduction ≤80 mmHg was associated with a significant increased rate of secondary events. <b>Conclusions:</b> In hypertensive patients with Echo-LVH, achieving an average in-treatment SBP target ≤130 mmHg has a beneficial prognostic impact on incidence of CV events. SIGNIFICANCE STATEMENT: Contrary to recent findings, achieving in-treatment SBP ≤130 mmHg lowers the incidence of CV events in hypertensive patients with Echo-LVH. However, reducing DBP ≤80 mmHg is linked to increased CV complications. Cox multivariable regression models, considering potential confounders, reveal that the rate of hard and soft CV events is significantly associated with Echo-LVH and SBP ≥140 mmHg. Our data indicate that therapeutic strategies for Echo-LVH patients should target SBP ≤130 mmHg while avoiding lowering DBP ≤80 mmHg.</p>","PeriodicalId":16798,"journal":{"name":"Journal of Pharmacology and Experimental Therapeutics","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11192578/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmacology and Experimental Therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1124/jpet.123.001952","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Recent reports have evidenced an increased mortality rate in hypertensive patients with electrocardiographic left ventricular hypertrophy (ECG-LVH) achieving systolic blood pressure (SBP) <130 mmHg. However, to the best of our knowledge, the actual effects of blood pressure reduction to the ≤130/80 mmHg target on the incidence of cardiovascular (CV) events have never been determined in hypertensive patients with a diagnosis of left ventricular hypertrophy based on echocardiographic criteria (Echo-LVH). Methods: To fill this long-standing knowledge gap, we harnessed a population of 9511 hypertensive patients, followed-up for 33.6 [interquartile range 7.9-72.7] months. The population was divided into six groups according to the average SBP achieved during the follow-up (≤130, 130-139, and ≥140 mmHg) and absence/presence of Echo-LVH. The primary endpoint was a composite of fatal or nonfatal myocardial infarction and stroke, sudden cardiac death, heart failure requiring hospitalization, revascularization, and carotid stenting. Secondary endpoints included atrial fibrillation and transient ischemic attack. Results: During the follow-up, achieved SBP and diastolic blood pressure (DBP) were comparable between patients with and without Echo-LVH. Strikingly, the rates of primary and secondary endpoints were significantly higher in patients with Echo-LVH and SBP >130 mmHg, reaching the highest values in the Echo-LVH group with SBP ≥140 mmHg. By separate Cox multivariable regressions, after adjusting for potential confounders, both primary and secondary endpoints were significantly associated with SBP ≥140 mmHg and Echo-LVH. Instead, DBP reduction ≤80 mmHg was associated with a significant increased rate of secondary events. Conclusions: In hypertensive patients with Echo-LVH, achieving an average in-treatment SBP target ≤130 mmHg has a beneficial prognostic impact on incidence of CV events. SIGNIFICANCE STATEMENT: Contrary to recent findings, achieving in-treatment SBP ≤130 mmHg lowers the incidence of CV events in hypertensive patients with Echo-LVH. However, reducing DBP ≤80 mmHg is linked to increased CV complications. Cox multivariable regression models, considering potential confounders, reveal that the rate of hard and soft CV events is significantly associated with Echo-LVH and SBP ≥140 mmHg. Our data indicate that therapeutic strategies for Echo-LVH patients should target SBP ≤130 mmHg while avoiding lowering DBP ≤80 mmHg.
期刊介绍:
A leading research journal in the field of pharmacology published since 1909, JPET provides broad coverage of all aspects of the interactions of chemicals with biological systems, including autonomic, behavioral, cardiovascular, cellular, clinical, developmental, gastrointestinal, immuno-, neuro-, pulmonary, and renal pharmacology, as well as analgesics, drug abuse, metabolism and disposition, chemotherapy, and toxicology.