Research on the variation of dielectric properties of oil-paper insulation for power equipment over a wide temperature range

IF 4.4 2区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC High Voltage Pub Date : 2023-12-20 DOI:10.1049/hve2.12397
Mingze Zhang, Muhe Yu, Wen Zhou, Yilin Liang, Shengjie Lei, Yunbo Shi, Limin Qu
{"title":"Research on the variation of dielectric properties of oil-paper insulation for power equipment over a wide temperature range","authors":"Mingze Zhang,&nbsp;Muhe Yu,&nbsp;Wen Zhou,&nbsp;Yilin Liang,&nbsp;Shengjie Lei,&nbsp;Yunbo Shi,&nbsp;Limin Qu","doi":"10.1049/hve2.12397","DOIUrl":null,"url":null,"abstract":"<p>The main part of oil-immersed power equipment is oil-paper insulation. At lower ambient temperatures, transformer oil will become viscous. As a result, compared to those at room temperature or operating temperature, the frequency domain dielectric properties of oil-paper insulation at low temperatures are drastically different. For evaluating the insulation condition of electrical equipment, it is essential to accurately determine their dielectric properties. This paper described the FDS test, the DC conductivity test, and the transformer oil viscosity test, which was carried out in a laboratory environment for different ageing of oil-immersed pressboard and transformer oil at 233–373 K. The effects of temperature on the dielectric properties at the competing mechanisms of polarisation and conductivity loss were clarified based on variations of the FDS curves. Considering the viscosity change of ageing transformer oil at low temperatures, the Arrhenius and VFT viscosity equations were used to achieve a fitting calculation in the different temperature zones. Based on the molecular/ion transition model in the force field and electric field, the characterisation relationships between the dynamic viscosity, DC conductivity, and test temperature of transformer oil were established. The limitations of conventional transformer oil equivalent dielectric relaxation models over a wide temperature range were finally clarified by combining the test findings of the DC conductivity over a wide temperature range with observed and simulated calculations. This paper provides an essential theoretical reference when using the FDS test to diagnose the insulation performance of oil-immersed power equipment in extremely cold regions.</p>","PeriodicalId":48649,"journal":{"name":"High Voltage","volume":"9 3","pages":"648-658"},"PeriodicalIF":4.4000,"publicationDate":"2023-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/hve2.12397","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"High Voltage","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/hve2.12397","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The main part of oil-immersed power equipment is oil-paper insulation. At lower ambient temperatures, transformer oil will become viscous. As a result, compared to those at room temperature or operating temperature, the frequency domain dielectric properties of oil-paper insulation at low temperatures are drastically different. For evaluating the insulation condition of electrical equipment, it is essential to accurately determine their dielectric properties. This paper described the FDS test, the DC conductivity test, and the transformer oil viscosity test, which was carried out in a laboratory environment for different ageing of oil-immersed pressboard and transformer oil at 233–373 K. The effects of temperature on the dielectric properties at the competing mechanisms of polarisation and conductivity loss were clarified based on variations of the FDS curves. Considering the viscosity change of ageing transformer oil at low temperatures, the Arrhenius and VFT viscosity equations were used to achieve a fitting calculation in the different temperature zones. Based on the molecular/ion transition model in the force field and electric field, the characterisation relationships between the dynamic viscosity, DC conductivity, and test temperature of transformer oil were established. The limitations of conventional transformer oil equivalent dielectric relaxation models over a wide temperature range were finally clarified by combining the test findings of the DC conductivity over a wide temperature range with observed and simulated calculations. This paper provides an essential theoretical reference when using the FDS test to diagnose the insulation performance of oil-immersed power equipment in extremely cold regions.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电力设备油纸绝缘介电性能在宽温度范围内的变化研究
油浸电力设备的主要部分是油纸绝缘。在较低的环境温度下,变压器油会变得粘稠。因此,与室温或工作温度下的绝缘相比,低温下油纸绝缘的频域介电性能大不相同。为了评估电气设备的绝缘状况,准确测定其介电特性至关重要。本文介绍了在实验室环境中对 233-373 K 下不同老化程度的油浸压纸板和变压器油进行的 FDS 测试、直流电导测试和变压器油粘度测试。考虑到老化变压器油在低温下的粘度变化,使用 Arrhenius 和 VFT 粘度方程对不同温度区进行了拟合计算。基于力场和电场中的分子/离子转变模型,建立了变压器油的动态粘度、直流电导和测试温度之间的表征关系。通过将宽温度范围内直流电导的测试结果与观测和模拟计算相结合,最终阐明了传统变压器油等效介电弛豫模型在宽温度范围内的局限性。本文为使用 FDS 测试诊断极寒地区油浸式电力设备的绝缘性能提供了重要的理论参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
High Voltage
High Voltage Energy-Energy Engineering and Power Technology
CiteScore
9.60
自引率
27.30%
发文量
97
审稿时长
21 weeks
期刊介绍: High Voltage aims to attract original research papers and review articles. The scope covers high-voltage power engineering and high voltage applications, including experimental, computational (including simulation and modelling) and theoretical studies, which include: Electrical Insulation ● Outdoor, indoor, solid, liquid and gas insulation ● Transient voltages and overvoltage protection ● Nano-dielectrics and new insulation materials ● Condition monitoring and maintenance Discharge and plasmas, pulsed power ● Electrical discharge, plasma generation and applications ● Interactions of plasma with surfaces ● Pulsed power science and technology High-field effects ● Computation, measurements of Intensive Electromagnetic Field ● Electromagnetic compatibility ● Biomedical effects ● Environmental effects and protection High Voltage Engineering ● Design problems, testing and measuring techniques ● Equipment development and asset management ● Smart Grid, live line working ● AC/DC power electronics ● UHV power transmission Special Issues. Call for papers: Interface Charging Phenomena for Dielectric Materials - https://digital-library.theiet.org/files/HVE_CFP_ICP.pdf Emerging Materials For High Voltage Applications - https://digital-library.theiet.org/files/HVE_CFP_EMHVA.pdf
期刊最新文献
Research on temperature distribution characteristics of oil-immersed power transformers based on fluid network decoupling On image transformation for partial discharge source identification in vehicle cable terminals of high-speed trains New insights on thermal ageing of electrical insulating oils as revealed from photoluminescence and absorption spectroscopy Energy regulation of impulse current generator modulated DC arc discharge Stress grading system optimisation for an inverter-fed rotating machine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1