Use of a Fatty Meal Cholecystagogue Protocol in Hepatobiliary Scintigraphy for Chronic Functional Gallbladder Disease

IF 1 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of nuclear medicine technology Pub Date : 2023-12-13 DOI:10.2967/jnmt.123.266789
Justin G. Peacock, Horace A. Hayes, Tylor D. Connor
{"title":"Use of a Fatty Meal Cholecystagogue Protocol in Hepatobiliary Scintigraphy for Chronic Functional Gallbladder Disease","authors":"Justin G. Peacock, Horace A. Hayes, Tylor D. Connor","doi":"10.2967/jnmt.123.266789","DOIUrl":null,"url":null,"abstract":"Chronic functional gallbladder disorder, characterized by biliary pain in the absence of structural pathology, poses a diagnostic challenge necessitating reliable cholecystagogues for accurate evaluation. However, recurrent shortages of synthetic cholecystokinin analogs have prompted the exploration of alternative agents. This paper describes the ef fi cacy of Ensure Plus as a viable fatty meal substitute for hepatobiliary scintigraphy in assessing chronic functional gall-bladder disorder. Through comparative studies, Ensure Plus demonstrates comparable diagnostic accuracy to cholecystokinin in similar patient populations. Furthermore, Ensure Plus demonstrates signi fi - cant symptom improvement after cholecystectomy in patients with anomalous gallbladder ejection fractions. This paper offers a detailed protocol for the seamless integration of Ensure Plus into hepatobiliary scintigraphy, providing clinicians with a valuable tool to navigate cholecystokinin shortages while maintaining diagnostic precision in cases of chronic functional gallbladder disorder. The use of Ensure Plus not only addresses practical supply challenges but also underscores its potential as a cost-effective and clinically sound alternative in biliary diagnostics.","PeriodicalId":16548,"journal":{"name":"Journal of nuclear medicine technology","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2023-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nuclear medicine technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2967/jnmt.123.266789","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Chronic functional gallbladder disorder, characterized by biliary pain in the absence of structural pathology, poses a diagnostic challenge necessitating reliable cholecystagogues for accurate evaluation. However, recurrent shortages of synthetic cholecystokinin analogs have prompted the exploration of alternative agents. This paper describes the ef fi cacy of Ensure Plus as a viable fatty meal substitute for hepatobiliary scintigraphy in assessing chronic functional gall-bladder disorder. Through comparative studies, Ensure Plus demonstrates comparable diagnostic accuracy to cholecystokinin in similar patient populations. Furthermore, Ensure Plus demonstrates signi fi - cant symptom improvement after cholecystectomy in patients with anomalous gallbladder ejection fractions. This paper offers a detailed protocol for the seamless integration of Ensure Plus into hepatobiliary scintigraphy, providing clinicians with a valuable tool to navigate cholecystokinin shortages while maintaining diagnostic precision in cases of chronic functional gallbladder disorder. The use of Ensure Plus not only addresses practical supply challenges but also underscores its potential as a cost-effective and clinically sound alternative in biliary diagnostics.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在慢性功能性胆囊疾病的肝胆闪烁扫描中使用脂肪餐胆囊收缩剂方案
慢性功能性胆囊疾病的特点是在没有结构性病变的情况下出现胆道疼痛,这给诊断带来了挑战,需要可靠的胆囊刺激剂来进行准确评估。然而,合成胆囊收缩素类似物的经常性短缺促使人们开始探索替代药物。本文介绍了 Ensure Plus 作为肝胆闪烁成像的可行脂肪餐替代品在评估慢性功能性胆囊疾病方面的有效性。通过比较研究,在类似的患者群体中,安素可显示出与胆囊收缩素相当的诊断准确性。此外,Ensure Plus 还能显著改善胆囊射血分数异常患者胆囊切除术后的症状。本文提供了将 Ensure Plus 无缝整合到肝胆闪烁扫描中的详细方案,为临床医生提供了一种宝贵的工具,可用于解决胆囊收缩素短缺问题,同时保持慢性功能性胆囊疾病诊断的精确性。Ensure Plus 的使用不仅解决了供应方面的实际挑战,还凸显了其作为胆道诊断中一种经济、临床合理的替代品的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of nuclear medicine technology
Journal of nuclear medicine technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.90
自引率
15.40%
发文量
57
期刊最新文献
Comment Regarding "Vapocoolant Analgesia for Breast Lymphoscintigraphy: A Prospective Clinical Trial". Navigating a Transatlantic Career Shift: Guidance for U.S. Nuclear Medicine Technologists Looking to Relocate to the U.K. So You Are a Clinical Instructor-Now What? The Effect of Monitored Walking on Extracardiac Intestinal Activity in Myocardial Perfusion Imaging. A Multiradionuclide Automatic Dispensing System for Syringes of Radiopharmaceuticals: The Effect on Operator Hand Dose.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1