The Intra-Rater Reliability of Ultrasonography for the Measurement of Lumbar Multifidus and Erector Spinae Thickness in Different Positions in People with and without Active Extension-Related Non-Specific Low Back Pain.

Q2 Medicine Medical Journal of the Islamic Republic of Iran Pub Date : 2023-10-03 eCollection Date: 2023-01-01 DOI:10.47176/mjiri.37.107
Gitta Kalbassi, Nader Maroufi, Ismail Ebrahimi Takamjani, Mahyar Salavati, Asghar Rezasoltani, Saeed Talebian, Sara Salamat, Kieran O'Sullivan
{"title":"The Intra-Rater Reliability of Ultrasonography for the Measurement of Lumbar Multifidus and Erector Spinae Thickness in Different Positions in People with and without Active Extension-Related Non-Specific Low Back Pain.","authors":"Gitta Kalbassi, Nader Maroufi, Ismail Ebrahimi Takamjani, Mahyar Salavati, Asghar Rezasoltani, Saeed Talebian, Sara Salamat, Kieran O'Sullivan","doi":"10.47176/mjiri.37.107","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The paraspinal muscles, including multifidus (MF) and erector spinae (ES) play key roles in the stability and movement of the lumbar spine. This study aimed to determine the intra-rater reliability of the ES and MF muscle thickness measures of the rehabilitative ultrasound imaging (RUSI) in people with active extension pattern (AEP) non-specific chronic low back pain and controls.</p><p><strong>Methods: </strong>Fifteen females with AEP and 19 controls participated in this test-retest intra-rater reliability study, including two different testing sessions performed in four to seven days apart. The primary (raw) and derived (normalized) measures of the L4 MF and ES muscles`thickness were examined in three different positions (prone, sitting, and standing) on both days. A two-way mixed average of intra-class correlation coefficient (ICC3, K) with confidence interval (CI = 95%) was used to determine the relative reliability. The standard error of measurement (SEM) and minimal detectable change (MDC) values at a CI of 95% were computed to examine the absolute reliability.</p><p><strong>Results: </strong>The ICC values for the primary thickness of the L4 ES and MF muscles were from 0.85 to 0.91, except for MF muscle thickness in standing (ICC = 0.67) and sitting (ICC = 0.66) positions . The ICC values for derived data were lower in both groups. The SEM and MDC values were small enough to confirm the absolute reliability of the primary data.</p><p><strong>Conclusion: </strong>This study supports the use of RUSI for examining the primary measures of the L4 MF and ES muscles in asymptomatic and AEP participants, but it should be used cautiously for assessing the derived measures.</p>","PeriodicalId":18361,"journal":{"name":"Medical Journal of the Islamic Republic of Iran","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10744124/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Journal of the Islamic Republic of Iran","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47176/mjiri.37.107","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The paraspinal muscles, including multifidus (MF) and erector spinae (ES) play key roles in the stability and movement of the lumbar spine. This study aimed to determine the intra-rater reliability of the ES and MF muscle thickness measures of the rehabilitative ultrasound imaging (RUSI) in people with active extension pattern (AEP) non-specific chronic low back pain and controls.

Methods: Fifteen females with AEP and 19 controls participated in this test-retest intra-rater reliability study, including two different testing sessions performed in four to seven days apart. The primary (raw) and derived (normalized) measures of the L4 MF and ES muscles`thickness were examined in three different positions (prone, sitting, and standing) on both days. A two-way mixed average of intra-class correlation coefficient (ICC3, K) with confidence interval (CI = 95%) was used to determine the relative reliability. The standard error of measurement (SEM) and minimal detectable change (MDC) values at a CI of 95% were computed to examine the absolute reliability.

Results: The ICC values for the primary thickness of the L4 ES and MF muscles were from 0.85 to 0.91, except for MF muscle thickness in standing (ICC = 0.67) and sitting (ICC = 0.66) positions . The ICC values for derived data were lower in both groups. The SEM and MDC values were small enough to confirm the absolute reliability of the primary data.

Conclusion: This study supports the use of RUSI for examining the primary measures of the L4 MF and ES muscles in asymptomatic and AEP participants, but it should be used cautiously for assessing the derived measures.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在有和没有主动伸展相关非特异性腰痛的人群中,不同体位下测量腰部多裂肌和脊肌厚度的超声波检查的内部评分者可靠性。
背景:脊柱旁肌肉,包括多裂肌(MF)和竖脊肌(ES)在腰椎的稳定性和活动中起着关键作用。本研究旨在确定康复超声成像(RUSI)测量非特异性慢性腰痛患者和对照组 ES 和 MF 肌肉厚度的评分内可靠性:方法:15 名 AEP 女性患者和 19 名对照组患者参加了此次测试-重测内部评分可靠性研究,包括两次不同的测试,每次测试间隔 4 到 7 天。在这两天中,以三种不同的姿势(俯卧、坐姿和站姿)对 L4 MF 和 ES 肌肉厚度进行了主要(原始)和衍生(归一化)测量。采用带置信区间(CI = 95%)的双向混合平均类内相关系数(ICC3,K)来确定相对可靠性。计算测量标准误差(SEM)和置信区间为 95% 的最小可检测变化(MDC)值,以检查绝对可靠性:除了站姿(ICC = 0.67)和坐姿(ICC = 0.66)下的中频肌肉厚度外,L4 ES 和中频肌肉原始厚度的 ICC 值为 0.85 至 0.91。两组衍生数据的 ICC 值均较低。SEM 和 MDC 值较小,足以确认主要数据的绝对可靠性:本研究支持使用 RUSI 检查无症状和 AEP 参与者 L4 MF 和 ES 肌肉的主要测量数据,但应谨慎使用 RUSI 评估衍生测量数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.40
自引率
0.00%
发文量
90
审稿时长
8 weeks
期刊最新文献
A 12-year Life History of a Girl with Profound Intellectual Disability and Leukoencephalopathy: A Rare Clinical Presentation of X Chromosome Pentasomy. A Three-Year Investigation on Corpses Referred to Legal Medicine Organization from An Iranian General Hospital: A Cross-Sectional Study. A Single-Subject Study to Consider the Premature Infant Oral Motor Intervention Combined with Kinesio-Tape in Premature Infants with Feeding Problems. The Factor Structure and Generalizability of the Iranian Socioeconomic Status (SES) Questionnaire Administered in a Nationally Divergent Population. Serum Vitamin D and Zinc Levels in Children with Urinary Tract Infection without Confounding Factors: A Case-Control Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1