Transformer-based 2D/3D medical image registration for X-ray to CT via anatomical features

Feng Qu, Min Zhang, Weili Shi, Wei He, Zhengang Jiang
{"title":"Transformer-based 2D/3D medical image registration for X-ray to CT via anatomical features","authors":"Feng Qu,&nbsp;Min Zhang,&nbsp;Weili Shi,&nbsp;Wei He,&nbsp;Zhengang Jiang","doi":"10.1002/rcs.2619","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>2D/3D medical image registration is one of the key technologies for surgical navigation systems to perform pose estimation and achieve accurate positioning, which still remains challenging. The purpose of this study is to introduce a new method for X-ray to CT 2D/3D registration and conduct a feasibility study.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>In this study, a 2D/3D affine registration method based on feature point detection is investigated. It combines the morphological and edge features of spinal images to accurately extract feature points from the images, and uses graph neural networks to aggregate anatomical features of different points to increase the local detail information. Meanwhile, global and positional information are extracted by the Swin Transformer.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The results indicate that the proposed method has shown improvements in both accuracy and success ratio compared with other methods. The mean target registration error value reached up to 0.31 mm; meanwhile, the runtime overhead was much lower, achieving an average runtime of about 0.6 s. This ultimately improves the registration accuracy and efficiency, demonstrating the effectiveness of the proposed method.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The proposed method can provide more comprehensive image information and shows good prospects for pose estimation and achieving accurate positioning in surgical navigation systems.</p>\n </section>\n </div>","PeriodicalId":50311,"journal":{"name":"International Journal of Medical Robotics and Computer Assisted Surgery","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2023-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Robotics and Computer Assisted Surgery","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcs.2619","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background

2D/3D medical image registration is one of the key technologies for surgical navigation systems to perform pose estimation and achieve accurate positioning, which still remains challenging. The purpose of this study is to introduce a new method for X-ray to CT 2D/3D registration and conduct a feasibility study.

Methods

In this study, a 2D/3D affine registration method based on feature point detection is investigated. It combines the morphological and edge features of spinal images to accurately extract feature points from the images, and uses graph neural networks to aggregate anatomical features of different points to increase the local detail information. Meanwhile, global and positional information are extracted by the Swin Transformer.

Results

The results indicate that the proposed method has shown improvements in both accuracy and success ratio compared with other methods. The mean target registration error value reached up to 0.31 mm; meanwhile, the runtime overhead was much lower, achieving an average runtime of about 0.6 s. This ultimately improves the registration accuracy and efficiency, demonstrating the effectiveness of the proposed method.

Conclusions

The proposed method can provide more comprehensive image information and shows good prospects for pose estimation and achieving accurate positioning in surgical navigation systems.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于变压器的二维/三维医学图像配准,通过解剖学特征将 X 光片配准到 CT
二维/三维医学影像配准是手术导航系统进行姿态估计和实现精确定位的关键技术之一,但这一技术仍具有挑战性。本研究旨在介绍一种新的 X 射线到 CT 2D/3D 配准方法,并进行可行性研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.50
自引率
12.00%
发文量
131
审稿时长
6-12 weeks
期刊介绍: The International Journal of Medical Robotics and Computer Assisted Surgery provides a cross-disciplinary platform for presenting the latest developments in robotics and computer assisted technologies for medical applications. The journal publishes cutting-edge papers and expert reviews, complemented by commentaries, correspondence and conference highlights that stimulate discussion and exchange of ideas. Areas of interest include robotic surgery aids and systems, operative planning tools, medical imaging and visualisation, simulation and navigation, virtual reality, intuitive command and control systems, haptics and sensor technologies. In addition to research and surgical planning studies, the journal welcomes papers detailing clinical trials and applications of computer-assisted workflows and robotic systems in neurosurgery, urology, paediatric, orthopaedic, craniofacial, cardiovascular, thoraco-abdominal, musculoskeletal and visceral surgery. Articles providing critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies, commenting on ease of use, or addressing surgical education and training issues are also encouraged. The journal aims to foster a community that encompasses medical practitioners, researchers, and engineers and computer scientists developing robotic systems and computational tools in academic and commercial environments, with the intention of promoting and developing these exciting areas of medical technology.
期刊最新文献
Robotic Left Hepatectomy Using the Glissonean Approach and Saline-Linked Bipolar Clamp-Crush Technique This is the first in-human trial and prospective case series of a novel single-port robotic system for gynaecological surgery: An IDEAL stage 2a study Initial Experience of Robot Assisted Laparoscopic Pyeloplasty for Ureteropelvic Junction Obstruction Using the Hinotori Surgical Robot System Design and Modelling of Continuum Robot for Endoscopic Submucosal Dissection Surgery With Lifting Force Estimation Robot-Assisted Ocular Tumour Radiotherapy Positioning and Tracking System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1