Jiale He, Yunxiang Lu, Yuxian Chen, You Peng, Qi Zhu, Zhiyong Li
{"title":"Deep Circumflex Iliac Artery-vascularized Iliac Bone Graft for Femoral Head Osteonecrosis: Computed Tomography Anatomical Study.","authors":"Jiale He, Yunxiang Lu, Yuxian Chen, You Peng, Qi Zhu, Zhiyong Li","doi":"10.1055/a-2238-7798","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong> Deep circumflex iliac artery (DCIA)-vascularized iliac graft transposition is a method for treating femoral head osteonecrosis but with inconsistent efficacy. We aim to improve the method of this surgery by recommending the optimal location of the iliac pedicle to satisfy the vascular length for transposition and the blood supply of the vascularized iliac graft.</p><p><strong>Methods: </strong> The DCIA and its surrounding tissues were assessed on computed tomography angiography images for 100 sides (left and right) of 50 patients. The length of the vascular pedicle required for transposition and the length of the pedicle at different iliac spine positions were compared. The diameter and cross-sectional area of the DCIA and the distance between the DCIA and iliac spine were measured at different points to assess blood supply. We also compared differences in sex and left-right position.</p><p><strong>Results: </strong> The diameter and cross-sectional area of the DCIA gradually decreased after crossing the anterior superior iliac spine (ASIS), and it approached the iliac bone. However, when the DCIA was 4 cm behind the ASIS (54 sides, 54%), it coursed posteriorly and superiorly away from the iliac spine. The vascular length of the pedicle was insufficient to transpose the vascularized iliac graft to the desired position when it was within 1 cm of the ASIS. The vascular length requirement was satisfied, and the blood supply was sufficient when the pedicle was positioned at 2 or 3 cm.</p><p><strong>Conclusion: </strong> To obtain a satisfactory pedicle length and sufficient blood supply, the DCIA pedicle of the vascularized iliac graft should be placed 2 to 3 cm behind the ASIS. The dissection of DCIA has slight differences in sex and left-right position due to anatomical differences.</p>","PeriodicalId":16949,"journal":{"name":"Journal of reconstructive microsurgery","volume":" ","pages":"496-503"},"PeriodicalIF":2.2000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11309803/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of reconstructive microsurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2238-7798","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Deep circumflex iliac artery (DCIA)-vascularized iliac graft transposition is a method for treating femoral head osteonecrosis but with inconsistent efficacy. We aim to improve the method of this surgery by recommending the optimal location of the iliac pedicle to satisfy the vascular length for transposition and the blood supply of the vascularized iliac graft.
Methods: The DCIA and its surrounding tissues were assessed on computed tomography angiography images for 100 sides (left and right) of 50 patients. The length of the vascular pedicle required for transposition and the length of the pedicle at different iliac spine positions were compared. The diameter and cross-sectional area of the DCIA and the distance between the DCIA and iliac spine were measured at different points to assess blood supply. We also compared differences in sex and left-right position.
Results: The diameter and cross-sectional area of the DCIA gradually decreased after crossing the anterior superior iliac spine (ASIS), and it approached the iliac bone. However, when the DCIA was 4 cm behind the ASIS (54 sides, 54%), it coursed posteriorly and superiorly away from the iliac spine. The vascular length of the pedicle was insufficient to transpose the vascularized iliac graft to the desired position when it was within 1 cm of the ASIS. The vascular length requirement was satisfied, and the blood supply was sufficient when the pedicle was positioned at 2 or 3 cm.
Conclusion: To obtain a satisfactory pedicle length and sufficient blood supply, the DCIA pedicle of the vascularized iliac graft should be placed 2 to 3 cm behind the ASIS. The dissection of DCIA has slight differences in sex and left-right position due to anatomical differences.
期刊介绍:
The Journal of Reconstructive Microsurgery is a peer-reviewed, indexed journal that provides an international forum for the publication of articles focusing on reconstructive microsurgery and complex reconstructive surgery. The journal was originally established in 1984 for the microsurgical community to publish and share academic papers.
The Journal of Reconstructive Microsurgery provides the latest in original research spanning basic laboratory, translational, and clinical investigations. Review papers cover current topics in complex reconstruction and microsurgery. In addition, special sections discuss new technologies, innovations, materials, and significant problem cases.
The journal welcomes controversial topics, editorial comments, book reviews, and letters to the Editor, in order to complete the balanced spectrum of information available in the Journal of Reconstructive Microsurgery. All articles undergo stringent peer review by international experts in the specialty.