Yeşim Deniz, Hakan Eren, Rüya Sessiz, Gamze Coşan Ata
{"title":"Comparison of CBCT radiation doses with conventional radiographs in TMJ imaging using Monte Carlo simulations.","authors":"Yeşim Deniz, Hakan Eren, Rüya Sessiz, Gamze Coşan Ata","doi":"10.1007/s00411-023-01057-w","DOIUrl":null,"url":null,"abstract":"<p><p>Three-dimensional imaging methods are widely used for evaluation of bony changes of temporomandibular joint (TMJ). Besides, lateral and posterio-anterior TMJ projections in both closed- and open-jaw positions for each temporomandibular joint are used as two-dimensional diagnostic tools. The purpose of the present study was to compare effective and mean organ absorbed doses of plain radiography techniques with those of different modalities of cone beam computed tomography (CBCT) scanning of an adult's temporomandibular joint. PCXMC 2.0 software was used to calculate mean organ and effective doses. A NewTom CBCT device (Newtom 5G XL; QR systems; Verona, Italy) was simulated at 360° rotation using a 6 × 6 cm<sup>2</sup> FOV in standard and high-resolution modes. Lateral and posterio-anterior TMJ plain projections were simulated according to recommendations of the manufacturer of the Planmeca ProMax<sup>®</sup> 2D S3 device. Doses for both projections were simulated with Monte Carlo methods and the International Commission on radiological protection adult reference computational phantoms. The highest mean organ absorbed doses occurred in bone surfaces, salivary glands, and skull for posterio-anterior TMJ and lateral TMJ, and for CBCT scanning in all examinations. The effective doses of posterio-anterior and lateral TMJ plain radiographs were found to be higher than those of the Standard Mode-Eco Scan CBCT. Therefore, the lowest effective dose was calculated in Standard Mode-Eco Scan CBCT. It is concluded that NewTom 5G XL Standard Mode-Eco Scan CBCT can be used instead of plain radiographs (lateral and posterio-anterior TMJ) in temporomandibular joint imaging as it allows visualizing the three-dimensional structure of the temporomandibular joint as an advantage.</p>","PeriodicalId":21002,"journal":{"name":"Radiation and Environmental Biophysics","volume":" ","pages":"39-45"},"PeriodicalIF":1.5000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation and Environmental Biophysics","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1007/s00411-023-01057-w","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Three-dimensional imaging methods are widely used for evaluation of bony changes of temporomandibular joint (TMJ). Besides, lateral and posterio-anterior TMJ projections in both closed- and open-jaw positions for each temporomandibular joint are used as two-dimensional diagnostic tools. The purpose of the present study was to compare effective and mean organ absorbed doses of plain radiography techniques with those of different modalities of cone beam computed tomography (CBCT) scanning of an adult's temporomandibular joint. PCXMC 2.0 software was used to calculate mean organ and effective doses. A NewTom CBCT device (Newtom 5G XL; QR systems; Verona, Italy) was simulated at 360° rotation using a 6 × 6 cm2 FOV in standard and high-resolution modes. Lateral and posterio-anterior TMJ plain projections were simulated according to recommendations of the manufacturer of the Planmeca ProMax® 2D S3 device. Doses for both projections were simulated with Monte Carlo methods and the International Commission on radiological protection adult reference computational phantoms. The highest mean organ absorbed doses occurred in bone surfaces, salivary glands, and skull for posterio-anterior TMJ and lateral TMJ, and for CBCT scanning in all examinations. The effective doses of posterio-anterior and lateral TMJ plain radiographs were found to be higher than those of the Standard Mode-Eco Scan CBCT. Therefore, the lowest effective dose was calculated in Standard Mode-Eco Scan CBCT. It is concluded that NewTom 5G XL Standard Mode-Eco Scan CBCT can be used instead of plain radiographs (lateral and posterio-anterior TMJ) in temporomandibular joint imaging as it allows visualizing the three-dimensional structure of the temporomandibular joint as an advantage.
期刊介绍:
This journal is devoted to fundamental and applied issues in radiation research and biophysics. The topics may include:
Biophysics of ionizing radiation: radiation physics and chemistry, radiation dosimetry, radiobiology, radioecology, biophysical foundations of medical applications of radiation, and radiation protection.
Biological effects of radiation: experimental or theoretical work on molecular or cellular effects; relevance of biological effects for risk assessment; biological effects of medical applications of radiation; relevance of radiation for biosphere and in space; modelling of ecosystems; modelling of transport processes of substances in biotic systems.
Risk assessment: epidemiological studies of cancer and non-cancer effects; quantification of risk including exposures to radiation and confounding factors
Contributions to these topics may include theoretical-mathematical and experimental material, as well as description of new techniques relevant for the study of these issues. They can range from complex radiobiological phenomena to issues in health physics and environmental protection.