A CVT-based Variable Stiffness Actuator for pHRI: Design Optimization and Performance Verification

Emir Mobedi, M. Dede
{"title":"A CVT-based Variable Stiffness Actuator for pHRI: Design Optimization and Performance Verification","authors":"Emir Mobedi, M. Dede","doi":"10.1115/1.4064280","DOIUrl":null,"url":null,"abstract":"Physical human-robot interfaces (pHRI) enabled the robots to work alongside the human workers complying with the regulations set for physical human-robot interaction systems. A variety of actuation systems named variable stiffness/impedance actuators (VSAs) are configured to be used in these systems' design. Recently, we introduced a new continuously variable transmission (CVT) mechanism as an alternative solution in configuring VSAs for pHRI. The optimization of this CVT has significant importance to enhance its application area and to detect the limitations of the system. Thus, in this paper, we present a design optimization approach (an adjustment strategy) for this system based on the design goals, desired force and minimization of the size of the system. To implement such design goals, the static force analysis of the CVT is performed and validated. Furthermore, the fabrication of the optimized prototype is presented, and the experimental verification is performed considering the requirements of VSAs: independent position and stiffness variation, and shock absorbing. Finally, the system is calibrated to display 6 N continuous output force throughout its transmission variation range.","PeriodicalId":508172,"journal":{"name":"Journal of Mechanisms and Robotics","volume":"43 15","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mechanisms and Robotics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4064280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Physical human-robot interfaces (pHRI) enabled the robots to work alongside the human workers complying with the regulations set for physical human-robot interaction systems. A variety of actuation systems named variable stiffness/impedance actuators (VSAs) are configured to be used in these systems' design. Recently, we introduced a new continuously variable transmission (CVT) mechanism as an alternative solution in configuring VSAs for pHRI. The optimization of this CVT has significant importance to enhance its application area and to detect the limitations of the system. Thus, in this paper, we present a design optimization approach (an adjustment strategy) for this system based on the design goals, desired force and minimization of the size of the system. To implement such design goals, the static force analysis of the CVT is performed and validated. Furthermore, the fabrication of the optimized prototype is presented, and the experimental verification is performed considering the requirements of VSAs: independent position and stiffness variation, and shock absorbing. Finally, the system is calibrated to display 6 N continuous output force throughout its transmission variation range.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于无级变速器的 pHRI 可变刚度致动器:设计优化与性能验证
物理人机界面(pHRI)使机器人能够与人类工人一起工作,符合物理人机交互系统的规定。在这些系统的设计中,配置了各种名为可变刚度/阻抗致动器(VSA)的执行系统。最近,我们引入了一种新的无级变速器(CVT)机制,作为为 pHRI 配置 VSA 的替代解决方案。对这种无级变速器进行优化对提高其应用范围和检测系统的局限性具有重要意义。因此,在本文中,我们根据设计目标、所需的力和最小化系统尺寸,为该系统提出了一种设计优化方法(调整策略)。为了实现这些设计目标,我们对无级变速器进行了静态力分析并进行了验证。此外,还介绍了优化原型的制造过程,并根据 VSA 的要求进行了实验验证:独立的位置和刚度变化以及减震。最后,对系统进行了校准,使其在整个传动变化范围内显示 6 N 的连续输出力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development and Analysis of a Novel Bio-syncretic Parallel Hip Exoskeleton Based on Torque Requirements A Novel Head-following Algorithm for Multi-Joint Articulated Driven Continuum Robots Development of a 6 degrees- of-freedom hybrid interface intended for teleoperated robotic cervical spine surgery Improving Terrain Adaptability and Compliance in Closed-Chain Leg: Design, Control, and Testing Errata: Static Stability of Planar Contacting Systems: Analytical Treatment in Euclidean Space. ASME J. Mech. Rob., 16(8): p. 081009; DOI:10.1115/1.4064065
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1