Antonio Leccisotti, Stefania V. Fields, G. De Bartolo, Christian Crudale
{"title":"Effective optical zone after corneal lenticule extraction with the CLEAR femtosecond laser application","authors":"Antonio Leccisotti, Stefania V. Fields, G. De Bartolo, Christian Crudale","doi":"10.4081/ltj.2023.326","DOIUrl":null,"url":null,"abstract":"Laser vision correction of myopia induces an effective optical zone (EOZ) smaller than the programmed optical zone (POZ) by 16 to 26%. We evaluated the EOZ after corneal lenticule extraction for myopia with astigmatism ≤1 diopter (D) with a new femtosecond laser application (CLEAR), compared to POZ in a retrospective, consecutive, comparative case series study. Forty eyes of 40 patients underwent lenticule extraction with the Ziemer CLEAR® application; the control group was composed of 40 eyes of 40 patients receiving myopic femtosecond laser in situ keratomileusis (LASIK); EOZ was calculated on difference tangential maps at 6 months. For lenticule extraction, mean preoperative spherical equivalent (SE) was -6.03±2.48 D; mean POZ was 6.43±0.27 mm; EOZ 5.55±0.45 mm; mean difference between POZ and EOZ was 0.88 ± 0.28 mm (p=0.00); the mean reduction of EOZ compared to POZ was 13.60%±4.75; a positive correlation between preoperative SE and percent reduction of EOZ was found (r=0.63). For LASIK, mean preoperative SE was -5.89±2.14 D; mean POZ was 6.57±0.34 mm; EOZ 5.16±0.53 mm; the mean difference between POZ and EOZ was 1.41±0.35 mm (p=0.00); the mean reduction of EOZ compared to POZ was 21.46%±5.20. The mean difference between EOZ of the 2 procedures was 0.39 mm (p=0.0008). The mean difference between the reduction in optical zone (POZ-EOZ) of the 2 procedures was -0.53 (p=0.00). In conclusion, in myopia with low astigmatism, the CLEAR application for lenticule extraction provided a limited reduction in EOZ, compared with existing platforms. A positive correlation exists between corrected SE and reduction of the EOZ.","PeriodicalId":17981,"journal":{"name":"Laser therapy","volume":"70 5","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laser therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/ltj.2023.326","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Laser vision correction of myopia induces an effective optical zone (EOZ) smaller than the programmed optical zone (POZ) by 16 to 26%. We evaluated the EOZ after corneal lenticule extraction for myopia with astigmatism ≤1 diopter (D) with a new femtosecond laser application (CLEAR), compared to POZ in a retrospective, consecutive, comparative case series study. Forty eyes of 40 patients underwent lenticule extraction with the Ziemer CLEAR® application; the control group was composed of 40 eyes of 40 patients receiving myopic femtosecond laser in situ keratomileusis (LASIK); EOZ was calculated on difference tangential maps at 6 months. For lenticule extraction, mean preoperative spherical equivalent (SE) was -6.03±2.48 D; mean POZ was 6.43±0.27 mm; EOZ 5.55±0.45 mm; mean difference between POZ and EOZ was 0.88 ± 0.28 mm (p=0.00); the mean reduction of EOZ compared to POZ was 13.60%±4.75; a positive correlation between preoperative SE and percent reduction of EOZ was found (r=0.63). For LASIK, mean preoperative SE was -5.89±2.14 D; mean POZ was 6.57±0.34 mm; EOZ 5.16±0.53 mm; the mean difference between POZ and EOZ was 1.41±0.35 mm (p=0.00); the mean reduction of EOZ compared to POZ was 21.46%±5.20. The mean difference between EOZ of the 2 procedures was 0.39 mm (p=0.0008). The mean difference between the reduction in optical zone (POZ-EOZ) of the 2 procedures was -0.53 (p=0.00). In conclusion, in myopia with low astigmatism, the CLEAR application for lenticule extraction provided a limited reduction in EOZ, compared with existing platforms. A positive correlation exists between corrected SE and reduction of the EOZ.